An Evaluation of Two Approaches to Skin Bolus Design for Patients Receiving Radiotherapy for Head and Neck Cancers

被引:4
作者
Luu, Andrew [1 ,2 ]
Doerwald-Munoz, Lilian [1 ]
Ostapiak, Orest [1 ,2 ]
机构
[1] Juravinski Canc Ctr, Dept Radiat Therapy, Hamilton, ON, Canada
[2] McMaster Univ, Dept Med Phys & Appl Radiat Sci, Hamilton, ON, Canada
关键词
Bolus; dosimetry; head and neck cancer; radiation therapy; radiotherapy;
D O I
10.1016/j.jmir.2014.08.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This radiation treatment planning study compares two approaches to designing a bolus for patients with head and neck cancer. Our current approach, based on clinical examination, is compared with an alternative approach, based on the patient's computed tomographic image data set, to investigate potential improvements in delivering the prescribed dose to the superficial regions of the clinical target volume (CTV) while limiting the dose to normal skin. Methods: Twelve consecutive head and neck radiotherapy plans requiring a bolus were selected. A clinically placed bolus was designed by a radiation oncologist through physical examination of the patient. A virtual bolus was designed using an algorithm that configured it to overlay only the superficial CTV delineated on the patient's CT data set. These two approaches were compared on the basis of dose-volume histograms of normal skin and the superficial CTV, as well as the total bolus area. Results: Of 12 patients, the virtual bolus plan resulted in a decrease in the bolus area of at least 4 cm 2 for nine patients, an increase in the bolus area of at least 30 cm 2 for three patients, and an improvement in the minimum dose to the superficial CTV in six patients. Of these six patients, half had a reduction in the bolus area with a corresponding modest 2% improvement in the minimum dose to the superficial CTV, whereas the other half had an increase in the bolus area with a corresponding dramatic 10%-57% improvement in the minimum dose to the superficial CTV. Conclusions: Basing bolus design on computed tomography image data rather than on clinical examination reduced the area of normal skin under the bolus in 9 patients (75%) and improved dose coverage of the superficial CTV in 3 patients (25%). All plans benefited from the virtual bolus approach because it has been shown to be more appropriate for balancing skin sparing with target coverage.
引用
收藏
页码:S37 / S42
页数:6
相关论文
共 9 条
[1]   Effects on skin dose from unwanted air gaps under bolus in photon beam radiotherapy [J].
Butson, MJ ;
Cheung, T ;
Yu, P ;
Metcalfe, P .
RADIATION MEASUREMENTS, 2000, 32 (03) :201-204
[2]  
Khan Y., 2013, J CANC THER, V04, P1251, DOI [DOI 10.4236/JCT.2013.47147, 10.4236/jct.2013.47147]
[3]   Skin toxicity due to intensity-modulated radiotherapy for head-and-neck carcinoma [J].
Lee, N ;
Chuang, C ;
Quivey, JM ;
Phillips, TL ;
Akazawa, P ;
Verhey, LJ ;
Xia, P .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (03) :630-637
[4]   A highly reproducible Bolus immobilization technique for the treatment of scalp malignancies [J].
Lin, Steven H. ;
Latronico, Diane ;
Teslow, Terrance ;
Bajaj, Gopal K. .
MEDICAL DOSIMETRY, 2008, 33 (01) :30-35
[5]   The potential for dose dumping in normal tissues with IMRT for pelvic and H&N cancers [J].
Reddy, Nandanuri M. S. ;
Mazur, Andrzej K. ;
Sampath, Seshadri ;
Osian, Adrian ;
Sood, Brij M. ;
Ravi, Akkamma ;
Nori, Dattatreyudu .
MEDICAL DOSIMETRY, 2008, 33 (01) :55-61
[6]  
Rustgi A K, 1997, Med Dosim, V22, P95, DOI 10.1016/S0958-3947(97)00001-0
[7]   The influence of the bolus-surface distance on the dose distribution in the build-up region [J].
Sroka, Martyna ;
Regula, Jakub ;
Lobodziec, Wlodzimierz .
REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2010, 15 (06) :161-164
[8]   The effect of optimization on surface dose in intensity modulated radiotherapy (IMRT) [J].
Thomas, SJ ;
Hoole, ACF .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (21) :4919-4928
[9]   On bolus for megavoltage photon and electron radiation therapy [J].
Vyas, Vedang ;
Palmer, Lisa ;
Mudge, Ray ;
Jiang, Runqing ;
Fleck, Andre ;
Schaly, Bryan ;
Osei, Ernest ;
Charland, Paule .
MEDICAL DOSIMETRY, 2013, 38 (03) :268-273