Comparative Study of Poly(Vinyl Chloride) Based Polymeric Membrane Sensors for the Determination of Erbium (III)

被引:0
作者
Singh, Arpit [1 ]
Singh, Sanjay [2 ]
Singh, Gyanendra [1 ]
机构
[1] Mahanand Miss Harijan Coll, Dept Chem, Ghaziabad 201001, UP, India
[2] Mewar Univ, Dept Chem, Chittaurgarh 312901, Rajasthan, India
来源
ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY | 2012年 / 4卷 / 03期
关键词
Sensor; Potentiometry; Ionophore; Erbium; Selectivity;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The three chelates 1,5-bis(o-aminobenzoate)-3-thiapentane (L-1), 1,5-bis(o-methoxybenzoate)- 3-thiapentane (L-2), 1,5-bis(o-chlorobenzoate)-3-thiapentane (L-3) have been synthesized and explored as a neutral ionophores for preparing poly(vinyl chloride) based membrane sensors selective to Er3+. The addition of sodiumtetraphenylborate and various plasticizers, viz., o-NPOE, TBP, DBBP, TEP and DOS has been found to substantially improve the performance of the sensor. The best performance was obtained with the sensor no. 6 having membrane of ionophore (L-2) with composition PVC: o-NPOE: ionophore (L-2): NaTPB (% w/w) of 35:56:2:7. This sensor exhibits Nernstian response with slope 22.1 +/- 0.3 mV decade(-1) of activity in concentration range 3.0x10(-9) to 1.0x10(-2) M Er3+, performs satisfactorily over wide pH range (1.5-6.7), with a fast response time (8 s). The sensor was also found to work satisfactorily in partially non-aqueous media up to 20% content of methanol, ethanol or acetone and could be used for a period of 5 months without any change in response characteristics. The Er3+ selective sensor was used as an indicator electrode for the titration of 25 ml 1 x 10(-3) M EDTA solution and for the determination of Er3+ ion in different synthetic samples. The proposed electrode no. 6 was also used for the determination of fluoride ion in two mouth wash sample.
引用
收藏
页码:296 / 314
页数:19
相关论文
共 37 条
[1]  
An BL, 1999, RARE METAL MAT ENG, V28, P333
[2]   NEUTRAL CARRIER BASED ION-SELECTIVE ELECTRODE FOR THE DETERMINATION OF TOTAL CALCIUM IN BLOOD-SERUM [J].
ANKER, P ;
WIELAND, E ;
AMMANN, D ;
DOHNER, RE ;
ASPER, R ;
SIMON, W .
ANALYTICAL CHEMISTRY, 1981, 53 (13) :1970-1974
[3]   PVC MATRIX MEMBRANE ION-SELECTIVE ELECTRODES - CONSTRUCTION AND LABORATORY EXPERIMENTS [J].
CRAGGS, A ;
MOODY, GJ ;
THOMAS, JDR .
JOURNAL OF CHEMICAL EDUCATION, 1974, 51 (08) :541-544
[4]   EVALUATION OF CALCIUM ION-SELECTIVE ELECTRODES BASED ON DI(N-ALKYLPHENYL)PHOSPHATE SENSORS AND THEIR CALIBRATION WITH ION BUFFERS [J].
CRAGGS, A ;
MOODY, GJ ;
THOMAS, JDR .
ANALYST, 1979, 104 (1238) :412-418
[5]   Simultaneous determination of neodymium and samarium in silicate rocks and minerals by isotope dilution inductively coupled plasma mass spectrometry: Results on twenty geochemical reference samples [J].
D'Orazio, M ;
Tonarini, S .
ANALYTICA CHIMICA ACTA, 1997, 351 (1-3) :325-335
[6]  
Debye P, 1923, PHYS Z, V24, P305
[7]   DETERMINATION AND APPLICATION OF ION-SELECTIVE ELECTRODE MODEL PARAMETERS USING FLOW-INJECTION AND SIMPLEX OPTIMIZATION [J].
DEVITERI, FJS ;
DIAMOND, D .
ANALYST, 1994, 119 (05) :749-758
[8]   Application of pyridine-2-carbaldehyde-2-(4-methyl-1,3-benzo thiazol-2-yl) hydrazone as a neutral ionophore in the construction of a novel Er(III) sensor [J].
Ganjali, Mohammad Reza ;
Rezapour, Morteza ;
Rasoolipour, Solmaz ;
Norouzi, Parviz ;
Adib, Mehdi .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2007, 18 (02) :352-358
[9]   Novel ytterbium(III) selective membrane sensor based on N-(2-pyridyl)-N′-(2-methoxyphenyl)-thiourea as an excellent carrier and its application to determination of fluoride in mouth wash preparation samples [J].
Ganjali, MR ;
Rasoolipour, S ;
Rezapour, M ;
Norouzi, P ;
Tajarodi, A ;
Hanifehpour, Y .
ELECTROANALYSIS, 2005, 17 (17) :1534-1539
[10]  
Gschneidner K.A., 1978, HDB PHYS CHEM RARE E