DETERMINATION OF GLUCOSE-OXIDASE BY MEANS OF THE CHEMILUMINESCENCE OF CYPRIDINA LUCIFERIN ANALOG

被引:5
|
作者
MITANI, M [1 ]
KOINUMA, Y [1 ]
KOSUGI, M [1 ]
机构
[1] GUNMA UNIV,FAC ENGN,DEPT CHEM,KIRYU,GUNMA 376,JAPAN
关键词
LUCIFERIN ANALOG; GLUCOSE OXIDASE; CHEMILUMINESCENCE;
D O I
10.2116/analsci.10.267
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
FeCl2 was found to be a useful catalyst for the determination of H2O2 based on the chemiluminescence of a Cypridina luciferin analogue, 2-methyl-6-phenyl-(p-methoxyphenyl)-3,7-dihydroimidazo[1,2-a]pyrazin-3-one (MCLA). By this method, H2O2 was detected in a range from 300 pmol/ml to 10 nmol/ml. In addition, glucose oxidase (GOD) was determined in a range from 1.18 x 10(-5) units/ml (280 amol/ml) to 7.56 x 10(-4) units/ml (17.9 fmol/ml) when GOD was incubated with glucose for 10 min at 34-degrees-C.
引用
收藏
页码:267 / 269
页数:3
相关论文
共 50 条
  • [31] ERRORS IN THE DETERMINATION OF GLUCOSINOLATE IN RAPESEED USING GLUCOSE-OXIDASE - PEROXIDASE
    MAILER, RJ
    VONARX, MM
    ANALYST, 1989, 114 (11) : 1507 - 1508
  • [32] DETERMINATION OF THE INTRINSIC KINETIC CONSTANTS OF IMMOBILIZED GLUCOSE-OXIDASE AND CATALASE
    TSE, PHS
    LEYPOLDT, JK
    GOUGH, DA
    BIOTECHNOLOGY AND BIOENGINEERING, 1987, 29 (06) : 696 - 704
  • [33] A GLUCOSE-OXIDASE ENZYME ELECTRODE FOR RAPID-DETERMINATION OF PLASMA-GLUCOSE
    ZAHRADNIKOVA, A
    KLIMES, I
    SVABOVA, E
    CERKASOV, J
    PHYSIOLOGIA BOHEMOSLOVACA, 1984, 33 (06): : 573 - 574
  • [34] REVERSIBLY IMMOBILIZED GLUCOSE-OXIDASE IN THE AMPEROMETRIC FLOW-INJECTION DETERMINATION OF GLUCOSE
    DEALWIS, WU
    HILL, BS
    MEIKLEJOHN, BI
    WILSON, GS
    ANALYTICAL CHEMISTRY, 1987, 59 (22) : 2688 - 2691
  • [35] A COMBINATION OF INVERTASE REACTOR AND GLUCOSE-OXIDASE ELECTRODE FOR THE SUCCESSIVE DETERMINATION OF GLUCOSE AND SUCROSE
    SCHELLER, F
    KARSTEN, C
    ANALYTICA CHIMICA ACTA, 1983, 155 (DEC) : 29 - 36
  • [36] GAS-CHROMATOGRAPHIC DETERMINATION OF GLUCOSE IN SERUM WITH GLUCOSE-OXIDASE CATALASE SYSTEM
    KOBAYASHI, K
    KAWAI, S
    JOURNAL OF CHROMATOGRAPHY, 1983, 275 (02): : 394 - 399
  • [37] APPLICATION OF CHEMI-LUMINESCENCE OF CYPRIDINA LUCIFERIN ANALOG TO IMMOBILIZED ENZYME SENSORS
    KOBAYASHI, T
    SAGA, K
    SHIMIZU, S
    GOTO, T
    ENZYME ENGINEERING, 1982, 6 : 423 - 424
  • [38] GLUCOSE-OXIDASE ENZYME ELECTRODE FOR RAPID-DETERMINATION OF PLASMA-GLUCOSE
    KLIMES, I
    ZAHRADNIKOVA, A
    SVABOVA, E
    CERKASOV, J
    DIABETOLOGIA, 1984, 27 (02) : A296 - A296
  • [39] GLUCOSE-OXIDASE - AN IDEAL ENZYME
    WILSON, R
    TURNER, APF
    BIOSENSORS & BIOELECTRONICS, 1992, 7 (03): : 165 - 185
  • [40] GLUCOSE-OXIDASE IMMUNOENZYME TECHNIQUE
    LEWIN, KJ
    SUFFIN, SC
    PORTER, DD
    MUCK, KB
    YOUNG, JC
    LABORATORY INVESTIGATION, 1979, 40 (02) : 269 - 269