STANDARD POTENTIAL VALUES OF CYANIDE-SENSITIVE SILVER-IODIDE AND SILVER SULFIDE ION-SELECTIVE ELECTRODES

被引:7
|
作者
JOVANOVIC, VM [1 ]
JOVANOVIC, MS [1 ]
机构
[1] UNIV BELGRADE,FAC TECHNOL & MET,DEPT ANALYT CHEM,YU-11001 BELGRADE,YUGOSLAVIA
关键词
D O I
10.1016/S0003-2670(00)83499-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
It is shown that the equation for the potentials of semiconductive sulphide membranes given by Sato 25 years ago is valid also for the calculation of E0 values of "cyanide-sensitive" ion-selective electrodes. The only requirement for such an approach to the problem is information on the activities of relevant species in both the solid and the liquid phases. In this way, the E0 value given by Pungor and Toth for the silver iodide membrane in cyanide solution was confirmed, and E0 for silver sulphide in cyanide solution was evaluated for the first time. © 1990.
引用
收藏
页码:329 / 333
页数:5
相关论文
共 50 条
  • [11] ION-SELECTIVE ELECTRODES FOR GOLD AND SILVER DETERMINATION
    PETRUKHIN, OM
    AVDEEVA, EN
    SHAVNYA, YV
    YANKAUSKAS, VP
    KAZLAUSKAS, RM
    BYCHKOV, AS
    ZOLOTOV, YA
    TALANTA, 1987, 34 (01) : 111 - 121
  • [12] POTENTIOMETRIC TITRATION OF SILVER WITH ION-SELECTIVE ELECTRODES
    GEISSLER, M
    ANALYTICA CHIMICA ACTA, 1977, 90 (MAY) : 249 - 252
  • [13] BEHAVIOR OF SILVER SULFIDE PRECIPITATE BASED ION-SELECTIVE ELECTRODES IN THE LOW CONCENTRATION RANGE
    GRAFHARSANYI, E
    TOTH, K
    PUNGOR, E
    MAGYAR KEMIAI FOLYOIRAT, 1986, 92 (11-12): : 545 - 551
  • [14] BEHAVIOR OF ION-SELECTIVE ELECTRODES BASED ON SILVER OR MERCURIC SULFIDE SELENIDE AND TELLURIDE MATRICES
    SEKERKA, I
    LECHNER, JF
    ANALYTICAL LETTERS, 1976, 9 (12) : 1099 - 1110
  • [15] OBSERVATIONS ON CALIBRATION OF SOLID-STATE SILVER SULFIDE MEMBRANE ION-SELECTIVE ELECTRODES
    CROMBIE, DJ
    MOODY, GJ
    THOMAS, JDR
    ANALYTICA CHIMICA ACTA, 1975, 80 (NOV) : 1 - 8
  • [16] AUTOMATED IMMUNOASSAY WITH A SILVER SULFIDE ION-SELECTIVE ELECTRODE
    SOLSKY, RL
    RECHNITZ, GA
    ANALYTICA CHIMICA ACTA, 1978, 99 (02) : 241 - 246
  • [17] DETERMINATION OF AMINES WITH AN ION-SELECTIVE SILVER SULFIDE ELECTRODE
    OBTEMPERANSKAYA, SI
    RASHID, S
    BUZLANOVA, MM
    ZHMUROVA, NV
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1986, 41 (02): : 301 - 302
  • [18] PLASTICIZED ION-SELECTIVE ELECTRODE FOR DETERMINING SILVER IN CYANIDE SOLUTIONS
    YANKAUSKAS, VP
    AVDEEVA, EN
    KAZLAUSKAS, RM
    PETRUKHIN, OM
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1983, 38 (04): : 485 - 490
  • [19] CHEMICAL PRETREATMENT OF SILVER WIRE CONTAINING COPPER FOR PREPARATION OF SILVER SILVER SULFIDE ION-SELECTIVE ELECTRODE
    RADIC, N
    MULLIGAN, KJ
    MARK, HB
    ANALYTICAL CHEMISTRY, 1984, 56 (02) : 297 - 298
  • [20] SURFACE STUDIES OF THE SILVER SULFIDE ION-SELECTIVE ELECTRODE MEMBRANE
    DEMARCO, R
    CATTRALL, RW
    LIESEGANG, J
    NYBERG, GL
    HAMILTON, IC
    ANALYTICAL CHEMISTRY, 1990, 62 (21) : 2339 - 2346