IDENTIFICATION AND ANTIMICROBIAL RESISTANCE PATTERNS OF CLINICAL ISOLATES OF CLOSTRIDIUM-CLOSTRIDIOFORME, CLOSTRIDIUM-INNOCUUM AND CLOSTRIDIUM-RAMOSUM COMPARED WITH THOSE OF CLINICAL ISOLATES OF CLOSTRIDIUM-PERFRINGENS

被引:65
作者
ALEXANDER, CJ
CITRON, DM
BRAZIER, JS
GOLDSTEIN, EJC
机构
[1] SANTA MONICA HOSP MED CTR, MED CTR, RM ALDEN RES LAB, SANTA MONICA, CA 90404 USA
[2] UNIV CALIF LOS ANGELES, DEPT MICROBIOL, LOS ANGELES, CA 90024 USA
[3] UNIV CALIF LOS ANGELES, SCH MED, LOS ANGELES, CA 90024 USA
[4] PUBL HLTH LAB SERV, ANAEROBE REFERENCE UNIT, CARDIFF, S GLAM, WALES
关键词
D O I
10.1128/JCM.33.12.3209-3215.1995
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Clostridium ramosum, C. innocuum, and C. clostridioforme are frequently isolated from clinical specimens including blood. Because of Gram stain variability, a lack of spores, and atypical colonial morphology, identification of these species is often difficult. Three anaerobe identification kits were evaluated for their abilities to identify these species. For comparison, 11 strains of C. perfringens were evaluated in parallel. By using profile numbers and codebooks, the correct genus and species were identified, as follows: with the RapID ANA II kit, 100% (20 of 20) of C. ramosum isolates, 24% (5 of 21) of C. innocuum isolates, and 50% (10 of 20) of C. clostridioforme isolates; with the AnIDent kit, 60% (12 of 20) of C. ramosum isolates, 28% (6 of 21) of C. innocuum isolates, and 90% (18 of 20) of C. clostridioforme isolates; with the ATB32A kit, 70% (14 of 20) of C. ramosum isolates, 0% (0 of 21) of C. innocuum isolates, and 40% (8 of 20) of C. clostridioforme isolates. Profile numbers that overlapped several species were obtained as follows: with the RapID ANA II kit, 0% of C. ramosum isolates, 76% of C. innocuum isolates, and 40% of C. clostridioforme isolates; with the AnIDent kit 40% of C. ramosum isolates, 62% of C. innocuum isolates, and 5% of C. clostridioforme isolates; with the ATB32A kit, 15% of C. ramosum isolates, 52% of C. innocuum isolates, and 25% of C. clostridioforme isolates. One strain of C, innocuum was misidentified by the AnIDent kit, and the remainder yielded profile numbers that were not listed in the codebooks. The MICs of 11 antimicrobial agents including penicillin G, metronidazole, clindamycin, cefoxitin, cefotetan, imipenem, meropenem, amoxicillin clavulanate, ampicillin-sulbactam, piperacillin-tazobactam, and vancomycin were determined by the agar dilution method. All C. perfringens strains were susceptible to all antimicrobial agents tested. Various levels of resistance to cefoxitin, cefotetan, and penicillin G were noted with C. ramosum, C. clostridioforme, and C. innocuum. In addition, resistance to clindamycin was noted with C. ramosum (5%) and C. innocuum (10%). Most strains of C. innocuum were only moderately susceptible to vancomycin (MIG at which 90% of strains are inhibited, 4 mu g/ml).
引用
收藏
页码:3209 / 3215
页数:7
相关论文
共 16 条
[1]   ACCURACY AND REPRODUCIBILITY OF A 4-HOUR METHOD FOR ANAEROBE IDENTIFICATION [J].
APPELBAUM, PC ;
KAUFMANN, CS ;
DEPENBUSCH, JW .
JOURNAL OF CLINICAL MICROBIOLOGY, 1985, 21 (06) :894-898
[2]   SURVEY OF ANAEROBIC SUSCEPTIBILITY PATTERNS IN CANADA [J].
BOURGAULT, AM ;
HARDING, GK ;
SMITH, JA ;
HORSMAN, GB ;
MARRIE, TJ ;
LAMOTHE, F .
ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 1986, 30 (05) :798-801
[3]  
BRAZIER J, UNPUB
[4]   COMPARISON OF THE PRAS-II, AN-IDENT, AND RAPID-ANA SYSTEMS FOR IDENTIFICATION OF ANAEROBIC-BACTERIA [J].
BURLAGE, RS ;
ELLNER, PD .
JOURNAL OF CLINICAL MICROBIOLOGY, 1985, 22 (01) :32-35
[5]   CLINICAL-EVALUATION OF THE RAPID-ANA-II PANEL FOR IDENTIFICATION OF ANAEROBIC-BACTERIA [J].
CELIG, DM ;
SCHRECKENBERGER, PC .
JOURNAL OF CLINICAL MICROBIOLOGY, 1991, 29 (03) :457-462
[6]  
Chen J. -S., 1977, ANAEROBE LAB MANUAL, VFourth
[7]   COMPARATIVE SUSCEPTIBILITY OF THE BACTEROIDES-FRAGILIS GROUP SPECIES AND OTHER ANAEROBIC-BACTERIA TO MEROPENEM, IMIPENEM, PIPERACILLIN, CEFOXITIN, AMPICILLIN SULBACTAM, CLINDAMYCIN AND METRONIDAZOLE [J].
GOLDSTEIN, EJC ;
CITRON, DM ;
CHERUBIN, CE ;
HILLIER, SL .
JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 1993, 31 (03) :363-372
[8]   ACCURACY AND REPRODUCIBILITY OF THE 4-HOUR ATB-32A METHOD FOR ANAEROBE IDENTIFICATION [J].
KITCH, TT ;
APPELBAUM, PC .
JOURNAL OF CLINICAL MICROBIOLOGY, 1989, 27 (11) :2509-2513
[9]   EVALUATION OF THE ATB-32-A SYSTEM FOR IDENTIFICATION OF ANAEROBIC-BACTERIA ISOLATED FROM CLINICAL SPECIMENS [J].
LOONEY, WJ ;
GALLUSSER, AJC ;
MODDE, HK .
JOURNAL OF CLINICAL MICROBIOLOGY, 1990, 28 (07) :1519-1524
[10]   EVALUATION OF THE NEW RAPID-ANA-II SYSTEM FOR THE IDENTIFICATION OF CLINICAL ANAEROBIC ISOLATES [J].
MARLER, LM ;
SIDERS, JA ;
WOLTERS, LC ;
PETTIGREW, Y ;
SKITT, BL ;
ALLEN, SD .
JOURNAL OF CLINICAL MICROBIOLOGY, 1991, 29 (05) :874-878