COMPARISON OF NUMERICAL ANALYSES WITH A STATIC LOAD TEST OF A CONTINUOUS FLIGHT AUGER PILE

被引:3
作者
Hol'ko, Michal [1 ]
Stacho, Jakub [2 ]
机构
[1] Slovak Univ Technol Bratislava, Fac Civil Engn, Dept Struct Mech, Bratislava, Slovakia
[2] Slovak Univ Technol Bratislava, Dept Geotechn, Fac Civil Engn, Bratislava, Slovakia
关键词
Pile foundations; replacement piles; CFA piles; numerical analysis; pile design; static load test of pile;
D O I
10.2478/sjce-2014-0017
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The article deals with numerical analyses of a Continuous Flight Auger (CFA) pile. The analyses include a comparison of calculated and measured load-settlement curves as well as a comparison of the load distribution over a pile's length. The numerical analyses were executed using two types of software, i.e., Ansys and Plaxis, which are based on FEM calculations. Both types of software are different from each other in the way they create numerical models, model the interface between the pile and soil, and use constitutive material models. The analyses have been prepared in the form of a parametric study, where the method of modelling the interface and the material models of the soil are compared and analysed. Our analyses show that both types of software permit the modelling of pile foundations. The Plaxis software uses advanced material models as well as the modelling of the impact of groundwater or overconsolidation. The load-settlement curve calculated using Plaxis is equal to the results of a static load test with a more than 95 % degree of accuracy. In comparison, the load-settlement curve calculated using Ansys allows for the obtaining of only an approximate estimate, but the software allows for the common modelling of large structure systems together with a foundation system.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 31 条
[1]   Static analysis of soil/pile interaction in layered soil by BEM/BEM coupling [J].
Almelda, Valerio S. ;
de Paiva, Joao B. .
ADVANCES IN ENGINEERING SOFTWARE, 2007, 38 (11-12) :835-845
[2]  
Brown D. A., 2005, PRACTICAL CONSIDERAT, P251, DOI DOI 10.1061/40778(157)1
[3]  
Coyle H. M., 1966, LOAD TRANSFER AXIALL, P1
[4]  
Cummins D., 2007, 18 EUR YOUNG GEOT EN
[5]   Numerical simulation of pile installation [J].
Dijkstra, J. ;
Broere, W. ;
Heeres, O. M. .
COMPUTERS AND GEOTECHNICS, 2011, 38 (05) :612-622
[6]  
Feda J., 1977, INTERACTION PILE GRO
[7]  
Fleming K., 2008, PILING ENG
[8]  
Gavin K. G., 2009, SHAFT CAPACITY CONTI, P780
[9]  
Hrustinec L., 2014, J CIVIL ENG ARCHITEC, V7, P875
[10]  
Husar R., 2008, GROUND INVESTIGATION