Simulating Performance Risk for Lighting Retrofit Decisions

被引:4
作者
Hu, Jia [1 ]
Shen, Eric [1 ]
Gu, Yun [1 ]
机构
[1] Philips Res North Amer, Briarcliff Manor, NY 10510 USA
来源
BUILDINGS | 2015年 / 5卷 / 02期
关键词
risk; lighting; retrofit; simulation; EnergyPlus; surrogate model;
D O I
10.3390/buildings5020650
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In building retrofit projects, dynamic simulations are performed to simulate building performance. Uncertainty may negatively affect model calibration and predicted lighting energy savings, which increases the chance of default on performance-based contracts. Therefore, the aim of this paper is to develop a simulation-based method that can analyze lighting performance risk in lighting retrofit decisions. The model uses a surrogate model, which is constructed by adaptively selecting sample points and generating approximation surfaces with fast computing time. The surrogate model is a replacement of the computation intensive process. A statistical method is developed to generate extreme weather profile based on the 20-year historical weather data. A stochastic occupancy model was created using actual occupancy data to generate realistic occupancy patterns. Energy usage of lighting, and heating, ventilation, and air conditioning (HVAC) is simulated using EnergyPlus. The method can evaluate the influence of different risk factors (e.g., variation of luminaire input wattage, varying weather conditions) on lighting and HVAC energy consumption and lighting electricity demand. Probability distributions are generated to quantify the risk values. A case study was conducted to demonstrate and validate the methods. The surrogate model is a good solution for quantifying the risk factors and probability distribution of the building performance.
引用
收藏
页码:650 / 667
页数:18
相关论文
共 23 条
  • [1] American Society of Heating Refrigerating and Air Conditioning Inc (ASHREA), 1989, 9011989 ANSIASHRAEIE
  • [2] Multi-objective optimization for building retrofit strategies: A model and an application
    Asadi, Ehsan
    da Silva, Manuel Gameiro
    Antunes, Carlos Henggeler
    Dias, Luis
    [J]. ENERGY AND BUILDINGS, 2012, 44 : 81 - 87
  • [3] A method for generation of typical meteorological year
    Ebrahimpour, Abdulsalam
    Maerefat, Mehdi
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2010, 51 (03) : 410 - 417
  • [4] Uncertainty and sensitivity decomposition of building energy models
    Eisenhower, Bryan
    O'Neill, Zheng
    Fonoberov, Vladimir A.
    Mezic, Igor
    [J]. JOURNAL OF BUILDING PERFORMANCE SIMULATION, 2012, 5 (03) : 171 - 184
  • [5] Recent advances in surrogate-based optimization
    Forrester, Alexander I. J.
    Keane, Andy J.
    [J]. PROGRESS IN AEROSPACE SCIENCES, 2009, 45 (1-3) : 50 - 79
  • [6] An interactive expert system for daylighting design exploration
    Gagne, Jaime M. L.
    Andersen, Marilyne
    Norford, Leslie K.
    [J]. BUILDING AND ENVIRONMENT, 2011, 46 (11) : 2351 - 2364
  • [7] Calibration of building energy models for retrofit analysis under uncertainty
    Heo, Y.
    Choudhary, R.
    Augenbroe, G. A.
    [J]. ENERGY AND BUILDINGS, 2012, 47 : 550 - 560
  • [8] Comparison between detailed model simulation and artificial neural network for forecasting building energy consumption
    Hernandez Neto, Alberto
    Sanzovo Fiorelli, Flavio Augusto
    [J]. ENERGY AND BUILDINGS, 2008, 40 (12) : 2169 - 2176
  • [9] Hu J., 2012, P ASCE 2012 INT C CO
  • [10] Simulation-Based Model for Integrated Daylighting System Design
    Hu, Jia
    Olbina, Svetlana
    [J]. JOURNAL OF COMPUTING IN CIVIL ENGINEERING, 2014, 28 (05)