COMPLEX PERMITTIVITY MEASUREMENTS OF THE COLORADO POTATO BEETLE USING COAXIAL PROBE TECHNIQUES

被引:0
|
作者
COLPITTS, B
PELLETIER, Y
COGSWELL, S
机构
关键词
COLORADO POTATO BEETLE; POTATO PLANT; COMPLEX PERMITTIVITY; COAXIAL PROBE; MICROWAVE; MEASUREMENT;
D O I
暂无
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Examining the effectiveness of microwave energy for control of the Colorado potato beetle (CPB) in potato crops begins with an investigation of the dielectric properties of the insect and plant. This paper presents the measured complex permittivity of the CPB and potato plant over the frequency range 100 MHz to 26.5 GHz obtained using coaxial probes and an automatic network analyzer. Specific measurements include the beetle prothorax, thorax, and abdomen as well as the plant leaflet, petiole and stem. An RMS error of less than 0.79 is obtained for both the real and imaginary permittivity over the band for measurements of 0.1 M saline, similar errors are expected for the biological samples.
引用
收藏
页码:175 / 182
页数:8
相关论文
共 50 条
  • [31] MANAGEMENT OF THE COLORADO POTATO BEETLE USING THE ENTOMOGENOUS FUNGUS BEAUVERIA-BASSIANA
    CAMPBELL, RK
    ANDERSON, TE
    SEMEL, M
    ROBERTS, DW
    AMERICAN POTATO JOURNAL, 1985, 62 (01): : 29 - 37
  • [32] Complex Dielectric Permittivity Measurements Using a Rational Functional Method with Arbitrary Open-Ended Coaxial Probes
    Dilman, Ismail
    Akinci, Mehmet Nuri
    Cayoren, Mehmet
    2021 29TH TELECOMMUNICATIONS FORUM (TELFOR), 2021,
  • [33] COMPLEX PERMITTIVITY AND PERMEABILITY ESTIMATION BY REFLECTION MEASUREMENTS OF OPEN AND SHORT COAXIAL TRANSMISSION LINE
    Staszek, Kamil
    Gruszczynski, Slawomir
    Wincza, Krzysztof
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2014, 56 (03) : 727 - 732
  • [34] Broadband measurement of complex permittivity using reflection method and coaxial probes
    Zajicek, Radim
    Oppl, Ladislav
    Vrba, Jan
    RADIOENGINEERING, 2008, 17 (01) : 14 - 19
  • [35] Measurement of Complex Permittivity for Liquids Using the Coaxial Line Reflection Method
    Shibata, Kouji
    Kobayashi, Masaki
    2015 ASIA-PACIFIC INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (APEMC), 2015, : 452 - 455
  • [36] An efficient model of an open-ended coaxial-line probe for measuring the complex permittivity
    Shin, H
    Hyun, SY
    Kim, SW
    Kim, SY
    SUBSURFACE SENSING TECHNOLOGIES AND APPLICATIONS II, 2000, 4129 : 332 - 339
  • [37] ULTRASTRUCTURE OF THE SENSORY COMPLEX ON THE MAXILLARY AND LABIAL PALPI OF THE COLORADO POTATO BEETLE, LEPTINOTARSA-DECEMLINEATA
    SEN, A
    JOURNAL OF MORPHOLOGY, 1988, 195 (02) : 159 - 175
  • [38] Permittivity measurements up to 30 GHz using micromachined probe
    Kim, JM
    Oh, DH
    Park, JH
    Cho, JW
    Kwon, YW
    Cheon, CY
    Kim, YK
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2005, 15 (03) : 543 - 550
  • [39] Measurement and hemodialysis effect of complex relative permittivity for blood of kidney patients using open-ended coaxial measurement probe
    Takeda, Akira
    Takata, Kazuyuki
    Nagao, Hirotomo
    Wang, Jianqing
    Fujiwara, Osamu
    ELECTRONICS AND COMMUNICATIONS IN JAPAN, 2012, 95 (12) : 56 - 61
  • [40] PERMITTIVITY MEASUREMENTS ON LOW AND MEDIUM LOS LIQUIDS USING A TERMINATED COAXIAL LINE
    JORDAN, BP
    GRANT, EH
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1970, 3 (07) : 1068 - &