Accuracy of Implant Placement Utilizing Customized Patient Instrumentation in Total Knee Arthroplasty

被引:18
作者
Bugbee, William D. [1 ]
Mizu-uchi, Hideki [2 ]
Patil, Shantanu [2 ]
D'Lima, Darryl [2 ]
机构
[1] Scripps Clin, Div Orthopaed Surg, 10666 North Torrey Pines Rd,MS116, La Jolla, CA 92037 USA
[2] Scripps Clin, Shiley Ctr Orthopaed Res & Educ, La Jolla, CA 92037 USA
关键词
D O I
10.1155/2013/891210
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Customized patient instrumentation (CPI) combines preoperative planning with customized cutting jigs to position and align implants during total knee arthroplasty (TKA). We compared postoperative implant alignment of patients undergoing surgery with CPI to traditional TKA instrumentation for accuracy of implant placement. Twenty-five consecutive TKAs using CPI were analyzed. Preoperative CT scans of the lower extremities were segmented using a computer program. Limb alignment and mechanical axis were computed. Virtual implantation of computer-aided design models was done. Postoperative coronal and sagittal view radiographs were obtained. Using 3D image-matching software, relative positions of femoral and tibial implants were determined. Twenty-five TKAs implanted using traditional instrumentation were also analyzed. For CPI, difference in alignment from the preoperative plan was calculated. In the CPI group, the mean absolute difference between the planned and actual femoral placements was 0.67 degrees in the coronal plane and 1.2 degrees in the sagittal plane. For tibial alignment, the mean absolute difference was 0.9 degrees in the coronal plane and 1.3 degrees in the sagittal plane. For traditional instrumentation, difference from ideal placement for the femur was 1.5 degrees in the coronal plane and 2.3 degrees in the sagittal plane. For the tibia, the difference was 1.8 degrees in the coronal plane. CPI achieved accurate implant positioning and was superior to traditional TKA instrumentation.
引用
收藏
页数:6
相关论文
共 15 条
[1]   Tibial component failure mechanisms in total knee arthroplasty [J].
Berend, ME ;
Ritter, MA ;
Meding, JB ;
Faris, PM ;
Keating, EM ;
Redelman, R ;
Faris, GW ;
Davis, KE .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (428) :26-34
[2]   Computer-Assisted Techniques Versus Conventional Guides for Component Alignment in Total Knee Arthroplasty [J].
Blakeney, William G. ;
Khan, Riaz J. K. ;
Wall, Simon J. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (15) :1377-1384
[3]  
CATES HE, 1993, CLIN ORTHOP RELAT R, P32
[4]   Consistency of implantation of a total knee arthroplasty with a non-image-based navigation system - A case-control study of 235 cases compared with 235 conventionally implanted prostheses [J].
Jenny, JY ;
Clemens, U ;
Kohler, S ;
Kiefer, H ;
Konermann, W ;
Miehlke, RK .
JOURNAL OF ARTHROPLASTY, 2005, 20 (07) :832-839
[5]   A prospective, randomized study of computer-assisted and conventional total knee arthroplasty - Three-dimensional evaluation of implant alignment and rotation [J].
Matziolis, Georg ;
Krocker, Doerte ;
Weiss, Ulrike ;
Tohtz, Stephan ;
Perka, Carsten .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (02) :236-243
[6]   The evaluation of post-operative alignment in total knee replacement using a CT-based navigation system [J].
Mizu-uchi, H. ;
Matsuda, S. ;
Miura, H. ;
Okazaki, K. ;
Akasaki, Y. ;
Iwamoto, Y. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (08) :1025-1031
[7]   The effect of ankle rotation on cutting of the tibia in total knee arthroplasty [J].
Mizu-Uchi, Hideki ;
Matsuda, Shuichi ;
Miura, Hiromasa ;
Higaki, Hidehiko ;
Okazaki, Ken ;
Iwamoto, Yukihide .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (12) :2632-2636
[8]   Effect of Total Knee Arthroplasty Implant Position on Flexion Angle Before Implant-Bone Impingement [J].
Mizu-uchi, Hideki ;
Colwell, Clifford W., Jr. ;
Matsuda, Shuichi ;
Flores-Hernandez, Cesar ;
Iwamoto, Yukihide ;
D'Lima, Darryl D. .
JOURNAL OF ARTHROPLASTY, 2011, 26 (05) :721-727
[9]   Improved Accuracy of Alignment With Patient-specific Positioning Guides Compared With Manual Instrumentation in TKA [J].
Ng, Vincent Y. ;
DeClaire, Jeffrey H. ;
Berend, Keith R. ;
Gulick, Bethany C. ;
Lombardi, Adolph V., Jr. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (01) :99-107
[10]   Do Patient-specific Guides Improve Coronal Alignment in Total Knee Arthroplasty? [J].
Nunley, Ryan M. ;
Ellison, Bradley S. ;
Zhu, Jinjun ;
Ruh, Erin L. ;
Howell, Stephen M. ;
Barrack, Robert L. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (03) :895-902