SOME NOISE PROPERTIES OF 2DFT MR IMAGES FROM ASYMMETRICALLY SAMPLED DATA

被引:4
作者
HUA, JM
HURST, GC
DUERK, JL
机构
[1] CASE WESTERN RESERVE UNIV,DEPT RADIOL,CLEVELAND,OH 44106
[2] CASE WESTERN RESERVE UNIV,DEPT BIOMED ENGN,CLEVELAND,OH 44106
[3] CASE WESTERN RESERVE UNIV,DEPT CHEM,CLEVELAND,OH 44106
关键词
MRI; NOISE; ASYMMETRIC SAMPLING; RECONSTRUCTION ALGORITHMS;
D O I
10.1118/1.596920
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This report describes noise statistics in 2DFT MR images, expanding the earlier work of Henkelman and others to include variably asymmetric sampling and conjugate synthesis reconstruction. The effects of low-order polynomial and Fourier phase correction used with conjugate synthesis are also explicitly considered. This analysis shows that complex images obtained by conjugate synthesis have an elliptical noise distribution, with the smaller axis corresponding to the imaginary image channel. Derivations and simulations predict a ratio of mean to standard deviation in the background of magnitude images varying from the known value of square-root pi/(4-pi) (approximately 1.91) for full symmetry to square-rootz 2/(pi-2) (approximately 1.32) at fully asymmetric or half-echo sampling; these predictions are validated over a range of asymmetry by experimental measurements. These results are important for predicting and interpreting ima noise when using asymmetric sampling.
引用
收藏
页码:1191 / 1194
页数:4
相关论文
共 19 条
[1]  
BARTEN PGJ, 1991, SPIE P, V1453, P2
[2]   IMPROVED DETECTABILITY IN LOW SIGNAL-TO-NOISE RATIO MAGNETIC-RESONANCE IMAGES BY MEANS OF A PHASE-CORRECTED REAL RECONSTRUCTION [J].
BERNSTEIN, MA ;
THOMASSON, DM ;
PERMAN, WH .
MEDICAL PHYSICS, 1989, 16 (05) :813-817
[3]  
DEMEESTER GD, 1986, 5TH SMRM ANN M MONTR
[4]   SPIN WARP NMR IMAGING AND APPLICATIONS TO HUMAN WHOLE-BODY IMAGING [J].
EDELSTEIN, WA ;
HUTCHISON, JMS ;
JOHNSON, G ;
REDPATH, T .
PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (04) :751-756
[5]   A SIGNAL-TO-NOISE CALIBRATION PROCEDURE FOR NMR IMAGING-SYSTEMS [J].
EDELSTEIN, WA ;
BOTTOMLEY, PA ;
PFEIFER, LM .
MEDICAL PHYSICS, 1984, 11 (02) :180-185
[6]   HALVING MR IMAGING TIME BY CONJUGATION - DEMONSTRATION AT 3.5 KG [J].
FEINBERG, DA ;
HALE, JD ;
WATTS, JC ;
KAUFMAN, L ;
MARK, A .
RADIOLOGY, 1986, 161 (02) :527-531
[7]  
FUDERER M, 1989, 8TH SMRM ANN M AMST
[8]   IMPROVED CONTRAST AT 1.5 TESLA USING HALF-FOURIER IMAGING - APPLICATION TO SPIN-ECHO AND ANGIOGRAPHIC IMAGING [J].
HAACKE, EM ;
MITCHELL, J ;
LEE, DH .
MAGNETIC RESONANCE IMAGING, 1990, 8 (01) :79-90
[9]   MEASUREMENT OF SIGNAL INTENSITIES IN THE PRESENCE OF NOISE IN MR IMAGES [J].
HENKELMAN, RM .
MEDICAL PHYSICS, 1985, 12 (02) :232-233
[10]   NOISE AND ARTIFACT COMPARISON FOR FOURIER AND POLYNOMIAL PHASE CORRECTION USED WITH FOURIER RECONSTRUCTION OF ASYMMETRIC DATA SETS [J].
HUA, JM ;
HURST, GC .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (03) :347-353