MR LYMPHOGRAPHY WITH A LYMPHOTROPIC T-1-TYPE MR CONTRAST AGENT - GD-DTPA-PGM

被引:58
作者
HARIKA, L
WEISSLEDER, R
POSS, K
ZIMMER, C
PAPISOV, MI
BRADY, TJ
机构
[1] MASSACHUSETTS GEN HOSP,CTR NMR,DEPT RADIOL,MR PHARMACEUT PROGRAM,BOSTON,MA 02114
[2] HARVARD UNIV,SCH MED,BOSTON,MA
关键词
MRI; CONTRAST AGENT; POLYMER; MACROMOLECULE;
D O I
10.1002/mrm.1910330113
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A model system of a paramagnetic lymphotropic MR contrast agent (Gd-DTPA labeled polyglucose associated macrocomplex, PGM) for T-1-weighted MR imaging of lymph nodes in rats and rabbits was evaluated, Pharmacokinetic (tissue accumulation) and MR imaging data (optimal dose and timing parameters) were obtained in normal rats (n = 88) after subcutaneous (SC) injection of paramagnetic, radiolabeled [111In]Gd-DTPA-PGM. A rabbit model of lymph node metastases (n = 8) was ultimately used to demonstrate the potential of MR imaging with Gd-DTPA-PGM for nodal tumor detection, Maximum concentrations of Gd-DTPA-PGM were found in popliteal and paraaortic lymph nodes within 24 h after SC administration, and highest lymph node SNR values were obtained by MR imaging at this time point. The optimum imaging dose was 6-12 mu mol Gd/kg. Tumor-lymph node contrast increased from 0.0 +/- 1.2 precontrast to 19.2 +/- 6.5 (spoiled gradient echo sequence, TR 50/TE 7/flip angle 60 degrees) postcontrast and conspicuity of nodal metastases was improved, Gd-DTPA-PGM accumulates in lymph nodes after SC administration and significantly enhances lymph node signal intensity of normal animals but not metastatic lymph nodes.
引用
收藏
页码:88 / 92
页数:5
相关论文
共 10 条
[1]   CHARACTERIZATION OF LYMPHADENOPATHY BY MAGNETIC-RESONANCE RELAXATION-TIMES - PRELIMINARY-RESULTS [J].
DOOMS, GC ;
HRICAK, H ;
MOSELEY, ME ;
BOTTLES, K ;
FISHER, M ;
HIGGINS, CB .
RADIOLOGY, 1985, 155 (03) :691-697
[2]   DETECTION OF PULMONARY EMBOLI BY USING MR-ANGIOGRAPHY WITH MPEG-PL-GDDTPA - AN EXPERIMENTAL-STUDY IN RABBITS [J].
FRANK, H ;
WEISSLEDER, R ;
BOGDANOV, AA ;
BRADY, TJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (05) :1041-1046
[3]  
LIUNGSTROM KG, 1993, ANN FR ANESTH, V12, P219
[4]  
PAPISOV MI, 1994, 1ST P SMR ANN M SAN, P388
[5]  
PAPISOV MI, 1993, 1993 SOC MAGN RES ME, P499
[6]   MION-ASF - BIOKINETICS OF AN MR RECEPTOR AGENT [J].
SCHAFFER, BK ;
LINKER, C ;
PAPISOV, M ;
TSAI, E ;
NOSSIFF, N ;
SHIBATA, T ;
BOGDANOV, A ;
BRADY, TJ ;
WEISSLEDER, R .
MAGNETIC RESONANCE IMAGING, 1993, 11 (03) :411-417
[7]   CHARACTERISTICS OF GADOLINIUM-DTPA COMPLEX - A POTENTIAL NMR CONTRAST AGENT [J].
WEINMANN, HJ ;
BRASCH, RC ;
PRESS, WR ;
WESBEY, GE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 142 (03) :619-624
[8]   MR LYMPHOGRAPHY - STUDY OF A HIGH-EFFICIENCY LYMPHOTROPHIC AGENT [J].
WEISSLEDER, R ;
HEAUTOT, JF ;
SCHAFFER, BK ;
NOSSIFF, N ;
PAPISOV, MI ;
BOGDANOV, A ;
BRADY, TJ .
RADIOLOGY, 1994, 191 (01) :225-230
[9]  
WEISSLEDER R, 1989, RADIOLOGY, V17, P835
[10]  
WIENER JI, 1986, RADIOLOGY, V160, P299, DOI 10.1148/radiology.160.2.3726104