COMPARISON OF HEMODYNAMIC RESPONSE TO TRACHEAL INTUBATION WITH MACINTOSH AND MCCOY LARYNGOSCOPES

被引:1
作者
Jitendra, Mukta [1 ]
Sharma, Sonal [1 ]
Katoch, Madan [1 ]
Gulati, Smriti [1 ]
Gupta, Heena [1 ]
机构
[1] GMC, Dept Anaesthesia, Jammu, India
来源
JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS | 2015年 / 4卷 / 50期
关键词
Tracheal intubation; Macintosh; McCoy; Hemodynamic;
D O I
10.14260/jemds/2015/1255
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: McCoy laryngoscope incorporates a modification of the Macintosh laryngoscope. It was designed to facilitate difficult intubation. Use of this blade reduces the lifting force required during laryngoscopy. MATERIAL AND METHODS: The present prospective randomized study was conducted to evaluate the effectiveness of McCoy laryngoscope in attenuating the pressor response secondary to tracheal intubation as compared to Macintosh laryngoscope in terms of magnitude and duration in 80 patients of ASA Grade I and II. The changes in heart rate, systolic, diastolic, mean arterial pressure and rate pressure product were observed for 10 minutes post intubation. Time taken for laryngoscopy and intubation was also noted. RESULTS: Following laryngoscopy and intubation, it was observed that there was statistically significant rise in heart rate, systolic blood pressure, diastolic blood pressure, mean arterial pressure and rate pressure product in both the groups. The increase in hemodynamic variables was statistically significant with Macintosh laryngoscope as compared to McCoy laryngoscope and lasted for lesser duration in McCoy group. CONCLUSION: McCoy laryngoscope produces significantly less marked hemodynamic response as compared to Macintosh laryngoscope.
引用
收藏
页码:8676 / 8684
页数:9
相关论文
共 14 条
[1]  
Bhosle P, 2013, INTERNET J ANAESTHES, V32, P1
[2]  
길양숙, 2005, Korean Journal of Anesthesiology, V49, P147
[3]   ACUTE HYPERTENSION DURING INDUCTION OF ANAESTHESIA AND ENDOTRACHEAL INTUBATION IN NORMOTENSIVE MAN [J].
FORBES, AM ;
DALLY, FG .
BRITISH JOURNAL OF ANAESTHESIA, 1970, 42 (07) :618-+
[4]   RATE-PRESSURE PRODUCT AS AN INDEX OF MYOCARDIAL OXYGEN-CONSUMPTION DURING EXERCISE IN PATIENTS WITH ANGINA-PECTORIS [J].
GOBEL, FL ;
NORDSTROM, LA ;
NELSON, RR ;
JORGENSEN, CR ;
WANG, Y .
CIRCULATION, 1978, 57 (03) :549-556
[5]  
Haidry Mehtab A, 2013, J Anaesthesiol Clin Pharmacol, V29, P196, DOI 10.4103/0970-9185.111710
[6]  
Macintosh RR., 1943, LANCET, V241, P205, DOI 10.1016/S0140-6736(00)89390-3
[7]   A comparison of the forces exerted during laryngoscopy - The Macintosh versus the McCoy blade [J].
McCoy, EP ;
Mirakhur, RK ;
Rafferty, C ;
Bunting, H ;
Austin, BA .
ANAESTHESIA, 1996, 51 (10) :912-915
[8]   THE LEVERING LARYNGOSCOPE [J].
MCCOY, EP ;
MIRAKHUR, RK .
ANAESTHESIA, 1993, 48 (06) :516-519
[9]   A COMPARISON OF THE STRESS-RESPONSE TO LARYNGOSCOPY - THE MACINTOSH VERSUS THE MCCOY BLADE [J].
MCCOY, EP ;
MIRAKHUR, RK ;
MCCLOSKEY, BV .
ANAESTHESIA, 1995, 50 (11) :943-946
[10]  
Nishiyama T, 1997, Masui, V46, P1519