SEPARATE ACQUISITION REST THALLIUM-201/STRESS TC-99M SESTAMIBI DUAL-ISOTOPE MYOCARDIAL PERFUSION SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY - A CLINICAL VALIDATION-STUDY

被引:448
作者
BERMAN, DS
KIAT, H
FRIEDMAN, JD
WANG, FP
VANTRAIN, K
MATZER, L
MADDAHI, J
GERMANO, G
机构
[1] CEDARS SINAI MED CTR,DEPT MED,DIV CARDIOL,LOS ANGELES,CA
[2] UNIV CALIF LOS ANGELES,SCH MED,DEPT MED,LOS ANGELES,CA 90024
关键词
D O I
10.1016/0735-1097(93)90557-H
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. This study assessed the validity of a novel approach to myocardial perfusion scintigraphy that provides the opportunity to avoid the drawbacks of standard same-day rest/stress technetium-99m sestamibi myocardial perfusion studies by using separate-acquisition dual isotope rest thallium-201 and exercise technetium-99m sestamibi single photon emission computed tomography (SPECT). Background. Standard same day rest/stress technetium-99m sestamibi myocardial perfusion studies are cumbersome, associated with a potential decrease in perceived stress defect severity, compared with thallium-201 due to the presence of rest technetium-99m sestamibi and may be unable to differentiate hibernating from infarcted myocardium. Methods. The dual-isotope procedure was performed in 63 patients without previous myocardial infarction undergoing coronary angiography to evaluate sensitivity and specificity for coronary artery disease and in 107 patients with a low (<5%) likelihood of coronary artery disease to evaluate normalcy rate. To validate defect reversibility, the dual-isotope SPECT study was compared with stress/rest technetium-99m sestamibi SPECT studies in a separate group of 31 patients with previous documented myocardial infarction who underwent a rest technetium-99m sestamibi study in addition to the dual isotope SPECT study. Results. In angiographic correlations, dual-isotope SPECT demonstrated high sensitivity for detecting patients with greater than or equal to 50% stenosis (91%, 55 patients) and greater than or equal to 70% stenosis (96%, 52 patients). In a small group of patients, high specificity was also observed (75% for <50% stenosis [8 patients] and 82% for <70% stenosis [11 patients]). A very high normalcy rate of 95% was also found. In the patient group assessed for defect reversibility, in zones with no previous myocardial infarction, segmental agreement for defect type between rest thallium-201 and rest technetium-99m sestamibi studies was 97% (kappa = 0.79, p < 0.001). In myocardial infarct zones, segmental agreement for defect type was 98% (kappa = 0.93, p < 0.001). Image quality was generally good to excellent. Conclusions. Our findings demonstrate that separate-acquisition dual-isotope myocardial perfusion SPECT is accurate for coronary artery disease detection, correlates well with rest-stress sestamibi studies for assessment of defect reversibility and results in good to excellent image quality. This approach provides an excellent method for the combined assessment of stress myocardial perfusion and myocardial viability.
引用
收藏
页码:1455 / 1464
页数:10
相关论文
共 37 条
  • [1] AGREEMENT IN HUMAN INTERPRETATION OF ANALOG THALLIUM MYOCARDIAL PERFUSION IMAGES
    ATWOOD, JE
    JENSEN, D
    FROELICHER, V
    WITZTUM, K
    GERBER, K
    GILPIN, E
    ASHBURN, W
    [J]. CIRCULATION, 1981, 64 (03) : 601 - 609
  • [2] BERGER BC, 1979, CIRCULATION, V60, P114
  • [3] TECHNETIUM 99M SESTAMIBI IN THE ASSESSMENT OF CHRONIC CORONARY-ARTERY DISEASE
    BERMAN, DS
    KIAT, H
    VANTRAIN, K
    GARCIA, E
    FRIEDMAN, J
    MADDAHI, J
    [J]. SEMINARS IN NUCLEAR MEDICINE, 1991, 21 (03) : 190 - 212
  • [4] BERMAN DS, 1991, CIRCULATION S, V84, P17
  • [5] BERMAN DS, 1984, FREEMAN JOHNSONS CLI, P79
  • [6] BLOOD DK, 1981, CIRCULATION, V58, P777
  • [7] QUANTITATIVE EXERCISE TL-201 ROTATIONAL TOMOGRAPHY FOR EVALUATION OF PATIENTS WITH PRIOR MYOCARDIAL-INFARCTION
    CHOURAQUI, P
    MADDAHI, J
    OSTRZEGA, E
    VANTRAIN, K
    CHARUZI, Y
    PRIGENT, F
    BERMAN, DS
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (02) : 151 - 157
  • [8] INCOMPLETE REDISTRIBUTION IN DELAYED TL-201 SINGLE PHOTON-EMISSION COMPUTED TOMOGRAPHIC (SPECT) IMAGES - AN OVERESTIMATION OF MYOCARDIAL SCARRING
    CLONINGER, KG
    DEPUEY, EG
    GARCIA, EV
    ROUBIN, GS
    ROBBINS, WL
    NODY, A
    DEPASQUALE, EE
    BERGER, HJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 12 (04) : 955 - 963
  • [9] ANALYSIS OF PROBABILITY AS AN AID IN THE CLINICAL-DIAGNOSIS OF CORONARY-ARTERY DISEASE
    DIAMOND, GA
    FORRESTER, JS
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1979, 300 (24) : 1350 - 1358
  • [10] MYOCARDIAL CLEARANCE OF TC-99M HEXAKIS-2-METHOXY-2-METHYLPROPYL ISONITRILE (MIBI) IN PATIENTS WITH CORONARY-ARTERY DISEASE
    FRANCESCHI, M
    GUIMOND, J
    ZIMMERMAN, RE
    PICARD, MV
    ENGLISH, RJ
    CARVALHO, PA
    TUMEH, SS
    HOLMAN, BL
    [J]. CLINICAL NUCLEAR MEDICINE, 1990, 15 (05) : 307 - 312