Instrumented flow-following sensor particles with magnetic position detection and buoyancy control

被引:14
作者
Reinecke, Sebastian Felix [1 ]
Hampel, Uwe [1 ,2 ]
机构
[1] HZDR, D-01328 Dresden, Germany
[2] Tech Univ Dresden, AREVA Endowed Chair Imaging Tech Energy & Proc E, D-01062 Dresden, Germany
关键词
D O I
10.5194/jsss-5-213-2016
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A concept for buoyancy control and magnetic position detection has been developed for the improvement of instrumented flow-following sensor particles. The sensor particles are used for investigation of hydrodynamic and biochemical processes in large-scale vessels such as biogas fermenters, bioreactors and aerated sludge basins. Neutral buoyancy of the sensor particles is required for tracing of the fluid flows. Buoyancy control is performed by adjustment of the sensor particles' volume, which is altered by an integrated piston. A miniaturized linear actuator, namely a stepper motor with linear transmission, is operated by a microcontroller to drive the piston. The buoyancy control unit enables accurate automated taring of the sensor particles in the stagnant process fluid to achieve neutral buoyancy. Therefore, the measured vertical position of the sensor particle as a function of the hydrostatic pressure is used as feedback. It has an incremental density change of 0.0136% as compared to water and a residual drift velocity of approximately 3.6 x 10 3 m s(-1). Furthermore, a minimum density of 926 kg m(-3) can be set by full extension of the piston, which allows floating of the sensor particles after a defined event, namely critical charge of battery, full data storage or the end of a fixed time cycle. Thus, recovery of the sensor particles can proceed easily from the fluid level. The sensor particles with a buoyancy control unit are tested for depths up to 15 m. Also, detection of a local magnetic position marker by the sensor particles has been implemented to enhance movement tracking. It was tested in a lab-scale biogas digester and was used for estimation of the liquid circulation time distribution and Peclet number to describe the macro-flow.
引用
收藏
页码:213 / 220
页数:8
相关论文
共 10 条
  • [1] [Anonymous], 2003, HDB MECH VERFAHRENST
  • [2] Wireless Sensor Networks for Industrial Processes
    Antoniou, M.
    Boon, M. C.
    Green, P. N.
    Green, P. R.
    York, T. A.
    [J]. SAS 2009 - IEEE SENSORS APPLICATIONS SYMPOSIUM, PROCEEDINGS, 2009, : 13 - 18
  • [3] Bryant J., 1969, THESIS U CAMBRIDGE
  • [4] Day A., 1975, THESIS
  • [5] DRAG COEFFICIENT AND TERMINAL VELOCITY OF SPHERICAL AND NONSPHERICAL PARTICLES
    HAIDER, A
    LEVENSPIEL, O
    [J]. POWDER TECHNOLOGY, 1989, 58 (01) : 63 - 70
  • [6] Liepe F., 1998, RUHRWERKE THEORETISC
  • [7] Macro-mixing in a draft-tube airlift bioreactor
    Luo, Hu-Ping
    Al-Dahhan, Muthanna H.
    [J]. CHEMICAL ENGINEERING SCIENCE, 2008, 63 (06) : 1572 - 1585
  • [8] Flow following sensor particles-Validation and macro-mixing analysis in a stirred fermentation vessel with a highly viscous substrate
    Reinecke, S.
    Deutschmann, A.
    Jobst, K.
    Kryk, H.
    Friedrich, E.
    Hampel, U.
    [J]. BIOCHEMICAL ENGINEERING JOURNAL, 2012, 69 : 159 - 171
  • [9] REINECKE S. F, 2014, THESIS, V52
  • [10] Autonomous sensor particle for parameter tracking in large vessels
    Thiele, Sebastian
    Da Silva, Marco Jose
    Hampel, Uwe
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2010, 21 (08)