STATUS OF SEMIINSULATING CADMIUM TELLURIDE FOR NUCLEAR RADIATION DETECTORS

被引:81
|
作者
HAGEALI, M
SIFFERT, P
机构
[1] Centre de Recherches Nucléaires (IN2P3), Laboratoire PHASE (UPR du CNRS n 292), 67037 Strasbourg Cedex 2
关键词
D O I
10.1016/0168-9002(92)91191-B
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A brief review of our earlier self-consistent model of pure and halogen compensated semi-insultating CdTe material is presented. We provide a new reading of this model, in view of recent results, concerning (Cl), (Cu), and (H) introduced in CdTe in order to understand the variation of founded levels and to improve our view of these problems. The defect levels behaviour must be seen in terms of general thermodynamic equilibrium between different charge states of structural defects, impurities and their complexes.
引用
收藏
页码:313 / 323
页数:11
相关论文
共 50 条
  • [41] Surface passivation of cadmium zinc telluride radiation detectors by potassium hydroxide solution
    Chattopadhyay, K
    Hayes, M
    Ndap, JO
    Burger, A
    Lu, WJ
    McWhinney, HG
    Grady, T
    James, RB
    JOURNAL OF ELECTRONIC MATERIALS, 2000, 29 (06) : 708 - 712
  • [42] Cadmium zinc telluride and its use as a nuclear radiation detector material
    Schlesinger, TE
    Toney, JE
    Yoon, H
    Lee, EY
    Brunett, BA
    Franks, L
    James, RB
    MATERIALS SCIENCE & ENGINEERING R-REPORTS, 2001, 32 (4-5): : 103 - 189
  • [43] Investigation of the electronic properties of cadmium zinc telluride (CZT) detectors using a nuclear microprobe
    Vizkelethy, G
    Brunett, BA
    Walsh, DS
    James, RB
    Doyle, BL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2): : 563 - 567
  • [44] Current status and issues in the surface passivation technology of mercury cadmium telluride infrared detectors
    Agnihotri, OP
    Musca, CA
    Faraone, L
    SEMICONDUCTOR SCIENCE AND TECHNOLOGY, 1998, 13 (08) : 839 - 845
  • [45] Thickness Scalability of Large Volume Cadmium Zinc Telluride High Resolution Radiation Detectors
    Awadalla, S. A.
    Chen, H.
    Mackenzie, J.
    Lu, P.
    Iniewski, K.
    Marthandam, P.
    Redden, R.
    Bindley, G.
    He, Z.
    Zhang, F.
    Groza, M.
    Burger, A.
    Mayo, D. R.
    Sullivan, C. L.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4870 - +
  • [46] HIGH-EFFICIENCY CADMIUM TELLURIDE DETECTORS OF X- AND gamma-RADIATION
    Maslyanchuk, O. L.
    Aoki, T.
    Sklyarchuk, V. M.
    Melnychuk, S. V.
    Kosyachenko, L. A.
    Grushko, E. V.
    UKRAINIAN JOURNAL OF PHYSICS, 2014, 59 (01): : 17 - 33
  • [47] Effects of proton-induced radiation damage on cadmium zinc telluride pixel detectors
    Wong, AS
    Harrison, FA
    Varnell, LS
    GAMMA-RAY AND COSMIC-RAY DETECTORS, TECHNIQUES, AND MISSIONS, 1996, 2806 : 442 - 448
  • [48] Thickness scalability of large volume cadmium zinc telluride high resolution radiation detectors
    Awadalla, S. A.
    Chen, H.
    Mackenzie, J.
    Lu, P.
    Iniewski, K.
    Marthandam, P.
    Redden, R.
    Bindley, G.
    He, Z.
    Zhang, F.
    JOURNAL OF APPLIED PHYSICS, 2009, 105 (11)
  • [49] CADMIUM TELLURIDE X-RAY DETECTORS
    MASLOVA, LV
    MATVEEV, OA
    RYVKIN, SM
    TERENTEV, AI
    KHUSAINOV, AK
    REVUE DE PHYSIQUE APPLIQUEE, 1977, 12 (02): : 291 - 292
  • [50] Collimation of portable cadmium telluride detectors for biotelemetry
    Bojsen, J.
    Staberg, B.
    Kolendorf, K.
    International Journal of Applied Radiation and Isotopes, 1982, 33 (12): : 1359 - 1363