EFFECTS OF RTC-SILICONE MAXILLOFACIAL PROSTHETIC ELASTOMERS ON CELL-CULTURES

被引:8
作者
POLYZOIS, GL [1 ]
HENSTENPETTERSEN, A [1 ]
KULLMAN, A [1 ]
机构
[1] SCANDINAVIAN INST DENT MAT,NIOM,HASLUM,NORWAY
关键词
D O I
10.1016/0022-3913(94)90191-0
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The use of a wide variety of materials in the construction of maxillofacial prostheses makes biocompatibility testing a necessity. However, the dental literature contains few reports of biocompatibility testing of maxillofacial prosthetic materials. The cytotoxic profiles of five room-temperature cross-linking (RTC)-silicone elastomers were investigated by means of two in vitro cell culture techniques. Mouse fibroblast cells (L929) were used, and the results indicated that RTC-silicone elastomers adversely affected cells in culture and that storage of samples for 1 week in saline solution did not alter this effect. Clinical follow-up of patients wearing prostheses made of these silicone materials is warranted to evaluate host reactions in long-term contact with human mucous membrane and skin tissue.
引用
收藏
页码:505 / 510
页数:6
相关论文
共 31 条
[1]  
CHALIAN VA, 1982, BIOCOMPATIBILITY DEN, V4, P247
[2]   ELASTOMERS FOR MAXILLOFACIAL APPLICATIONS [J].
CRAIG, RG ;
KORAN, A ;
YU, R .
BIOMATERIALS, 1980, 1 (02) :112-117
[3]   TOXICITY OF METHYL-SUBSTITUTED ALCOHOLS AND HALOGEN-SUBSTITUTED ALCOHOLS IN TISSUE-CULTURE RELATIVE TO STRUCTURE - ACTIVITY MODELS AND ACUTE TOXICITY IN MICE [J].
DILLINGHAM, EO ;
MAST, RW ;
BASS, GE ;
AUTIAN, J .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1973, 62 (01) :22-30
[4]  
GRASSO R, 1973, FD COSMET TOXICOL, V11, P255
[5]   TOXICITY TESTING OF MEDICAL DEVICE MATERIALS TESTED IN HUMAN-TISSUE CULTURES [J].
HAUSTVEIT, G ;
TORHEIM, B ;
FYSTRO, D ;
EIDEM, T ;
SANDVIK, MS .
BIOMATERIALS, 1984, 5 (02) :75-80
[6]   ASSESSMENT OF INVITRO CYTO-TOXICITY OF 4 RTV-SILICONE ELASTOMERS USED FOR MAXILLOFACIAL PROSTHESES [J].
HENSTENPETTERSEN, A ;
HULTERSTROM, A .
ACTA ODONTOLOGICA SCANDINAVICA, 1980, 38 (03) :163-167
[7]  
HOWELL R E, 1989, Journal of Dental Research, V68, P909
[8]   BIOCOMPATIBILITY TEST PROCEDURES FOR MATERIALS EVALUATION INVITRO .1. COMPARATIVE TEST SYSTEM SENSITIVITY [J].
JOHNSON, HJ ;
NORTHUP, SJ ;
SEAGRAVES, PA ;
GARVIN, PJ ;
WALLIN, RF .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1983, 17 (04) :571-586
[9]  
Kawahara H, 1982, J Dent Assoc S Afr, V37, P823
[10]   SURFACE-TOPOGRAPHY OF SILICONE-RUBBER PROSTHETIC MATERIALS FABRICATED USING CONVENTIONAL PROCESSING TECHNIQUES [J].
KENT, K ;
ZEIGEL, RF .