VOLTAMMETRIC BEHAVIOR OF SCREEN-PRINTED CARBON ELECTRODES, CHEMICALLY MODIFIED WITH SELECTED MEDIATORS, AND THEIR APPLICATION AS SENSORS FOR THE DETERMINATION OF REDUCED GLUTATHIONE

被引:72
|
作者
WRING, SA
HART, JP
BIRCH, BJ
机构
[1] BRISTOL POLYTECH,DEPT SCI,COLDHARBOUR LANE,BRISTOL BS16 1QY,ENGLAND
[2] UNILEVER RES LABS,SENSORS GRP,SHARNBROOK MK44 1LQ,BEDS,ENGLAND
关键词
SCREEN-PRINTED CARBON ELECTRODES; CHEMICALLY MODIFIED FERROCENE; PHTHALOCYANINE AND HEXACYANOFERRATE(III) MEDIATO; REDUCED GLUTATHIONE; CYCLIC VOLTAMMETRY; AMPEROMETRY;
D O I
10.1039/an9911600123
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The evaluation of screen-printed carbon electrodes, chemically modified with selected ferrocene, phthalocyanine and hexacyanoferrate(III) derivative mediators for the determination of reduced glutathione (GSH), is described. Cyclic voltammetry was used to investigate the effect of pH on the electrochemical behaviour of these mediators incorporated in the disposable electrodes. Values of the electron-transfer coefficient (alpha-n(a)) were calculated for the oxidation of the mediators in phosphate buffer solution and solutions containing 0.48 mmol dm-3 GSH. Amperometry in stirred solutions was used to construct hydrodynamic voltammograms for each of the modified electrodes; these voltammograms were used to elucidate their steady-state behaviour. Both electrochemical techniques were used to calculate the reduction in overpotential for the oxidation of GSH; these calculations were performed for all of the chemically modified electrodes. Amperometry in stirred solutions was used as the technique for quantitative measurements, to determine the calibration response factors (mu-A mmol-1 dm3) and limits of detection for selected mediators towards GSH. The appropriate applied potentials were selected by reference to the hydrodynamic waves; a range of values were investigated to find the potential that gave the maximum sensitivity. The most promising mediators were cobalt phthalocyanine, iron phthalocyanine and ferrocenecarbaldehyde.
引用
收藏
页码:123 / 129
页数:7
相关论文
共 50 条
  • [1] Voltammetric Determination of Phenylalanine Using Chemically Modified Screen-Printed Based Sensors
    Dinu, Ancuta
    Apetrei, Constantin
    CHEMOSENSORS, 2020, 8 (04) : 1 - 18
  • [2] CHEMICALLY MODIFIED, SCREEN-PRINTED CARBON ELECTRODES
    WRING, SA
    HART, JP
    ANALYST, 1992, 117 (08) : 1281 - 1286
  • [3] Voltammetric Determination of Levodopa Using Mesoporous Carbon-Modified Screen-Printed Carbon Sensors
    Dascalescu, Dorin
    Apetrei, Constantin
    SENSORS, 2021, 21 (18)
  • [4] Voltammetric Determination of Anticancer Drug Flutamide at Screen-Printed Carbon Electrodes
    Vyskocil, Vlastimil
    Navratil, Tomas
    Barek, Jiri
    MODERN ELECTROCHEMICAL METHODS XXXI, 2011, : 190 - 194
  • [5] Comparative voltammetric behavior of indigo carmine at screen-printed carbon electrodes
    Díaz-González, M
    Fernández-Sánchez, C
    Costa-García, A
    ELECTROANALYSIS, 2002, 14 (10) : 665 - 670
  • [6] Chemically modified platinum screen-printed electrodes for electrochemical detection of acetylene
    Izumi, F.
    de Souza, C. A. A.
    dos Santos Filho, S. G.
    Gongora-Rubio, M. R.
    2016 31ST SYMPOSIUM ON MICROELECTRONICS TECHNOLOGY AND DEVICES (SBMICRO), 2016,
  • [7] Facile Fabrication of Screen-Printed Carbon Electrodes for Electrochemical Sensors
    Sarmphim, P.
    Teeparuksapun, K.
    Wunsri, S.
    Sorngodchagorn, S.
    Duangsiri, W.
    Tapparak, P.
    Sirisathitkul, C.
    INTERNATIONAL JOURNAL OF NANOELECTRONICS AND MATERIALS, 2021, 14 (01): : 1 - 10
  • [8] Electrochemical determination of propranolol by using modified screen-printed electrodes
    Mohammadi, Sayed Zia
    Tajik, Somayeh
    Beitollahi, Hadi
    INDIAN JOURNAL OF CHEMICAL TECHNOLOGY, 2020, 27 (01) : 73 - 78
  • [9] Nanodiamond based surface modified screen-printed electrodes for the simultaneous voltammetric determination of dopamine and uric acid
    Baccarin, Marina
    Rowley-Neale, Samuel J.
    Cavalheiro, Eder T. G.
    Smith, Graham C.
    Banks, Craig E.
    MICROCHIMICA ACTA, 2019, 186 (03)
  • [10] Voltammetric determination of urinary 1-hydroxypyrene using molecularly imprinted polymer-modified screen-printed carbon electrodes
    Kirsch, N
    Honeychurch, KC
    Hart, JP
    Whitcombe, MJ
    ELECTROANALYSIS, 2005, 17 (07) : 571 - 578