Computational efficient method for ECG signal compression based on modified SPIHT technique

被引:9
作者
Kumar, Ranjeet [1 ]
Kumar, A. [1 ]
Akhil, G. [1 ]
Singh, A. [1 ]
Jafri, S. N. H. [1 ]
机构
[1] Design & Mfg Jabalpur, PDPM Indian Inst Informat Technol, Jabalpur 482005, Madhya Pradesh, India
关键词
ECG compression; SPIHT; DCT; discrete cosine transform; DWT; discrete wavelet transform; modified SPIHT; compression ratio;
D O I
10.1504/IJBET.2014.062746
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this paper, an improved method for electrocardiogram (ECG) signal compression using Set Partitioning in Hierarchical Trees (SPIHT) algorithm is proposed. ECG signals are compressed based on different transform such as discrete cosine transform and discrete wavelet transform with modified SPIHT. The modified SPIHT algorithm yields good compression with controlled quantity of signal degradation and requires computational time as compared to earlier published SPIHT algorithms. The proposed algorithm is suitable for the ECG signal compression for telemedicine or e-health system due to minimum computational time.
引用
收藏
页码:173 / 188
页数:16
相关论文
共 39 条
[1]   A novel compression algorithm for electrocardiogram signals based on the linear prediction of the wavelet coefficients [J].
Al-Shrouf, A ;
Abo-Zahhad, M ;
Ahmed, SM .
DIGITAL SIGNAL PROCESSING, 2003, 13 (04) :604-622
[2]   On the use of 2-D coding techniques for ECG signals [J].
Alexandre, Enrique ;
Pena, Antonio ;
Sobreira, Manuel .
IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2006, 10 (04) :809-811
[3]   ECG DATA-COMPRESSION BY SUBBAND CODING [J].
AYDIN, MC ;
CETIN, AE ;
KOYMEN, H .
ELECTRONICS LETTERS, 1991, 27 (04) :359-360
[5]   A low computational complexity algorithm for ECG signal compression [J].
Blanco-Velasco, M ;
Cruz-Roldán, F ;
López-Ferreras, F ;
Bravo-Santos, A ;
Martínez-Muñoz, D .
MEDICAL ENGINEERING & PHYSICS, 2004, 26 (07) :553-568
[6]   MULTICHANNEL ECG DATA-COMPRESSION BY MULTIRATE SIGNAL-PROCESSING AND TRANSFORM DOMAIN CODING TECHNIQUES [J].
CETIN, AE ;
KOYMEN, H ;
AYDIN, MC .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1993, 40 (05) :495-499
[7]  
Chatterjee HK, 2013, INT J BIOMED ENG TEC, V12, P130
[8]  
Ciocoiu I. B., 2009, INT J ADV SCI TECHNO, V13, P15
[9]   COMPRESSION OF THE AMBULATORY ECG BY AVERAGE BEAT SUBTRACTION AND RESIDUAL DIFFERENCING [J].
HAMILTON, PS ;
TOMPKINS, WJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (03) :253-259
[10]   Wavelet and wavelet packet compression of electrocardiograms [J].
Hilton, ML .