MATHEMATICAL SERIES FOR SIGNAL MODELING USING EXPONENTIALLY MODIFIED FUNCTIONS

被引:29
作者
BERTHOD, A
机构
[1] Laboratoire des Sciences Analytiques, Université de Lyon 1, UA CNRS 435
关键词
D O I
10.1021/ac00017a038
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The simple recursive generating function of eq 8, with a time-dependent function, E(t), a convoluted function, U(t), corresponding to E(t), and the time interval between two measurements, DELTA-t, and a dimensionless parameter, A, linked to the time constant tau by A = tau/DELTA-t + 0.5, is demonstrated to produce U(t), which is the discrete representation of the exponentially modified E(t) function. If E(t) is a Gaussian function, then U(t) is the discrete representation of the corresponding exponentially modified Gaussian (EMG) function. The EMG function is widely used in chromatography and flow injection analysis (FIA) to model talling peaks. The proposed method can exponentially modify any Gaussian functions and/or series expansion approximations commonly used. The convolution series U(t) is defined. The link with the exponentially modified function is demonstrated for any E(t) function. The properties of the convoluted U(t) function are given. Three examples are developed: (i) the single square function whose exponentially modified form (EMS) is shown to be the equation of the one tank model in FIA; (ii) the triangle function; (iii) the Gaussian function producing the EMG function. The exponential modification of very different functions produces tailing peaks of similar general shape.
引用
收藏
页码:1879 / 1884
页数:6
相关论文
共 22 条
[1]   GRAPHICAL-METHOD FOR OBTAINING RETENTION TIME AND NUMBER OF THEORETICAL PLATES FROM TAILED CHROMATOGRAPHIC PEAKS [J].
BARBER, WE ;
CARR, PW .
ANALYTICAL CHEMISTRY, 1981, 53 (12) :1939-1942
[2]   ON THE USE OF THE KNOX EQUATION .2. THE EFFICIENCY MEASUREMENT PROBLEM [J].
BERTHOD, A .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1989, 12 (07) :1187-1201
[3]   COLUMN EFFICIENCY MEASUREMENT [J].
BIDLINGMEYER, BA ;
WARREN, FV .
ANALYTICAL CHEMISTRY, 1984, 56 (14) :A583-&
[4]   MOMENT ANALYSIS FOR EVALUATION OF FLOW-INJECTION MANIFOLDS [J].
BROOKS, SH ;
DORSEY, JG .
ANALYTICA CHIMICA ACTA, 1990, 229 (01) :35-46
[5]   SERIES FOR THE EXPONENTIALLY MODIFIED GAUSSIAN PEAK SHAPE [J].
DELLEY, R .
ANALYTICAL CHEMISTRY, 1985, 57 (01) :388-388
[6]   THE PEAK WIDTH OF NEARLY GAUSSIAN PEAKS [J].
DELLEY, R .
CHROMATOGRAPHIA, 1984, 18 (07) :374-382
[7]   A REVIEW OF THE EXPONENTIALLY MODIFIED GAUSSIAN (EMG) FUNCTION - EVALUATION AND SUBSEQUENT CALCULATION OF UNIVERSAL DATA [J].
FOLEY, JP ;
DORSEY, JG .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1984, 22 (01) :40-46
[8]   EQUATIONS FOR CHROMATOGRAPHIC PEAK MODELING AND CALCULATION OF PEAK AREA [J].
FOLEY, JP .
ANALYTICAL CHEMISTRY, 1987, 59 (15) :1984-1987
[9]   EQUATIONS FOR CALCULATION OF CHROMATOGRAPHIC FIGURES OF MERIT FOR IDEAL AND SKEWED PEAKS [J].
FOLEY, JP ;
DORSEY, JG .
ANALYTICAL CHEMISTRY, 1983, 55 (04) :730-737
[10]   COMPUTER-ASSISTED GAS-LIQUID CHROMATOGRAPHY [J].
GLADNEY, HM ;
DOWDEN, BF ;
SWALEN, JD .
ANALYTICAL CHEMISTRY, 1969, 41 (07) :883-&