Determination of radiation absorbed dose to primary liver tumors and normal liver tissue using post-radioembolization Y-90 PET

被引:56
作者
Srinivas, Shyam M. [1 ]
Natarajan, Navin [2 ]
Kuroiwa, Joshua [3 ]
Gallagher, Sean [3 ]
Nasr, Elie [1 ]
Shah, Shetal N. [1 ]
DiFilippo, Frank P. [1 ]
Obuchowski, Nancy [4 ]
Bazerbashi, Bana [5 ]
Yu, Naichang [6 ]
McLennan, Gordon [5 ]
机构
[1] Cleveland Clin, Dept Nucl Med, Cleveland, OH 44106 USA
[2] Case Western Reserve Univ, Sch Med, Cleveland, OH USA
[3] Ohio Univ, Heritage Coll Osteopath Med, Athens, OH 45701 USA
[4] Cleveland Clin, Dept Quantitat Hlth Sci, Cleveland, OH 44106 USA
[5] Cleveland Clin, Sect Vasc & Intervent Radiol, Cleveland, OH 44106 USA
[6] Cleveland Clin, Dept Radiat Oncol, Cleveland, OH 44106 USA
来源
FRONTIERS IN ONCOLOGY | 2014年 / 4卷
关键词
Yttrium-90; radioembolization; HCC; Y-90; PET/CT; dosimetry; response;
D O I
10.3389/fonc.2014.00255
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Radioembolization with Yttrium-90 (Y-90) microspheres is becoming a more widely used transcatheter treatment for unresectable hepatocellular carcinoma (HCC). Using post-treatment Y-90 positron emission tomography/computerized tomography (PET/CT) scans, the distribution of microspheres within the liver can be determined and quantitatively assessed. We studied the radiation dose of Y-90 delivered to liver and treated tumors. Methods: This retrospective study of 56 patients with HCC, including analysis of 98 liver tumors, measured and correlated the dose of radiation delivered to liver tumors and normal liver tissue using glass microspheres (TheraSpheres (R) to the frequency of complications with modified response evaluation criteria in solid tumors (mRECIST). 90Y PET/CT and triphasic liver CT scans were used to contour treated tumor and normal liver regions and determine their respective activity concentrations. An absorbed dose factor was used to convert the measured activity concentration (Bq/mL) to an absorbed dose (Gy). Results: The 98 studied tumors received a mean dose of 169 Gy (mode 90-120 Gy; range 0-570 Gy). Tumor response by mRECIST criteria was performed for 48 tumors that had follow-up scans. There were 21 responders (mean dose 215 Gy) and 27 non-responders (mean dose 167 Gy). The association between mean tumor absorbed dose and response suggests a trend but did not reach statistical significance (p=0.099). Normal liver tissue received a mean dose of 67 Gy (mode 60-70 Gy; range 10-120 Gy).There was a statistically significant association between absorbed dose to normal liver and the presence of two or more severe complications (p = 0.036). Conclusion: Our cohort of patients showed a possible dose response trend for the tumors. Collateral dose to normal liver is non-trivial and can have clinical implications. These methods help us understand whether patient adverse events, treatment success, or treatment failure can be attributed to the dose that the tumor or normal liver received.
引用
收藏
页数:12
相关论文
共 29 条
  • [1] Radioembolization for Hepatocellular Carcinoma using TheraSphere®
    Ali, Safiyya Mohamed
    [J]. SAUDI JOURNAL OF GASTROENTEROLOGY, 2011, 17 (03) : 215 - 217
  • [3] Axelrod D. A., HEPATOCELLULAR CARCI
  • [4] Intraprocedural Yttrium-90 Positron Emission Tomography/CT for Treatment Optimization of Yttrium-90 Radioembolization
    Bourgeois, Austin C.
    Chang, Ted T.
    Bradley, Yong C.
    Acuff, Shelley N.
    Pasciak, Alexander S.
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2014, 25 (02) : 271 - 275
  • [5] Treatment Modification of Yttrium-90 Radioembolization Based on Quantitative Positron Emission Tomography/CT Imaging
    Chang, Ted T.
    Bourgeois, Austin C.
    Balius, Anastasia M.
    Pasciak, Alexander S.
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2013, 24 (03) : 333 - 337
  • [6] Chiesa C, 2012, Q J NUCL MED MOL IM, V56, P503
  • [7] 90Y PET-based dosimetry after selective internal radiotherapy treatments
    D'Arienzo, Marco
    Chiaramida, Paola
    Chiacchiararelli, Laura
    Coniglio, Angela
    Cianni, Roberto
    Salvatori, Rita
    Ruzza, Alberto
    Scopinaro, Francesco
    Bagni, Oreste
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 2012, 33 (06) : 633 - 640
  • [8] Recommendations of the American Association of Physicists in Medicine on dosimetry, imaging, and quality assurance procedures for 90Y microsphere brachytherapy in the treatment of hepatic malignancies
    Dezarn, William A.
    Cessna, Jeffery T.
    DeWerd, Larry A.
    Feng, Wenzheng
    Gates, Vanessa L.
    Halama, James
    Kennedy, Andrew S.
    Nag, Subir
    Sarfaraz, Mehrdad
    Sehgal, Varun
    Selwyn, Reed
    Stabin, Michael G.
    Thomadsen, Bruce R.
    Williams, Lawrence E.
    Salem, Riad
    [J]. MEDICAL PHYSICS, 2011, 38 (08) : 4824 - 4845
  • [9] Quantitative Monte Carlo-Based 90Y SPECT Reconstruction
    Elschot, Mattijs
    Lam, Marnix G. E. H.
    van den Bosch, Maurice A. A. J.
    Viergever, Max A.
    de Jong, Hugo W. A. M.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2013, 54 (09) : 1557 - 1563
  • [10] Hepatocellular carcinoma
    Forner, Alejandro
    Llovet, Josep M.
    Bruix, Jordi
    [J]. LANCET, 2012, 379 (9822) : 1245 - 1255