REVERSED-PHASE CHROMATOGRAPHY OF PROTEINS AND PEPTIDES ON COMPRESSED CONTINUOUS BEDS

被引:55
作者
HJERTEN, S [1 ]
NAKAZATO, K [1 ]
MOHAMMAD, J [1 ]
EAKER, D [1 ]
机构
[1] KIATASO UNIV,SCH HYG SCI,SAGAMIHARA,KANAGAWA 228,JAPAN
关键词
COLUMN LIQUID CHROMATOGRAPHY; REVERSED-PHASE CHROMATOGRAPHY; CONTINUOUS BEDS; POLYMER PHASES; PEPTIDES; PROTEINS;
D O I
10.1007/BF02278636
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The polymer beds described are synthesized in aqueous solution directly in the column or batchwise in the form of large clusters of small particles. The conventional, expensive step involving prepreparation of beads in an organic solvent is thus omitted. Beds were synthesized from piperazine diacrylamide, methacrylamide and allyl glycidyl ether. The epoxy-activated beds thus obtained were used for covalent attachment of either nonpolar ligands (e.g. octadecanol) or polar OH-rich substances (e.g. dextran). The non-polar beds were used for reversed-phase chromatography, as were polar ones following coupling with 1,2-epoxyoctadecane. Coating with OH-rich substances serves two purposes: (1) the matrix becomes hydrophilic, decreasing nonspecific interactions (modifiers can be excluded) and hence increases resolution and (II) many - OH groups are available (e.g. for coupling to epoxides), a prerequisite for high ligand density. Resolution of proteins was high even at high flow rates. Depending on the method used for the synthesis of the bed, resolution of proteins either increased with an increase in flow rate or decreased slightly. Choice of the correct temperature was very important for high resolution of CNBr-digested peptides.
引用
收藏
页码:287 / 294
页数:8
相关论文
共 16 条
[1]   DIFFERENT TYPES OF PACKED COLUMNS IN LIQUID-SOLID CHROMATOGRAPHY [J].
HALASZ, I ;
WALKLING, P .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1969, 7 (03) :129-&
[2]   THE DESIGN OF AGAROSE BEDS FOR HIGH-PERFORMANCE HYDROPHOBIC-INTERACTION CHROMATOGRAPHY AND ION-EXCHANGE CHROMATOGRAPHY WHICH SHOW INCREASING RESOLUTION WITH INCREASING FLOW-RATE [J].
HJERTEN, S ;
YAO, KQ ;
LIAO, JL .
MAKROMOLEKULARE CHEMIE-MACROMOLECULAR SYMPOSIA, 1988, 17 :349-357
[3]   CONTINUOUS BEDS - HIGH-RESOLVING, COST-EFFECTIVE CHROMATOGRAPHIC MATRICES [J].
HJERTEN, S ;
LI, YM ;
LIAO, JL ;
MOHAMMAD, J ;
NAKAZATO, K ;
PETTERSSON, G .
NATURE, 1992, 356 (6372) :810-811
[4]  
HJERTEN S, 1962, ARCH BIOCHEM BIOPHYS, P147
[5]  
HJERTEN S, 1992, BIOTECHNOL APPL BIOC, V15, P247
[6]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ON CONTINUOUS POLYMER BEDS [J].
HJERTEN, S ;
LIAO, JL ;
ZHANG, R .
JOURNAL OF CHROMATOGRAPHY, 1989, 473 (01) :273-275
[7]   SOME STUDIES ON THE RESOLVING POWER OF AGAROSE-BASED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC MEDIA FOR THE SEPARATION OF MACROMOLECULES [J].
HJERTEN, S ;
LIU, ZQ ;
YANG, D .
JOURNAL OF CHROMATOGRAPHY, 1984, 296 (JUL) :115-120
[8]  
HJERTEN S, 1968, METHODS IMMUNOLOGY I, V2, P142
[9]  
HJERTEN S, 1993, IN PRESS J CHROMATOG
[10]   EVIDENCE FOR TURBULENCE AND COUPLING IN CHROMATOGRAPHIC COLUMNS [J].
KNOX, JH .
ANALYTICAL CHEMISTRY, 1966, 38 (02) :253-&