ELECTROANALYTICAL AND BIOCOMPATIBILITY STUDIES ON MICROFABRICATED ARRAY SENSORS

被引:37
作者
LINDNER, E
COSOFRET, VV
BUCK, RP
JOHNSON, TA
ASH, RB
NEUMAN, MR
KAO, WYJ
ANDERSON, JM
机构
[1] UNIV N CAROLINA,DEPT CHEM,CHAPEL HILL,NC 27599
[2] UNIV N CAROLINA,DEPT MED,CHAPEL HILL,NC 27599
[3] N CAROLINA STATE UNIV,DEPT ELECT & COMP ENGN,RALEIGH,NC 27695
[4] CASE WESTERN RESERVE UNIV,DEPT BIOMED ENGN,CLEVELAND,OH 44106
关键词
BIOCOMPATIBILITY; SENSOR ARRAYS; ION SELECTIVE ELECTRODES; MICROFABRICATION;
D O I
10.1002/elan.1140070913
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
pH, potassium and calcium ion-selective membranes based on neutral ionophores TDDA, valinomycin and ETH-1001, respectively and immobilized in high molecular weight (HMW) and carboxylated poly(vinyl chloride) (PVC-COOH) as well as in aliphatic polyurethane (Tecoflex) matrices with normal and reduced amounts of plasticizers were investigated with respect of their general analytical properties, biocompatibility and cellular responses. The analytical performance of the PVC-COOH based potassium electrodes was not effected by reducing the plasticizer content from 66% (w/w) to 33% (w/w) while that of pH electrodes was significantly deteriorated at the lower plasticizer level. High molecular weight PVC and Tecoflex membranes with low plasticizer content induce less inflammatory response compared to membranes cast with high plasticizer concentrations or PVC-COOH as matrix. o-NPOE plasticized membranes are correlated with an increased acute, but a decreased chronic inflammatory response, when compared to membranes cast with DOS as plasticizer.
引用
收藏
页码:864 / 870
页数:7
相关论文
共 18 条
[1]   LIPOPHILIC SALTS AS MEMBRANE ADDITIVES AND THEIR INFLUENCE ON THE PROPERTIES OF MACROELECTRODES AND MICROELECTRODES BASED ON NEUTRAL CARRIERS [J].
AMMANN, D ;
PRETSCH, E ;
SIMON, W ;
LINDNER, E ;
BEZEGH, A ;
PUNGOR, E .
ANALYTICA CHIMICA ACTA, 1985, 171 (MAY) :119-129
[2]  
ANDERSON JM, 1988, ASAIO, V11, P101
[3]   ANION EFFECTS ON DONNAN FAILURE OF AMINATED-POLY(VINYL CHLORIDE)-BASED AND NEUTRAL-CARRIER-BASED PH SENSORS [J].
BUCK, RP ;
COSOFRET, VV ;
LINDNER, E .
ANALYTICA CHIMICA ACTA, 1993, 282 (02) :273-281
[4]   CARBOXYLATED POLY(VINYL CHLORIDE) AS A SUBSTRATE FOR ION SENSORS - EFFECTS OF NATIVE ION-EXCHANGE ON RESPONSES [J].
COSOFRET, VV ;
BUCK, RP ;
ERDOSY, M .
ANALYTICAL CHEMISTRY, 1994, 66 (21) :3592-3599
[5]   ELECTROANALYTICAL AND BIOCOMPATIBILITY STUDIES ON CARBOXYLATED POLY(VINYL CHLORIDE) MEMBRANES FOR MICROFABRICATED ARRAY SENSORS [J].
COSOFRET, VV ;
ERDOSY, M ;
BUCK, RP ;
KAO, WJ ;
ANDERSON, JM ;
LINDNER, E ;
NEUMAN, MR .
ANALYST, 1994, 119 (11) :2283-2292
[6]  
COSOFRET VV, 1994, ANAL LETT, V27, P15
[7]   FLEXIBLE (KAPTON-BASED) MICROSENSOR ARRAYS OF HIGH-STABILITY FOR CARDIOVASCULAR APPLICATIONS [J].
LINDNER, E ;
COSOFRET, VV ;
UFER, S ;
BUCK, RP ;
KUSY, RP ;
ASH, RB ;
NAGLE, HT .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS, 1993, 89 (02) :361-367
[8]   ION-SELECTIVE MEMBRANES WITH LOW PLASTICIZER CONTENT - ELECTROANALYTICAL CHARACTERIZATION AND BIOCOMPATIBILITY STUDIES [J].
LINDNER, E ;
COSOFRET, VV ;
UFER, S ;
BUCK, RP ;
KAO, WJ ;
NEUMAN, MR ;
ANDERSON, JM .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1994, 28 (05) :591-601
[9]   RESPONSES OF SITE-CONTROLLED, PLASTICIZED MEMBRANE ELECTRODES [J].
LINDNER, E ;
GRAF, E ;
NIEGREISZ, Z ;
TOTH, K ;
PUNGOR, E ;
BUCK, RP .
ANALYTICAL CHEMISTRY, 1988, 60 (04) :295-301
[10]   THE POTENTIOMETRIC PH RESPONSE OF CHROMOIONOPHORES USED IN OPTICAL SENSORS [J].
LINDNER, E ;
ROSATZIN, T ;
JENEY, J ;
COSOFRET, VV ;
SIMON, W ;
BUCK, RP .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1993, 352 (1-2) :309-312