APPLICATION OF AUTOREGRESSIVE SPECTRAL-ANALYSIS FOR ULTRASOUND ATTENUATION ESTIMATION - INTEREST IN HIGHLY ATTENUATING MEDIUM

被引:52
作者
BALDEWECK, T [1 ]
LAUGIER, P [1 ]
HERMENT, A [1 ]
BERGER, G [1 ]
机构
[1] INSERM, U256, PARIS, FRANCE
关键词
D O I
10.1109/58.368307
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This paper deals with the application of parametric spectral analysis for attenuation estimation on the reflected ultrasound signal of biological tissues. A second-order autoregressive (AR2) model, whose parameters are estimated with the Burg algorithm, is used to estimate the center frequency on echo signals and its evolution versus depth. Data simulation of independent A-lines backscattered by a homogeneous medium of scatterers are generated by a computer model with attenuation values ranging from 1 to 5 dB/cmMHz, an ultrasonic frequency of 5 MHz and different pulse durations. The performance of the estimator is evaluated for time windows ranging from 5 to 0.3 mu s. The comparison is made with the classical Short Time Fourier Analysis using a Fast Fourier Transform (FFT). It is found that the AR2 model provides a better estimation of attenuation than the Fourier technique: the relative error of attenuation is below 5% for windows between 0.6 to 2.5 mu s, while the one obtained with the Fourier technique lies between 3 and 16% for the same window sizes. However, the variance of attenuation estimate is the same with the two techniques. These results offer promises for determining attenuation in highly attenuating medium (material or biological tissue) either because of their structure or because high frequencies are used.
引用
收藏
页码:99 / 110
页数:12
相关论文
共 29 条
[1]   GLOBAL BREAST ATTENUATION - CONTROL-GROUP AND BENIGN BREAST DISEASES [J].
BERGER, G ;
LAUGIER, P ;
THALABARD, JC ;
PERRIN, J .
ULTRASONIC IMAGING, 1990, 12 (01) :47-57
[2]   OPTIMAL PRECISION IN ULTRASOUND ATTENUATION ESTIMATION AND APPLICATION TO THE DETECTION OF DUCHENNE MUSCULAR-DYSTROPHY CARRIERS [J].
BERGER, G ;
LAUGIER, P ;
FINK, M ;
PERRIN, J .
ULTRASONIC IMAGING, 1987, 9 (01) :1-17
[3]  
BURG JP, 1975, THESIS STANFORD U ST
[4]   MODERN SPECTRAL-ANALYSIS TECHNIQUES FOR BLOOD-FLOW VELOCITY AND SPECTRAL MEASUREMENTS WITH PULSED DOPPLER ULTRASOUND [J].
DAVID, JY ;
JONES, SA ;
GIDDENS, DP .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (06) :589-596
[5]   ULTRASONIC SIGNAL-PROCESSING FOR INVIVO ATTENUATION MEASUREMENT - SHORT-TIME FOURIER-ANALYSIS [J].
FINK, M ;
HOTTIER, F ;
CARDOSO, JF .
ULTRASONIC IMAGING, 1983, 5 (02) :117-135
[6]   DIFFRACTION EFFECTS IN PULSE-ECHO MEASUREMENT [J].
FINK, MA ;
CARDOSO, JF .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1984, 31 (04) :313-329
[7]   SPECTRAL CHARACTERIZATION AND ATTENUATION MEASUREMENTS IN ULTRASOUND [J].
FLAX, SW ;
PELC, NJ ;
GLOVER, GH ;
GUTMANN, FD ;
MCLACHLAN, M .
ULTRASONIC IMAGING, 1983, 5 (02) :95-116
[8]   ULTRASONIC ASSESSMENT OF SKIN AND SURGICAL WOUNDS UTILIZING BACKSCATTER ACOUSTIC TECHNIQUES TO ESTIMATE ATTENUATION [J].
FORSTER, FK ;
OLERUD, JE ;
RIEDERERHENDERSON, MA ;
HOLMES, AW .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (01) :43-53
[9]   ATTENUATION ESTIMATION ON PHANTOMS - A STABILITY TEST [J].
HE, P ;
GREENLEAF, JF .
ULTRASONIC IMAGING, 1986, 8 (01) :1-10
[10]   ULTRASOUND ATTENUATION ESTIMATION IN SOFT-TISSUE USING THE ENTROPY DIFFERENCE OF PULSED ECHOES BETWEEN 2 ADJACENT ENVELOPE SEGMENTS [J].
JANG, HS ;
SONG, TK ;
PARK, SB .
ULTRASONIC IMAGING, 1988, 10 (04) :248-264