The Minimum Lap-spliced Length of the Reinforcement in the Steam Curing UHPC Bridge Deck Slab Joint

被引:0
作者
Hwang, Hoon-Hee
Park, Sung-Yong
机构
来源
COMPOSITES RESEARCH | 2013年 / 26卷 / 02期
关键词
UHPC; lap-spliced joint; joint; 4 points bending test;
D O I
10.7234/composres.2013.26.2.135
中图分类号
TB33 [复合材料];
学科分类号
摘要
The static test was performed to verify the effect of the joint in the UHPC bridge deck slab and the minimum lap-spliced length was presented. A total of six test members was fabricated to estimate the static behavior of the steam curing UHPC bridge deck slab joint by the four points bending test method. The lap-spliced joint type was expected to be not only simple but also efficient in UHPC structure because of the high bond stress of UHPC. Test results show that the decrease of maximum flexural strength was about 30% and the minimum lap-spliced length which behaved similar to the continued reinforcement in strength and ductility was 150 mm.
引用
收藏
页码:135 / 140
页数:6
相关论文
共 9 条
  • [1] Behaviour of hybrid FRP-UHPC beams subjected to static flexural loading
    El-Hacha, Raafat
    Chen, Donna
    [J]. COMPOSITES PART B-ENGINEERING, 2012, 43 (02) : 582 - 593
  • [2] Graybeal B., 2008, P 2 INT S ULTR PERF, P11
  • [3] Graybeal B. A., 2012, 3 INT S ULTR PERF CO
  • [4] Hwang H, 2011, J KOREAN I STRUCTURA, V15, P92
  • [5] Kim B. S., 2012, 3 INT S ULTR PERF CO
  • [6] Martin S., 2011, CONSTR BUILD MATER, V25, P3078
  • [7] Perry V., 2012, 3 INT S ULTR PERF CO
  • [8] Resplendino, 2008, 2 INT S ULTRA HIGH P, P31
  • [9] Yoo DM, 2011, COMPOS RES, V24, P29