Body Composition in Obese Adolescents: Deuterium Oxide Dilution Method, Bioelectrical Impedance and Predictive Equations

被引:5
作者
Mendes Resende, Cristina Maria [1 ]
Camelo Junior, Jose Simon [1 ]
Campanelli Marcal Vieira, Marta Neves [1 ]
Castro Perdon, Gleici da Silva [2 ]
Ferriolli, Eduardo [3 ]
Pfrimer, Karina [3 ]
Mathias, Mariana Giaretta [1 ]
Monteiro, Jacqueline Pontes [1 ]
机构
[1] Univ Sao Paulo, Sch Med Ribeirao Preto, Dept Pediat, Av Bandeirantes 3900, BR-14049900 Ribeirao Preto, SP, Brazil
[2] Univ Sao Paulo Ribeirao Preto, Sch Med Ribeirao Preto, Dept Social Med, Sao Paulo, Brazil
[3] Univ Sao Paulo, Sch Med Ribeirao Preto, Dept Internal Med, Lab Mass Spectrometry, Ribeirao Preto, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Adolescents; bioelectrical impedance; body composition; deuterium oxide dilution method; obesity;
D O I
10.2174/1573401311309010012
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Background & Aims: Considering that obese adolescents present alterations in the quantity of body water, fat and lean body mass, specific formulae need to be adjusted through a reference method. This study aimed to describe and compare the body composition data obtained by bioelectrical impedance analysis (BIA) and the deuterium oxide dilution method (DODM). To identify possible correlations and agreement between these two techniques and adjust linear regression models for the prediction of DODM values on the basis of BIA results. Methods: Anthropometric measurements were accomplished for obese adolescents, and their body composition was assessed by the BIA and DODM techniques. Results: Compared to the DODM technique, BIA overestimated the fat-free mass (FFM) and the total body water (TBW) and underestimated the fat mass (FM). There was a significant positive correlation but no agreement between the FFM (kg), FM (kg), and TBW (L) data achieved via DODM and BIA. The application of linear regression model adjustments to the values measured by BIA enabled prediction of the DODM values for body composition in obese adolescents. Conclusion: These formulas have been demonstrated to improve the agreement between the two methods, so a more accurate tool that is closer to the DODM reference technique has been made available for use in clinical practice.
引用
收藏
页码:73 / 81
页数:9
相关论文
共 43 条
[11]  
Dioum A, 2005, AM J CLIN NUTR, V81, P597
[12]   Underestimation of percentage fat mass measured by bioelectrical impedance analysis compared to dual energy X-ray absorptiometry method in obese children [J].
Eisenkölbl, J ;
Kartasurya, M ;
Widhalm, K .
EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2001, 55 (06) :423-429
[13]   Assessing body composition among 3-to 8-year-old children: Anthropometry, BIA, and DXA [J].
Eisenmann, JC ;
Heelan, KA ;
Welk, GJ .
OBESITY RESEARCH, 2004, 12 (10) :1633-1640
[14]  
Eisenstein E, 2000, J PEDIAT, V76, P263
[15]   Evaluation of body composition in neonates and infants [J].
Ellis, Kenneth J. .
SEMINARS IN FETAL & NEONATAL MEDICINE, 2007, 12 (01) :87-91
[16]   Human body composition: In vivo methods [J].
Ellis, KJ .
PHYSIOLOGICAL REVIEWS, 2000, 80 (02) :649-680
[17]  
Ferrioli E, 2008, CIENCIAS NUTRICIONAI, V23, P443
[18]   VALIDATION OF THE DEUTERIUM-OXIDE METHOD FOR MEASURING AVERAGE DAILY MILK INTAKE IN INFANTS [J].
FJELD, CR ;
BROWN, KH ;
SCHOELLER, DA .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1988, 48 (03) :671-679
[19]  
HEYMSFIELD SB, 1994, MODERN NUTR HLTH DIS, P812
[20]  
HOUTKOOPER LB, 1992, J APPL PHYSIOL, V72, P366