Optimal Matrix Preparation Methods for Matrix-assisted Laser Desorption/ionisation Time-of-flight Mass Spectrometry Profiling of Low Molecular Weight Peptides in Human Saliva and Serum Samples

被引:1
作者
Gao, Lu [1 ]
Gu, Yan [1 ]
Chen, Feng [2 ]
Ma, Qing Wei [3 ]
机构
[1] Peking Univ, Natl Engn Lab Digital & Mat Technol Stomatol, Beijing Key Lab Digital Stomatol, Dept Orthodont,Sch & Hosp Stomatol, Beijing, Peoples R China
[2] Peking Univ, Natl Engn Lab Digital & Mat Technol Stomatol, Beijing Key Lab Digital Stomatol, Cent Lab,Sch & Hosp Stomatol, Beijing, Peoples R China
[3] BioyongTech Technol Corp, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
MALDI-TOF MS; matrix preparation; proteomics; peptides; saliva;
D O I
10.3290/j.cjdr.a39918
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To develop standard experimental methods to minimise technical variance in matrix preparation for MALDI-TOF MS (matrix-assisted laser desorption/ionisation time-of-flight) profiling. Methods: Matrix factors in saliva and serum samples of 20 healthy volunteers were examined, assuring their peptide components using seven different matrix type/preparation methods, HCCA(a-cyano-4-hydroxycinnamic acid)/SM(sample/matrix), SA(sinapinic acid)/DD(dried droplet), SA/SM, DHB(2.5-dihydroxyhenz-zoic acid)/DD, DHB/SM, DHAP(2.5-dihydroxyacetophenone)/ DD, DHAP/SM. Number of peaks, S/N(signal to noise) ratio and approximate range of target peaks were set as main selection criteria to find if these spell out any common regularity in results. Results: Different methods perform differently. DHB/DD performed worst in both samples, with no effective peak detected. For saliva sample, the S/N ratios of other six methods were lower. M/z range distributed differently. DHB/SM and DHAP/DD performed best in number of peaks, m/z distributing in 1000 to 2000 account for the vast majority. For serum sample, S/N ratios and m/z range distribution were different in different methods. S/N ratio of SA/DD and SA/SM were higher, number of peaks and m/z distribution were not irreplaceable. S/N ratios of the other four methods were lower. Conclusion: DHAP/DD and HCCA/SM performed best in number of peaks, m/z in 5000 7000 account for the vast majority in HCCA/SM and 1000 - 2000 in DHAP/DD. Further studies should focus on other characteristics of peptide components detected in different matrix methods to increase evidence when selecting matrix type/preparation methods.
引用
收藏
页码:51 / 61
页数:11
相关论文
共 36 条
[1]   Standardized approach to proteome profiling of human serum based on magnetic bead separation and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry [J].
Baumann, S ;
Ceglarek, U ;
Fiedler, GM ;
Lembcke, J ;
Leichtle, A ;
Thiery, J .
CLINICAL CHEMISTRY, 2005, 51 (06) :973-980
[2]   Proteomic profiling using mass spectrometry does normalising by total ion current potentially mask some biological differences? [J].
Cairns, David A. ;
Thompson, Douglas ;
Perkins, David N. ;
Stanley, Anthea J. ;
Selby, Peter J. ;
Banks, Rosamonde E. .
PROTEOMICS, 2008, 8 (01) :21-27
[3]   Serum protein profiling by miniaturized solid-phase extraction and matrix-assisted laser desorption/ionization mass spectrometry [J].
Callesen, AK ;
Mohammed, S ;
Bunkenborg, J ;
Kruse, TA ;
Cold, S ;
Mogensen, O ;
Christensen, RD ;
Vach, W ;
Jorgensen, PE ;
Jensen, ON .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (12) :1578-1586
[4]   Combined experimental and statistical strategy for mass spectrometry based serum protein profiling for diagnosis of breast cancer: A case-control study [J].
Callesen, Anne K. ;
Vach, Werner ;
Jorgensen, Per E. ;
Cold, Soren ;
Tan, Qihua ;
Christensen, Rene dePont ;
Mogensen, Ole ;
Kruse, Torbert A. ;
Jensen, Ole N. ;
Madsen, Jonna S. .
JOURNAL OF PROTEOME RESEARCH, 2008, 7 (04) :1419-1426
[5]   MALDI-TOF mass spectrometry tools for bacterial identification in clinical microbiology laboratory [J].
Carbonnelle, Etienne ;
Mesquita, Cecile ;
Bille, Emmanuelle ;
Day, Nesrine ;
Dauphin, Brunhilde ;
Beretti, Jean-Luc ;
Ferroni, Agnes ;
Gutmann, Laurent ;
Nassif, Xavier .
CLINICAL BIOCHEMISTRY, 2011, 44 (01) :104-109
[6]   Improved peak detection and quantification of mass spectrometry data acquired from surface-enhanced laser desorption and ionization by denoising spectra with the undecimated discrete wavelet transform [J].
Coombes, KR ;
Tsavachidis, S ;
Morris, JS ;
Baggerly, KA ;
Hung, MC ;
Kuerer, HM .
PROTEOMICS, 2005, 5 (16) :4107-4117
[7]   Standardized peptidome profiling of human urine by magnetic bead separation and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry [J].
Fiedler, Georg Martin ;
Baumann, Sven ;
Leichtle, Alexander ;
Oltmann, Anke ;
Kase, Julia ;
Thiery, Joachim ;
Ceglarek, Uta .
CLINICAL CHEMISTRY, 2007, 53 (03) :421-428
[8]   Preanalytical impact of sample handling on proteome profiling experiments with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry [J].
Findeisen, P ;
Sismanidis, D ;
Riedl, M ;
Costina, V ;
Neumaier, M .
CLINICAL CHEMISTRY, 2005, 51 (12) :2409-2411
[9]   Discovery and verification of urinary peptides in type 2 diabetes mellitus with kidney injury [J].
Fu, Guangzhen ;
Du, Ye ;
Chu, Lina ;
Zhang, Man .
EXPERIMENTAL BIOLOGY AND MEDICINE, 2016, 241 (11) :1186-1194
[10]   Optimization of MALDI-TOF MS detection for enhanced sensitivity of affinity-captured proteins spanning a 100 kDa mass range [J].
Gatlin-Bunai, Christine L. ;
Cazares, Lisa H. ;
Cooke, William E. ;
Semmes, Oliver J. ;
Malyarenko, Dariya I. .
JOURNAL OF PROTEOME RESEARCH, 2007, 6 (11) :4517-4524