Polymer coated quartz crystal microbalance sensors for the detection of volatile organic compounds

被引:0
作者
Bougharouat, Ali [1 ]
Bellel, Azzedine [1 ]
Sahli, Salah [2 ]
Segui, Yvan [3 ]
Raynaud, Patrice [3 ]
机构
[1] Univ Mentouri Constantine, Fac Sci Ingenieur, Lab Etud Mat Elect Applicat Med LEMEAMED, Constantine, Algeria
[2] Univ Mentouri Constantine, Fac Sci Ingenieur, LMI, Constantine, Algeria
[3] Univ Paul Sabatier, Lab Plasmas & Convers Energit LAPLACE, F-31062 Toulouse, France
关键词
Quartz crystal microbalance; TEOS film; Volatile organic compounds; sensor;
D O I
10.12816/0010272
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this work, plasma polymerization of tetraethoxysilane (TEOS) has been used for producing QCM chemical sensors. The sensor was exposed towards the methanol and chloroform molecules. The measured isotherms on modified QCM electrode showed a good reproducibility and reversibility. Generally, the frequency shift OP of QCM increases linearly with the vapor concentration. The evolution of sensor response showed clearly an improvement of the QCM sensibility. However, the film elaborated from 50% of TEOS and 50% of a was found to be significantly more sensitive than film deposited from high proportion of oxygen due to dense structure. Concerning the selectivity, the results revealed a good affinity of the layer to methanol molecules. Fourier transform infrared spectroscopy (Flue) analysis showed that VOCs molecules interact via hydrogen bonding due to the presence of the-OHgroup in the elaborated layers.
引用
收藏
页码:8 / 11
页数:4
相关论文
共 9 条
[1]   POLYANILINE THIN-FILMS FOR GAS-SENSING [J].
AGBOR, NE ;
PETTY, MC ;
MONKMAN, AP .
SENSORS AND ACTUATORS B-CHEMICAL, 1995, 28 (03) :173-179
[2]   Quartz crystal microbalance sensor coated with polyaniline emeraldine base for determination of chlorinated aliphatic hydrocarbons [J].
Ayad, Mohamad M. ;
El-Hefnawey, Gad ;
Torad, Nagy L. .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 134 (02) :887-894
[3]  
Jennifer UBRIG, 2007, THESIS
[4]   Properties of low dielectric constant fluorinated silicon oxide films prepared by plasma enhanced chemical vapor deposition [J].
Kim, K ;
Kwon, D ;
Lee, GS .
THIN SOLID FILMS, 1998, 332 (1-2) :369-374
[5]   Piezoelectric chemical sensors based on morpholine containing polymers [J].
Price, GJ ;
Clifton, AA ;
Burton, VJ ;
Hunter, TC .
SENSORS AND ACTUATORS B-CHEMICAL, 2002, 84 (2-3) :208-213
[6]   VERWENDUNG VON SCHWINGQUARZEN ZUR WAGUNG DUNNER SCHICHTEN UND ZUR MIKROWAGUNG [J].
SAUERBREY, G .
ZEITSCHRIFT FUR PHYSIK, 1959, 155 (02) :206-222
[7]  
Wallace G.G., 2003, CONDUCTIVE ELECTROAC
[8]   Improvement of ultrasonic atomizer method for deposition of gas-sensing film on QCM [J].
Wyszynski, Bartosz ;
Galvez, Agustin Gutierrez ;
Nakamoto, Takamichi .
SENSORS AND ACTUATORS B-CHEMICAL, 2007, 127 (01) :253-259
[9]   Profile of patients with chemical injury and sensitivity [J].
Ziem, G ;
McTamney, J .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1997, 105 :417-436