SPIRAL CT WITH 3D-SURFACE DEMONSTRATION FOR THE EVALUATION OF SOLITARY PULMONARY-LESIONS

被引:9
|
作者
STRUNK, H
SCHWEDEN, F
SCHILD, H
THELEN, M
机构
关键词
COMPUTED TOMOGRAPHY; LUNG NEOPLASMS; TECHNIQUE; NEOPLASM; SPIRAL CT; LUNG;
D O I
10.1055/s-2008-1032595
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recently it has been thought possible to characterise a pulmonary lesion by its vascular involvement. The complex vascular relationships are difficult to demonstrate by the ''normal'' technique of transverse CT sections. Spiral CT with 3D-surface reconstruction makes it possible to evaluate the vessels accurately and simulates the appearances one would have by looking into the thorax with a demonstration of all vessels lying within the pulmonary space examined by CT. Venous involvement was shown in every one of 18 malignant lesions but was also found in 4 out of 11 benign lesions, arterial involvement occurred in 14 out of 18 malignant and in 2 benign lesions. CT evidence of vascular involvement is in favour of a malignant tumour but is no absolute proof.
引用
收藏
页码:26 / 30
页数:5
相关论文
共 50 条
  • [31] Solitary Pulmonary Nodule Evaluation by FDG PET/CT
    Exarhos, D. N.
    Skoura, E.
    Keramida, G.
    Tsolaki, S.
    Karampina, P.
    Skilakaki, M.
    Datseris, I. E.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S294 - S294
  • [32] 3-DIMENSIONAL COMPUTED-TOMOGRAPHY IMAGE OF SMALL PULMONARY-LESIONS
    MORI, K
    SAITO, Y
    TOMINAGA, K
    YOKOI, K
    MIYAZAWA, N
    KOUDA, Y
    OKUYAMA, A
    SASAGAWA, M
    MORIYAMA, N
    JAPANESE JOURNAL OF CLINICAL ONCOLOGY, 1992, 22 (03) : 159 - 163
  • [33] 3D-surface parameters and their application on deterministic textured metal sheets
    Pfestorf, M
    Engel, U
    Geiger, M
    INTERNATIONAL JOURNAL OF MACHINE TOOLS & MANUFACTURE, 1998, 38 (5-6): : 607 - 614
  • [34] THE DEVELOPMENT OF PULMONARY-LESIONS ASSOCIATED WITH DEAD ADULT D-IMMITIS IN NAIVE DOGS
    TARISH, JH
    ATWELL, RB
    JOURNAL OF VETERINARY MEDICINE SERIES B-ZENTRALBLATT FUR VETERINARMEDIZIN REIHE B-INFECTIOUS DISEASES AND VETERINARY PUBLIC HEALTH, 1993, 40 (03): : 197 - 205
  • [35] Characterization of solitary pulmonary lesions with PET/CT in Southern California.
    Schiepers, C
    Yap, CS
    Dahlbom, M
    Auerbach, M
    Silverman, DH
    Phelps, ME
    Czernin, J
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S205 - S205
  • [36] Dynamic enhanced multi-slice spiral CT in evaluation of blood flow patterns of solitary pulmonary nodules with enhancement
    LI Shenjiang XIAO Xiangsheng LIU Shiyuan LI Huimin LI Chengzhou ZHANG Chenshi TAO Zhiwei YANG Chunshan Department of Imageology Changzheng Hospital The Second Military Medical University Shanghai PRChina LI Shenjiang now works at Department of Imageology Hospital of PLA Taian Shangdong Province
    中国肺癌杂志, 2004, (06) : 520 - 525
  • [37] CEREBRAL ANEURYSMS - 3-DIMENSIONAL DEMONSTRATION WITH SPIRAL CT
    RIEGER, J
    HOSTEN, N
    LEMKE, AJ
    LANGER, R
    LANKSCH, WR
    FELIX, R
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1994, 160 (03): : 204 - 209
  • [38] Role of spiral multidetector CT (MDCT) in evaluation of pancreatic lesions
    Sawalakhe, N.
    Veenu, P.
    Nistala, S.
    Sasidharan, M.
    Rathi, P. M.
    Shetty, D. S.
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2008, 23 : A139 - A139
  • [39] SPIRAL CT IN EVALUATION OF HEAD AND NECK LESIONS - WORK IN PROGRESS
    SUOJANEN, JN
    MUKHERJI, SK
    DUPUY, DE
    TAKAHASHI, JH
    COSTELLO, P
    RADIOLOGY, 1992, 183 (01) : 281 - 283
  • [40] 3D IMAGING WITH SPIRAL CT - EXPERIMENTAL EVALUATION OF OBJECT DISTORTION
    PROKOP, M
    SCHAEFER, CM
    GALANSKI, M
    NISCHELSKY, JE
    REIMER, P
    LEPPERT, A
    RADIOLOGY, 1992, 185 : 127 - 127