Design of Timber-Concrete Composite Floors for Fire Resistance

被引:22
作者
O'Neill, James W. [1 ]
Carradine, David [1 ]
Moss, Peter J. [1 ]
Fragiacomo, Massimo [2 ]
Dhakal, Rajesh [1 ]
Buchanan, Andrew H. [1 ]
机构
[1] Univ Canterbury, Dept Civil & Nat Resources Engn, Private Bag 4800, Christchurch 8140, New Zealand
[2] Univ Sassari, Dept Architecture & Planning, I-07041 Alghero, Italy
关键词
composite; concrete; connection; fire resistance; LVL; timber;
D O I
10.1260/2040-2317.2.3.231
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This research investigated the fire performance and failure behaviour of timber-concrete composite floor systems currently under development in New Zealand, resulting in a design method for evaluating the fire resistance of these floors with different types of connections. Furnace tests were performed on two full-size floor specimens at the Building Research Association of New Zealand (BRANZ). Both floor specimens were 4 m long and 3 m wide, consisting of 65 mm concrete topping on plywood formwork, connected to double LVL (laminated veneer lumber) floor joists. They were tested over a 4 m span, subjected to a nominal design live load of 2.5 kPa. Both floors were subjected to the ISO 834 test fire for over 60 minutes. Two separate connection types were tested; concrete notches cut into the timber beams with an incorporated shear key, and metal toothed plates pressed between the double beams. It was found that the reduction in section of the timber beams due to the fire governed the failure mode of the floors. The test data and visual observations aided in the development of an analytical model for evaluating the fire resistance of timber-concrete composite floors. This was implemented into a spreadsheet that is able to predict the expected fire resistance of these floors, taking into account some major time dependent variable properties that can have an effect on the overall performance. Load-span tables have been produced to give the estimated fire resistance of floors with differing dimensions, span lengths and applied loads.
引用
收藏
页码:231 / 242
页数:12
相关论文
共 50 条
  • [1] A design model for the fire resistance of timber-concrete composite slabs
    Frangi, A
    Fontana, M
    INNOVATIVE WOODEN STRUCTURES AND BRIDGES, 2001, : 113 - 118
  • [2] Prefabricated timber-concrete composite floors
    T. Sartori
    R. Crocetti
    European Journal of Wood and Wood Products, 2016, 74 : 483 - 485
  • [3] Fire Design of Timber-Concrete Composite Slabs with Screwed Connections
    Frangi, Andrea
    Knobloch, Markus
    Fontana, Mario
    JOURNAL OF STRUCTURAL ENGINEERING, 2010, 136 (02) : 219 - 228
  • [4] Analytical and Numerical Verification of Vibration Design in Timber Concrete Composite Floors
    Perkovic, Nikola
    Rajcic, Vlatka
    Barbalic, Jure
    FORESTS, 2021, 12 (06):
  • [5] Literature Review on Timber-Concrete Composite Structures in Fire
    Hozjan, Tomaz
    Bedon, Chiara
    Ogrin, Anita
    Cvetkovska, Meri
    Klippel, Michael
    JOURNAL OF STRUCTURAL ENGINEERING, 2019, 145 (11)
  • [6] Design and realization of composite timber-concrete beams
    Kvocak, V.
    Al Ali, M.
    ADVANCES AND TRENDS IN ENGINEERING SCIENCES AND TECHNOLOGIES II, 2017, : 183 - 186
  • [7] Fire behaviour of timber-concrete composite slabs using beech
    Klingsch, Eike
    Klippel, Michael
    Boccadoro, Lorenzo
    Frangi, Andrea
    Fontana, Mario
    BAUTECHNIK, 2015, 92 (05) : 323 - 329
  • [8] Fundamental Behavior of Timber Concrete-Composite Floors in Fire
    Shephard, Annabel B.
    Fischer, Erica C.
    Barbosa, Andre R.
    Sinha, Arijit
    JOURNAL OF STRUCTURAL ENGINEERING, 2021, 147 (02)
  • [9] Tangential behavior of nailed composite timber-concrete floor structures
    Taazount, M.
    Amziane, S.
    Molard, D.
    CONSTRUCTION AND BUILDING MATERIALS, 2013, 40 : 506 - 513
  • [10] Timber-concrete composites (TCC) floors subjected to hogging moment
    Hammad, M. W.
    Valipour, H. R.
    Foster, S. J.
    ENGINEERING STRUCTURES, 2024, 303