BEAM DEFLECTION FOR TEMPORAL ENCODING IN TIME-OF-FLIGHT MASS-SPECTROMETRY

被引:18
作者
YEFCHAK, GE
SCHULTZ, GA
ALLISON, J
ENKE, CG
HOLLAND, JF
机构
[1] MICHIGAN STATE UNIV,DEPT CHEM,E LANSING,MI 48824
[2] MICHIGAN STATE UNIV,DEPT BIOCHEM,E LANSING,MI 48824
基金
美国国家卫生研究院;
关键词
D O I
10.1016/1044-0305(90)85027-J
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The pulsed ion sources used in conventional time-of-flight mass spectrometry (TOFMS) generally do not provide adequate resolving power across the mass range required for applications such as gas chromatography combined with mass spectrometry (GC/MS). Theoretical and experimental aspects of beam deflection techniques, which provide time encoding for TOFJMS with continuous ions sources, are explored here. In this approach, ion source conditions do not affect resolving power, allowing for a greater variety of ionization modes to be used. Theoretical predictions for the resolving power attainable with beam deflection, which are satisfactory for GC/MS applications, agree well with experimentally determined values. The combination of GC-beam deflection-TOFMS with time-array detection is evaluated, and the capabilities of this system are compared to those of scanning mass spectrometers. © 1990 American Society for Mass Spectrometry.
引用
收藏
页码:440 / 447
页数:8
相关论文
共 50 条
  • [41] TIME-OF-FLIGHT SECONDARY ION MASS-SPECTROMETRY OF POLYMER MATERIALS
    VANLEYEN, D
    HAGENHOFF, B
    NIEHUIS, E
    BENNINGHOVEN, A
    BLETSS, IV
    HERCULES, DM
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1989, 7 (03): : 1790 - 1794
  • [42] RECENT DEVELOPMENTS IN TECHNIQUES UTILIZING TIME-OF-FLIGHT MASS-SPECTROMETRY
    PRICE, D
    MILNES, GJ
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1984, 60 (SEP) : 61 - 81
  • [43] TIME-OF-FLIGHT SECONDARY ION MASS-SPECTROMETRY OF PERFLUORINATED POLYETHERS
    BLETSOS, IV
    HERCULES, DM
    FOWLER, D
    VANLEYEN, D
    BENNINGHOVEN, A
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1990, 200 : 7 - FLUO
  • [44] HOT CELL-BASED TIME-OF-FLIGHT MASS-SPECTROMETRY
    FRANK, SM
    BUNNELL, DJ
    CARNEY, KP
    JOHNSON, SG
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1995, 194 (01): : 35 - 39
  • [45] EXTRACTION PULSE-GENERATOR FOR TIME-OF-FLIGHT MASS-SPECTROMETRY
    LOBODA, AV
    DODONOV, AF
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (09) : 4740 - 4741
  • [46] ION-OPTICAL SOLUTIONS IN TIME-OF-FLIGHT MASS-SPECTROMETRY
    IOANOVICIU, D
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1995, 9 (11) : 985 - 997
  • [47] LASER-ASSISTED REFLECTRON TIME-OF-FLIGHT MASS-SPECTROMETRY
    MAMYRIN, BA
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1994, 131 : 1 - 19
  • [48] SURFACE INDUCED DISSOCIATION FOR TANDEM TIME-OF-FLIGHT MASS-SPECTROMETRY
    WILLIAMS, ER
    FANG, LL
    ZARE, RN
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1993, 123 (03): : 233 - 241
  • [49] TIME-OF-FLIGHT RESONANCE IONIZATION MASS-SPECTROMETRY (RIMS) OF NI
    ROTHSCHOPF, G
    LEWIS, R
    ESTLER, R
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1993, 205 : 214 - CHED
  • [50] ANALYSIS OF COMBUSTION PRODUCTS USING TIME-OF-FLIGHT MASS-SPECTROMETRY
    LOEPFE, M
    BURTSCHER, H
    SIEGMANN, HC
    WATER AIR AND SOIL POLLUTION, 1993, 68 (1-2) : 177 - 184