Virtual fluoroscopy for intraoperative C-arm positioning and radiation dose reduction

被引:17
作者
De Silva, Tharindu [1 ]
Punnoose, Joshua [1 ]
Uneri, Ali [1 ]
Mahesh, Mahadevappa [2 ]
Goerres, Joseph [1 ]
Jacobson, Matthew [1 ]
Ketcha, Michael D. [1 ]
Manbachi, Amir [1 ]
Vogt, Sebastian [3 ]
Kleinszig, Gerhard [3 ]
Khanna, Akhil Jay [4 ]
Wolinksy, Jean-Paul [5 ]
Siewerdsen, Jeffrey H. [1 ,2 ,5 ]
Osgood, Greg [4 ]
机构
[1] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21218 USA
[2] Johns Hopkins Univ, Russell H Morgan Dept Radiol, Baltimore, MD 21218 USA
[3] Siemens Healthineers, Erlangen, Germany
[4] Johns Hopkins Univ, Orthopaed Surg, Baltimore, MD USA
[5] Johns Hopkins Univ, Dept Neurosurg, Baltimore, MD 21218 USA
关键词
3D-2D registration; image-guided surgery; orthopedic surgery; digitally reconstructed radiographs; virtual fluoroscopy;
D O I
10.1117/1.JMI.5.1.015005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Positioning of an intraoperative C-arm to achieve clear visualization of a particular anatomical feature often involves repeated fluoroscopic views, which cost time and radiation exposure to both the patient and surgical staff. A system for virtual fluoroscopy (called FluoroSim) that could dramatically reduce time-and dosespent "fluoro-hunting" by leveraging preoperative computed tomography (CT), encoded readout of C-arm gantry position, and automatic 3D-2D image registration has been developed. The method is consistent with existing surgical workflow and does not require additional tracking equipment. Real-time virtual fluoroscopy was achieved via mechanical encoding of the C-arm motion, C-arm geometric calibration, and patient registration using a single radiograph. The accuracy, time, and radiation dose associated with C-arm positioning were measured for FluoroSim in comparison with conventional methods. Five radiology technologists were tasked with acquiring six standard pelvic views pertinent to sacro-illiac, anterior-inferior iliac spine, and superior-ramus screw placement in an anthropomorphic pelvis phantom using conventional and FluoroSim approaches. The positioning accuracy, exposure time, number of exposures, and total time for each trial were recorded, and radiation dose was characterized in terms of entrance skin dose and in-room scatter. The geometric accuracy of FluoroSim was measured to be 1.6 +/- 1.1 mm. There was no significant difference (p > 0.05) observed in the accuracy or total elapsed time for C-arm positioning. However, the total fluoroscopy time required to achieve the desired view decreased by 4.1 s (4.7 +/- 3.6 s for conventional, compared with 0.5 +/- 0.0 s for FluoroSim, p < 0.05), and the total number of exposures reduced by 4.0 (6.4 +/- 4.8 for conventional, compared with 2.0 +/- 0.0 for FluoroSim, p < 0.05). These reductions amounted to a 50% to 78% decrease in patient entrance skin dose and a 55% to 70% reduction in in-room scatter. FluoroSim was found to reduce the radiation exposure required in C-arm positioning without diminishing positioning time or accuracy, providing a potentially valuable tool to assist technologists and surgeons. (c) 2018 Society of Photo-Optical Instrumentation Engineers (SPIE).
引用
收藏
页数:8
相关论文
共 22 条
  • [1] Bott OJ, 2011, RADIOGRAPHICS, V31, pE31, DOI [10.1148/rg.313105125, 10.1148/rg.313105125/-/DC1]
  • [2] Cabral B., 1994, P 1994 S VOL VIS, P91, DOI DOI 10.1145/197938.197972
  • [3] 3D-2D image registration for target localization in spine surgery: investigation of similarity metrics providing robustness to content mismatch
    De Silva, T.
    Uneri, A.
    Ketcha, M. D.
    Reaungamornrat, S.
    Kleinszig, G.
    Vogt, S.
    Aygun, N.
    Lo, S-F
    Wolinsky, J-P
    Siewerdsen, J. H.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (08) : 3009 - 3025
  • [4] Utility of the LevelCheck Algorithm for Decision Support in Vertebral Localization
    De Silva, Tharindu
    Lo, Sheng-Fu L.
    Aygun, Nafi
    Aghion, Daniel M.
    Boah, Akwasi
    Petteys, Rory
    Uneri, Ali
    Ketcha, Michael D.
    Yi, Thomas
    Vogt, Sebastian
    Kleinszig, Gerhard
    Wei, Wei
    Weiten, Markus
    Ye, Xiaobu
    Bydon, Ali
    Sciubba, Daniel M.
    Witham, Timothy F.
    Wolinsky, Jean-Paul
    Siewerdsen, Jeffrey H.
    [J]. SPINE, 2016, 41 (20) : E1249 - E1256
  • [5] Intraoperative Positioning of Mobile C-arms using Artificial Fluoroscopy
    Dressel, Philipp
    Wang, Lejing
    Kutter, Oliver
    Traub, Joerg
    Heining, Sandro-Michael
    Navab, Nassir
    [J]. MEDICAL IMAGING 2010: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2010, 7625
  • [6] Goerres J., 2017, P SOC PHOTO-OPT INS
  • [7] A Cost Effective and High Fidelity Fluoroscopy Simulator using the Image-Guided Surgery Toolkit (IGSTK)
    Gong, Ren Hui
    Jenkins, Brad
    Sze, Raymond W.
    Yaniv, Ziv
    [J]. MEDICAL IMAGING 2014: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2014, 9036
  • [8] Hansen N, 2006, STUD FUZZ SOFT COMP, V192, P75
  • [9] Multi-stage 3D-2D registration for correction of anatomical deformation in image-guided spine surgery
    Ketcha, M. D.
    De Silva, T.
    Uneri, A.
    Jacobson, M. W.
    Goerres, J.
    Kleinszig, G.
    Vogt, S.
    Wolinsky, J-P
    Siewerdsen, J. H.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (11) : 4604 - 4622
  • [10] Automatic Masking for Robust 3D-2D Image Registration in Image-Guided Spine Surgery
    Ketcha, M. D.
    De Silva, T.
    Uneri, A.
    Kleinszig, G.
    Vogt, S.
    Wolinsky, J. -P.
    Siewerdsen, J. H.
    [J]. MEDICAL IMAGING 2016: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2016, 9786