LIPSIE DEVICE - PB-17LI IRRADIATION IN WATER LOOP WITH ONLINE TRITIUM MEASUREMENTS

被引:0
作者
THEVENOT, G [1 ]
LEFEVRE, F [1 ]
ESTRADE, J [1 ]
ROCHE, M [1 ]
FLAMENT, T [1 ]
TERLAIN, A [1 ]
机构
[1] CENFAR,SECNAU,SCECF,DTM,CEREM,DTA,F-92260 FONTENAY ROSES,FRANCE
关键词
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Pb-17Li blanket has to be investigated. This has been done in Lipsie irradiation performed by CEA in the OSIRIS reactor. The Isabelle 4 PWR loop, in the OSIRIS reactor pool, has been adapted to allow us to irradiate in demineralized water at 15 MPa and 300-degrees-C a 316L stainless steel capsule of 0.025 m diameter, containing about 0, 450 kg of Pb-17Li manufactured with natural lithium. Two tritium measurements systems have been specially developed around radioactivity scintillation counting devices: one for tritium in cooling water out of the capsule and one for tritium in helium gas after sweeping or sparging in Pb-17Li inside the capsule. This paper describes the loop used for this irradiation and the tritium measurement systems. The experiment will enable us to estimate tritium permeation rate through the capsule wall in Demo-representative conditions of tritium in Pb-17Li and also study the effect of oxidation of the external capsule wall on tritium permeation by oxygen injection near the capsule.
引用
收藏
页码:226 / 230
页数:5
相关论文
共 2 条
[1]   IRRADIATION FACILITIES DEVELOPMENT AT CEA FOR SOLID AND LIQUID BREEDER BLANKETS QUALIFICATION PROGRAMS [J].
ALBERMAN, A ;
LEFEVRE, F ;
THEVENOT, G ;
MASSON, M ;
SAVINEAU, M .
JOURNAL OF NUCLEAR MATERIALS, 1991, 179 :1154-1157
[2]  
1982, M LUCOT EURATOM WORK