THE USE OF A RADIOCHROMIC DETECTOR FOR THE DETERMINATION OF STEREOTAXIC RADIOSURGERY DOSE CHARACTERISTICS

被引:96
作者
MCLAUGHLIN, WL
SOARES, CG
SAYEG, JA
MCCULLOUGH, EC
KLINE, RW
WU, A
MAITZ, AH
机构
[1] UNIV KENTUCKY,DEPT RADIAT MED,LEXINGTON,KY 40536
[2] UNIV KENTUCKY,DEPT CLIN SCI,LEXINGTON,KY 40536
[3] MAYO CLIN & MAYO FDN,DEPT RADIAT ONCOL,ROCHESTER,MN 55905
[4] UNIV PITTSBURGH,CTR JOINT RADIAT ONCOL,DEPT RADIAT ONCOL,PITTSBURGH,PA 15213
关键词
ABSORBED DOSE DISTRIBUTIONS; DOSIMETRY; GAMMA-RADIATION; RADIOCHROMIC FILMS; STEREOTAXIC RADIOSURGERY;
D O I
10.1118/1.597384
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The measurement of absorbed dose as well as dose distributions (profiles and isodose curves) for small radiation fields (as encountered in stereotactic surgery) has been difficult due to the usual large detector size or densitometer aperture ( > 1 mm) relative to the radiation field (as small as (4 mm). The radiochromic direct-imaging film, when read with a scanning laser microdensitometer laser beam diameter 0.1 mm), overcomes this difficulty and has advantages over conventional film in providing improved precision, better tissue equivalence, greater dynamic range, higher spatial resolution, and room light handling. As a demonstration of suitability, the calibrated radiochromic film has been used to measure the dose characteristics for the 18-, 14-, 8-, and 4-mm fields from the gamma-ray stereotactic surgery units at Mayo Clinic and the University of Pittsburgh. Intercomparisons of radiochromic film with conventional methods of dosimetry and vendor-supplied computational dose planning system values indicate agreement to within +/- 2%. The dose, dose profiles, and isodose curves obtained with radiochromic film can provide high-spatial-resolution information of value for acceptance testing and quality control of dose measurement and/or calculation.
引用
收藏
页码:379 / 388
页数:10
相关论文
共 29 条
[1]  
BERGER M, 1992, NISTIR4999 NAT I STA
[2]  
COLUMBO F, 1985, APPL NEUROPHYSIOL, V48, P133
[3]   ANALYSIS OF PHYSICAL PARAMETERS ASSOCIATED WITH THE MEASUREMENT OF HIGH-ENERGY X-RAY PENUMBRA [J].
DAWSON, DJ ;
HARPER, JM ;
AKINRADEWO, AC .
MEDICAL PHYSICS, 1984, 11 (04) :491-497
[4]   A POLYSTYRENE ABSORBED-DOSE-RATE CALORIMETER [J].
DOMEN, SR ;
BA, WZ .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1987, 24-5 :1054-1057
[5]   MEASUREMENT OF ABSORBED DOSES NEAR METAL AND DENTAL MATERIAL INTERFACES IRRADIATED BY X-RAY AND GAMMA-RAY THERAPY BEAMS [J].
FARAHANI, M ;
EICHMILLER, FC ;
MCLAUGHLIN, WL .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (03) :369-385
[6]   METAL POLYSILOXANE SHIELDS FOR RADIATION-THERAPY OF MAXILLOFACIAL TUMORS [J].
FARAHANI, M ;
EICHMILLER, FC ;
MCLAUGHLIN, WL .
MEDICAL PHYSICS, 1991, 18 (02) :273-278
[7]  
Hayzer W. G., 1992, PHOTOELECTRON IMAGIN, V2, P8
[8]  
HUMPHREYS JC, 1988, NBS25011 NAT I STAND
[9]  
LARSSON B, 1963, ACTA CHIR SCAND, V125, P1
[10]  
Leksell L, 1955, KUNGL FYSIOGRAF SALL, V25, P1