SIMPLE AND RAPID HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY METHOD FOR THE DETERMINATION OF ALCURONIUM IN HUMAN PLASMA AND URINE

被引:2
|
作者
KUNZER, T
BUZELLO, CW
THEISOHN, M
DIEFENBACH, C
机构
[1] UNIV COLOGNE,DEPT PHARMACOL,D-50924 COLOGNE,GERMANY
[2] UNIV COLOGNE,DEPT ANAESTHESIOL,D-50924 COLOGNE,GERMANY
来源
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS | 1994年 / 653卷 / 01期
关键词
D O I
10.1016/0378-4347(93)E0426-Q
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple and quick HPLC assay for alcuronium is presented. Its characteristics are: precipitation of plasma proteins by acetonitrile; Spherisorb 5-CN column; acetonitrile-water (46:54, v/v) as mobile phase; flow-rate 1 ml/min; laudanosine 0.06 mg/l as internal standard with plasma; external standard with urine; UV detection at 294 nm; retention time 5.4 min; detection limit 0.025 mg/l; documented linearity: 0.025-2.0 mg/l for plasma and 1.0-80 mg/l for urine; intra- and inter-assay variability below 4%. None of nine drugs used in perioperative pharmacotherapy interfered with the assay. Satisfactory performance was exemplified in a 12-h pharmacokinetic evaluation of two patients.
引用
收藏
页码:63 / 68
页数:6
相关论文
共 50 条
  • [1] DETERMINATION OF ALCURONIUM IN PLASMA AND URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    DEBROS, F
    OKUTANI, R
    INADA, E
    LAWRENCE, K
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 529 (02): : 449 - 454
  • [2] SIMPLE DETERMINATION OF HYDROCHLOROTHIAZIDE IN HUMAN PLASMA AND URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    DEVRIES, JX
    VOSS, A
    BIOMEDICAL CHROMATOGRAPHY, 1993, 7 (01) : 12 - 14
  • [3] RAPID-DETERMINATION OF XIPAMIDE IN HUMAN PLASMA AND URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    BODENAN, S
    PAILLET, M
    CHRISTEN, MO
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 533 : 275 - 281
  • [4] RAPID METHOD FOR DETERMINATION OF RIBOFLAVIN IN URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    SMITH, MD
    JOURNAL OF CHROMATOGRAPHY, 1980, 182 (3-4): : 285 - 291
  • [5] BA SIMPLE AND RAPID METHOD FOR DETERMINATION OF FLUCONAZOLE IN HUMAN PLASMA SAMPLES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    FLORESMURRIETA, FJ
    GRANADOSSOTO, V
    HONG, E
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1994, 17 (17): : 3803 - 3811
  • [6] RAPID AND SIMPLE METHOD FOR THE ROUTINE DETERMINATION OF DOBUTAMINE IN HUMAN-PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    KNOLL, R
    BRANDL, M
    JOURNAL OF CHROMATOGRAPHY, 1985, 345 (02): : 425 - 429
  • [7] DETERMINATION OF TRICHLORMETHIAZIDE IN HUMAN PLASMA AND URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    SAKATA, T
    MATSUURA, A
    KITAGAWA, T
    CHROMATOGRAPHIA, 1992, 33 (7-8) : 339 - 343
  • [8] DETERMINATION OF PICOTAMIDE IN HUMAN PLASMA AND URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    FOSSATI, T
    PARISI, S
    ABBIATI, G
    CASTIGLIONI, C
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 577 (02): : 382 - 386
  • [9] DETERMINATION OF TENILSETAM IN HUMAN PLASMA AND URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    BURROWS, JL
    COPPIN, FG
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 529 (02): : 486 - 493
  • [10] DETERMINATION OF FAMOTIDINE IN HUMAN PLASMA AND URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    CVITKOVIC, L
    ZUPANCICKRALJ, L
    MARSEL, J
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1991, 9 (02) : 207 - 210