IRON-OXIDE ENHANCED MR-IMAGING OF THE LIVER AND SPLEEN - REVIEW OF THE 1ST-5 YEARS

被引:254
作者
FERRUCCI, JT [1 ]
STARK, DD [1 ]
机构
[1] HARVARD UNIV,SCH MED,BOSTON,MA 02115
关键词
D O I
10.2214/ajr.155.5.2120963
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Superparamagnetic iron oxide (SPIO) particles are a potent new class of MR contrast agents affording improved detection of hepatic and splenic neoplasms. In this report we review the development of this agent through preclinical studies and early clinical results at Massachusetts General Hospital during a 5-year investigation. SPIO particles are sequestered by normal phagocytic Kupffer cells of the reticuloendothelial system (RES) but are not retained in tumor tissue. Consequently, there is a fivefold increase in T2 relaxation between normal RES tissue and tumor, with a comparable advantage in quantitative signal-to-noise ratio, contrast-to-noise ratio, and lesion detectability in the liver and spleen on MR imaging. Increased lesion conspicuity can be exploited to decrease threshold size for lesion detection to less than 3 mm. Clinically beneficial effects occur with a variety of mildly T2-weighted spin-echo pulse sequences; gradient-echo techniques show even greater benefit after administration of SPIO. Metabolically, pharmaceutical-grade preparation are biodegradable and bioavailable, being rapidly turned over into body iron stores and incorporated into erythrocyte hemoglobin. Early dose-escalation clinical trials have identified a probable clinical dose range of 10-20 μmol Fe/kg body weight. In the United States, SPIO compounds evaluated to date are still approved for use in investigation studies only. Newer commercial formulations currently being evaluated may extend clinical safety margins.
引用
收藏
页码:943 / 950
页数:8
相关论文
共 20 条
[1]  
BACON BR, 1987, J LAB CLIN MED, V110, P164
[2]   HYSTERESIS LOOPS OF MIXTURES OF FERROMAGNETIC MICROPOWDERS [J].
BEAN, CP .
JOURNAL OF APPLIED PHYSICS, 1955, 26 (11) :1381-1383
[3]  
BLAKEMORE RP, 1981, SCI AM, V246, P58
[4]   HEPATIC CIRRHOSIS AND HEPATITIS - MR IMAGING ENHANCED WITH SUPERPARAMAGNETIC IRON-OXIDE [J].
ELIZONDO, G ;
WEISSLEDER, R ;
STARK, DD ;
GUERRA, J ;
GARZA, J ;
FRETZ, CJ ;
TODD, LE ;
FERRUCCI, JT .
RADIOLOGY, 1990, 174 (03) :797-801
[5]   SUPERPARAMAGNETIC IRON OXIDE-ENHANCED MR IMAGING - PULSE SEQUENCE OPTIMIZATION FOR DETECTION OF LIVER-CANCER [J].
FRETZ, CJ ;
ELIZONDO, G ;
WEISSLEDER, R ;
HAHN, PF ;
STARK, DD ;
FERRUCCI, JT .
RADIOLOGY, 1989, 172 (02) :393-397
[6]   DETECTION OF HEPATIC METASTASES - COMPARISON OF CONTRAST-ENHANCED CT, UNENHANCED MR IMAGING, AND IRON-OXIDE ENHANCED MR IMAGING [J].
FRETZ, CJ ;
STARK, DD ;
METZ, CE ;
ELIZONDO, G ;
WEISSLEDER, R ;
SHEN, JH ;
WITTENBERG, J ;
SIMEONE, J ;
FERRUCCI, JT .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 155 (04) :763-770
[7]   CLINICAL-APPLICATION OF SUPERPARAMAGNETIC IRON-OXIDE TO MR IMAGING OF TISSUE PERFUSION IN VASCULAR LIVER-TUMORS [J].
HAHN, PF ;
STARK, DD ;
WEISSLEDER, R ;
ELIZONDO, G ;
SAINI, S ;
FERRUCCI, JT .
RADIOLOGY, 1990, 174 (02) :361-366
[8]   USE OF MAGNETITE PARTICLES AS A CONTRAST AGENT FOR MR IMAGING OF THE LIVER [J].
KAWAMURA, Y ;
ENDO, K ;
WATANABE, Y ;
SAGA, T ;
NAKAI, T ;
HIKITA, H ;
KAGAWA, K ;
KONISHI, J .
RADIOLOGY, 1990, 174 (02) :357-360
[9]   DETECTION OF LIVER METASTASES WITH SUPERPARAMAGNETIC IRON-OXIDE IN 15 PATIENTS - RESULTS OF MR IMAGING AT 1.5-T [J].
MARCHAL, G ;
VANHECKE, P ;
DEMAEREL, P ;
DECROP, E ;
KENNIS, C ;
BAERT, AL ;
VANDERSCHUEREN, E .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (04) :771-775
[10]   POTENTIAL MR PITFALL IN RELYING ON LESION LIVER INTENSITY RATIO IN PRESENCE OF HEPATIC HEMOCHROMATOSIS [J].
MIROWITZ, S ;
HEIKEN, JP ;
LEE, JKT .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1988, 12 (02) :323-324