SINGLE-SHOT VERSUS INTERLEAVED ECHO-PLANAR MR-IMAGING - APPLICATION TO VISUALIZATION OF CARDIAC-VALVE LEAFLETS

被引:10
|
作者
DAVIS, CP [1 ]
MCKINNON, GC [1 ]
DEBATIN, JF [1 ]
DUEWELL, S [1 ]
VONSCHULTHESS, GK [1 ]
机构
[1] UNIV ZURICH HOSP,DEPT MED RADIOL,CH-8091 ZURICH,SWITZERLAND
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1995年 / 5卷 / 01期
关键词
HEART; VALVES; IMAGE PROCESSING; PULSE SEQUENCES; RAPID IMAGING;
D O I
10.1002/jmri.1880050119
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Visualization of the cardiac valves with standard magnetic resonance (MR) imaging is not adequate because of long acquisition times. Echo-planar imaging (EPI) can, however, be performed with a temporal resolution (30-50 msec) comparable to that of echocardiography. The authors evaluated the feasibility of real-time imaging of cardiac valve motion with ultrafast MR techniques, Eight healthy volunteers and three patients with mitral stenosis and regurgitation were studied with a 1.5-T whole-body imager, Two different EPI sequences were assessed: a standard single-shot gradient-echo EPI (GEPI) sequence and a fast imaging technique based on multiple-shot EPI with interleaved k-space acquisition (IGEPI). Fat-suppressed images with an in-plane resolution of 3.7 x 3.7 mm were obtained equally spaced through the cardiac cycle, Half-k-space acquisition was used, Morphologic evaluation was superior with IGEPI, owing to the better intracavitary signal homogeneity (P<.01), and the mitral valve leaflets were easier to identify on systolic images, IGEPI provided adequate valve visibility in all three patients.
引用
收藏
页码:107 / 112
页数:6
相关论文
共 16 条
  • [1] CARDIAC ECHO-PLANAR MR-IMAGING - COMPARISON OF SINGLE-SHOT AND MULTIPLE-SHOT TECHNIQUES
    WETTER, DR
    MCKINNON, GC
    DEBATIN, JF
    VONSCHULTHESS, GK
    RADIOLOGY, 1995, 194 (03) : 765 - 770
  • [2] ECHO-PLANAR MR-IMAGING
    EDELMAN, RR
    WIELOPOLSKI, P
    SCHMITT, F
    RADIOLOGY, 1994, 192 (03) : 600 - 612
  • [3] NORMAL HEART - EVALUATION WITH ECHO-PLANAR MR-IMAGING
    DAVIS, CP
    MCKINNON, GC
    DEBATIN, JF
    WETTER, D
    EICHENBERGER, AC
    DUEWELL, S
    VONSCHULTHESS, GK
    RADIOLOGY, 1994, 191 (03) : 691 - 696
  • [4] ECHO-PLANAR IMAGING OF THE LIVER WITH A STANDARD MR-IMAGING SYSTEM
    BUTTS, K
    RIEDERER, SJ
    EHMAN, RL
    FELMLEE, JP
    GRIMM, RC
    RADIOLOGY, 1993, 189 (01) : 259 - 264
  • [5] MEASUREMENT OF STROKE VOLUME AND CARDIAC-OUTPUT WITHIN A SINGLE-BREATH HOLD WITH ECHO-PLANAR MR-IMAGING
    HUNTER, GJ
    HAMBERG, LM
    WEISSKOFF, RM
    HALPERN, EF
    BRADY, TJ
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (01): : 51 - 58
  • [6] MR imaging of the liver: Comparison between single-shot echo-planar and half-Fourier rapid acquisition with relaxation enhancement sequences
    Yamashita, Y
    Tang, Y
    Namimoto, T
    Mitsuzaki, K
    Takahashi, M
    RADIOLOGY, 1998, 207 (02) : 331 - 337
  • [7] Diffusion-weighted MR imaging with single-shot echo-planar imaging in the upper abdomen: preliminary clinical experience in 61 patients
    Ichikawa, T
    Haradome, H
    Hachiya, J
    Nitatori, T
    Araki, T
    ABDOMINAL IMAGING, 1999, 24 (05): : 456 - 461
  • [8] MEASUREMENT OF RENAL TRANSIT OF GADOPENTETATE DIMEGLUMINE WITH ECHO-PLANAR MR-IMAGING
    WOLF, GL
    HOOP, B
    CANNILLO, JA
    ROGOWSKA, JA
    HALPERN, EF
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (03): : 365 - 372
  • [9] DYNAMIC GADOLINIUM-ENHANCED ECHO-PLANAR MR-IMAGING OF THE LIVER - EFFECT OF PULSE SEQUENCE AND DOSE ON ENHANCEMENT
    REIMER, P
    SAINI, S
    KWONG, KK
    COHEN, MS
    WEISSLEDER, R
    BRADY, TJ
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (03): : 331 - 335
  • [10] CONTRAST-ENHANCED ECHO-PLANAR MR-IMAGING OF MYOCARDIAL PERFUSION - PRELIMINARY-STUDY IN HUMANS
    EDELMAN, RR
    LI, W
    RADIOLOGY, 1994, 190 (03) : 771 - 777