COMPARISON OF MULTIVARIATE METHODS BASED ON LATENT VECTORS AND METHODS BASED ON WAVELENGTH SELECTION FOR THE ANALYSIS OF NEAR-INFRARED SPECTROSCOPIC DATA

被引:106
作者
JOUANRIMBAUD, D
WALCZAK, B
MASSART, DL
LAST, IR
PREBBLE, KA
机构
[1] FREE UNIV BRUSSELS,INST PHARMACEUT,CHEMOAC,B-1090 BRUSSELS,BELGIUM
[2] WELLCOME FDN LTD,ANALYT DEV LABS,DARTFORD DA1 5AH,KENT,ENGLAND
关键词
PRINCIPAL COMPONENT ANALYSIS; INFRARED SPECTROMETRY; CALIBRATION METHODS;
D O I
10.1016/0003-2670(94)00590-I
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Comparison of several calibration methods (principal component regression (PCR), partial least-squares, multiple linear regression), with and without feature selection, applied on near-infrared spectroscopic data is presented for a pharmaceutical application. It is shown that PCR with selection of principal components instead of the usual top-down approach yields simpler and better models. As feature selection methods, selection of wavelengths correlated with concentration, with large covariance with concentration, with high loadings on the important principal components, and according to a method proposed by Brown, are considered. The presented results suggests that feature selection can improve multivariate calibration.
引用
收藏
页码:285 / 295
页数:11
相关论文
共 13 条
[1]   GENERATING OPTIMAL LINEAR PLS ESTIMATIONS (GOLPE) - AN ADVANCED CHEMOMETRIC TOOL FOR HANDLING 3D-QSAR PROBLEMS [J].
BARONI, M ;
COSTANTINO, G ;
CRUCIANI, G ;
RIGANELLI, D ;
VALIGI, R ;
CLEMENTI, S .
QUANTITATIVE STRUCTURE-ACTIVITY RELATIONSHIPS, 1993, 12 (01) :9-20
[2]   WAVELENGTH SELECTION IN MULTICOMPONENT NEAR-INFRARED CALIBRATION [J].
BROWN, PJ .
JOURNAL OF CHEMOMETRICS, 1992, 6 (03) :151-161
[3]  
DRAPER NR, 1981, APPLIED REGRESSION A
[4]   MULTICOMPONENT DETERMINATION OF FLAVOR ENHANCERS IN FOOD PREPARATIONS BY PARTIAL LEAST-SQUARES AND PRINCIPAL COMPONENT REGRESSION MODELING OF SPECTROPHOTOMETRIC DATA [J].
DURANMERAS, I ;
DELAPENA, AM ;
ESPINOSAMANSILLA, A ;
SALINAS, F .
ANALYST, 1993, 118 (07) :807-813
[5]   CROSS-VALIDATORY CHOICE OF THE NUMBER OF COMPONENTS FROM A PRINCIPAL COMPONENT ANALYSIS [J].
EASTMENT, HT ;
KRZANOWSKI, WJ .
TECHNOMETRICS, 1982, 24 (01) :73-77
[6]  
GELADI P, 1986, ANAL CHIM ACTA, V1185, P1
[7]   PARTIAL LEAST-SQUARES METHODS FOR SPECTRAL ANALYSES .1. RELATION TO OTHER QUANTITATIVE CALIBRATION METHODS AND THE EXTRACTION OF QUALITATIVE INFORMATION [J].
HAALAND, DM ;
THOMAS, EV .
ANALYTICAL CHEMISTRY, 1988, 60 (11) :1193-1202
[8]   PARTIAL LEAST-SQUARES METHODS FOR SPECTRAL ANALYSES .2. APPLICATION TO SIMULATED AND GLASS SPECTRAL DATA [J].
HAALAND, DM ;
THOMAS, EV .
ANALYTICAL CHEMISTRY, 1988, 60 (11) :1202-1208
[9]  
MACLAURIN P, 1992, ANAL PROC, V29, P65
[10]  
Martens H, 1991, MULTIVARIATE CALIBRA