MEASUREMENTS OF THE STAPES SUPERSTRUCTURE

被引:24
作者
AWENGEN, DF [1 ]
NISHIHARA, S [1 ]
KUROKAWA, H [1 ]
GOODE, RL [1 ]
机构
[1] STANFORD UNIV,SCH MED,DIV OTOLARYNGOL HEAD & NECK SURG,PALO ALTO,CA
关键词
ANATOMY; HUMAN; MEASUREMENT; MIDDLE EAR; MORPHOLOGY; STAPES;
D O I
10.1177/000348949510400411
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Ten human stapes from fresh temporal bones were measured to obtain relevant distances of the stapes superstructure. The dimensions of the parts of the superstructure are as follows: 1) stapes head 1.14 me (range, 0.91 to 1.49) in diameter parallel to the axis of the footplate and 0.83 mm (range, 0.65 to 1.08) perpendicular to it; 2) stapes head to shoulders 0.93 mm (range, 0.81 to 1.07), head to foramen 1.26 mm (range, 1.15 to 1.39), and head to lateral. surface of stapes footplate 3.19 mm (range, 2.91 to 3.45); 3) neck width parallel to the axis of the footplate 1.18 mm (range, 0.88 to 1.47) and 0.64 mm (range, 0.48 to 0.88) perpendicular to it; 4) anterior crus 0.58 mm wide (range, 0.41 to 0.74) at the shoulder of the arch and 0.51 mm (range, 0.39 to 0.65) closer to the stapes footplate; 5) posterior crus 0.65 mm wide (range, 0.46 to 0.77) at the shoulder of the arch and 0.55 mm (range, 0.38 to 0.75) closer to the stapes footplate; and 6) maximum width of entire superstructure near footplate 2.48 mm (range, 2.06 to 2.98).
引用
收藏
页码:311 / 316
页数:6
相关论文
共 19 条
[1]  
AWENGEN DF, 1992, EUR ARCH OTO-RHINO-L, V249, P1
[2]  
AWENGEN DF, 1991, LONG-TERM RESULTS AND INDICATIONS IN OTOLOGY AND OTONEUROSURGERY, P269
[3]  
AWENGEN DF, 1991, REV OFFICIELLE SOC F, V7, P27
[4]  
Djeric D, 1988, Ann Otolaryngol Chir Cervicofac, V105, P313
[5]  
DONALDSON JA, 1992, SURGICAL ANATOMY TEM
[6]  
Gundersen T., 1971, PROSTHESES OSSICULAR
[7]  
Horiuchi Y, 1989, Nihon Jibiinkoka Gakkai Kaiho, V92, P383
[8]  
Hough JVD, 1961, MALFORMATIONS ANATOM
[9]  
Kirikae I., 1959, STRUCTURE FUNCTION M
[10]   HEARING RESULTS WITH CLOTHESPIN OSSICULOPLASTY - PRELIMINARY-REPORT ON THE KRAUS MODIFIED SCHURING OSSICLE-CUP PROSTHESIS (CLOTHESPIN PROSTHESIS) [J].
KRAUS, EM .
OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1993, 109 (01) :26-34