Ventilation Control of Indoor Transmission of Airborne Diseases in an Urban Community

被引:34
|
作者
Gao, Xiaolei [1 ]
Li, Yuguo [1 ]
Leung, Gabriel M. [2 ]
机构
[1] Univ Hong Kong, Dept Mech Engn, Hong Kong, Hong Kong, Peoples R China
[2] Univ Hong Kong, Dept Community Med, Pokfulam, Hong Kong, Peoples R China
关键词
Airborne disease; Engineering control; Ventilation; Wells-Riley equation; SEIR model; Influenza; ULTRAVIOLET GERMICIDAL IRRADIATION; UPPER-ROOM AIR; MATHEMATICAL-THEORY; ROYAL SOCIETY; RESIDENTIAL BUILDINGS; INFLUENZA-A; INFECTION; MODEL; RISK; TUBERCULOSIS;
D O I
10.1177/1420326X09104141
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Following the recent severe acute respiratory syndrome epidemics and worldwide concern about the next pandemic, whether influenza or multiple drug resistant tuberculosis, has underlined the importance of effective interventions into airborne disease transmission in indoor environments in a community. The engineering control measures available include ventilation dilution, use of high-efficiency particulate air filters in a room or in the heating, ventilation, and air-conditioning (HVAC) system, and use of ultraviolet germicidal irradiation devices in ceiling area of a room or in the HVAC system. These methods are known to be effective in controlling or delaying airborne disease transmission in a single enclosure in both healthcare facilities and the community. However, there have been no studies of their relative effectiveness at the community level. This paper presents mathematical modeling of some engineering control strategies with a focus on ventilation and corresponding analysis of their relative effectiveness compared with other public health interventions in disease control in indoor environments at the community level. The results should help us to determine the most effective intervention strategies. We conclude that the engineering intervention methods such as building ventilation can be as effective as public health interventions and the ventilation rates specified in the existing standards such as ASHRAE 62 may be too low for the purpose of preventing or controlling airborne infectious diseases in indoor environments.
引用
收藏
页码:205 / 218
页数:14
相关论文
共 50 条
  • [41] Control of airborne infectious diseases in ventilated spaces
    Nielsen, Peter V.
    JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2009, 6 : S747 - S755
  • [42] A review on indoor airborne transmission of COVID-19- modelling and mitigation approaches
    Rayegan, Saeed
    Shu, Chang
    Berquist, Justin
    Jeon, Jisoo
    Zhou, Liang
    Wang, Liangzhu
    Mbareche, Hamza
    Tardif, Patrique
    Ge, Hua
    JOURNAL OF BUILDING ENGINEERING, 2023, 64
  • [43] Sensitivity of airborne transmission of enveloped viruses to seasonal variation in indoor relative humidity
    Robey, Alison J.
    Fierce, Laura
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2022, 130
  • [44] Personalized ventilation as a control measure for airborne transmissible disease spread
    Pantelic, Jovan
    Sze-To, Gin Nam
    Tham, Kwok Wai
    Chao, Christopher Y. H.
    Khoo, Yong Chuan Mike
    JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2009, 6 : S715 - S726
  • [45] Risk of indoor airborne infection transmission estimated from carbon dioxide concentration
    Rudnick, SN
    Milton, DK
    INDOOR AIR, 2003, 13 (03) : 237 - 245
  • [46] APPLICATION OF STOCHASTIC PETRI NETS FOR MODELLING THE TRANSMISSION OF AIRBORNE INFECTION IN INDOOR ENVIRONMENT
    Wang, Gang
    Zhang, Ying
    Shepherd, Simon J.
    Beggs, Clive B.
    Rao, Nini
    ACTA MEDICA MEDITERRANEA, 2016, 32 : 587 - 592
  • [47] Factors involved in the aerosol transmission of infection and control of ventilation in healthcare premises
    Tang, J. W.
    Li, Y.
    Eames, I.
    Chan, P. K. S.
    Ridgway, G. L.
    JOURNAL OF HOSPITAL INFECTION, 2006, 64 (02) : 100 - 114
  • [48] Modeling and multiobjective optimization of indoor airborne disease transmission risk and associated energy consumption for building HVAC systems
    Risbeck, Michael J.
    Bazant, Martin Z.
    Jiang, Zhanhong
    Lee, Young M.
    Drees, Kirk H.
    Douglas, Jonathan D.
    ENERGY AND BUILDINGS, 2021, 253
  • [49] Intermittent occupancy combined with ventilation: An efficient strategy for the reduction of airborne transmission indoors
    Melikov, A. K.
    Ai, Z. T.
    Markov, D. G.
    SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 744 (744)
  • [50] Indoor Transmission of Respiratory Diseases and Influencing Factors—A Critical Review
    Venugopal Arumuru
    Harekrishna Yadav
    Transactions of the Indian National Academy of Engineering, 2025, 10 (2) : 307 - 330