COMPUTER-ASSISTED DRUG DESIGN AND SELECTION

被引:8
作者
KAMINSKI, JJ
机构
[1] Schering-Plough Research Institute, Kenilworth, NJ 07033
关键词
COMPARATIVE MOLECULAR FIELD ANALYSIS; COMFA; 3-DIMENSIONAL QUANTITATIVE STRUCTURE-ACTIVITY RELATIONSHIPS; 3D-QSAR; PARTIAL LEAST-SQUARES ANALYSIS; PLS; MOLECULAR SHAPE DESCRIPTORS; STERIC FIELD; ELECTROSTATIC FIELD; ALIGNMENT; FIELD FIT; CROSSVALIDATION; ANTIULCER AGENTS; GASTRIC PROTON PUMP INHIBITORS; H+/K+-ATPASE INHIBITORS;
D O I
10.1016/0169-409X(94)90049-3
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Comparative molecular field analysis (CoMFA), a promising new statistical and graphic three-dimensional quantitative structure-activity relationship (3D-QSAR) technique, and its potential in the drug discovery and design process are reviewed. CoMFA, a computer-assisted 3D-QSAR analysis tool, attempts to correlate molecular shape descriptors defined for a set of substrate (drug) molecules with their observed biological activities. The molecular shape descriptors for each substrate (drug) molecule are determined by analysis of the steric and electrostatic fields that surround a molecule using a test probe atom. CoMFA can also be used to predict the biological activity of unknown substrates in a series of compounds.
引用
收藏
页码:331 / 337
页数:7
相关论文
共 50 条
  • [41] No effect of obesity on limb and component alignment after computer-assisted total knee arthroplasty
    Shetty, Gautam M.
    Mullaji, Arun B.
    Bhayde, Sagar
    Lingaraju, A. P.
    KNEE, 2014, 21 (04) : 862 - 865
  • [42] Meta-Analysis of Alignment Outcomes in Computer-Assisted Total Knee Arthroplasty Surgery
    Mason, J. Bohannon
    Fehring, Thomas K.
    Estok, Rhonda
    Banel, Deirdre
    Fahrbach, Kyle
    JOURNAL OF ARTHROPLASTY, 2007, 22 (08) : 1097 - 1106
  • [43] The long-term benefit of computer-assisted surgical navigation in unicompartmental knee arthroplasty
    Konyves, Arpad
    Willis-Owen, Charles A.
    Spriggins, Anthony J.
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2010, 5
  • [44] Computer-assisted total knee arthroplasty: Does the tibial component remain at malposition risk?
    Bove, J. -C.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2010, 96 (05) : 536 - 542
  • [45] Navigation of the tibial plateau alone appears to be sufficient in computer-assisted unicompartmental knee arthroplasty
    Saragaglia, Dominique
    Picard, Frederic
    Refaie, Ramsay
    INTERNATIONAL ORTHOPAEDICS, 2012, 36 (12) : 2479 - 2483
  • [46] Medial cortical fractures in computer-assisted closing-wedge high tibial osteotomy
    Bae, Dae Kyung
    Park, Cheol Hee
    Kim, Eung Ju
    Song, Sang Jun
    KNEE, 2016, 23 (02) : 295 - 299
  • [47] A prospective study comparing the functional outcome of computer-assisted and conventional total knee replacement
    Hoffart, H-E.
    Langenstein, E.
    Vasak, N.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (02): : 194 - 199
  • [48] Medial and lateral gap laxity differential in computer-assisted kinematic total knee arthroplasty
    McEwen, P.
    Balendra, G.
    Doma, K.
    BONE & JOINT JOURNAL, 2019, 101B (03) : 331 - 339
  • [49] Factors Contributing to Patient Satisfaction and Expectations following Computer-Assisted Total Knee Arthroplasty
    Hasegawa, Masahiro
    Naito, Yohei
    Yamaguchi, Toshio
    Wakabayashi, Hiroki
    Sudo, Akihiro
    JOURNAL OF KNEE SURGERY, 2018, 31 (05) : 448 - 452
  • [50] Real-Time Multimodal Retinal Image Registration for a Computer-Assisted Laser Photocoagulation System
    Broehan, A. Martina
    Rudolph, Tobias
    Amstutz, Christoph A.
    Kowal, Jens H.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2011, 58 (10) : 2816 - 2824