Cardiac Output Monitoring: Is There a Gold Standard and How Do the Newer Technologies Compare?

被引:65
作者
Pugsley, Jacob [1 ]
Lerner, Adam B. [1 ]
机构
[1] Beth Israel Deaconess Med Ctr, 1 Deaconess Rd, Boston, MA 02215 USA
关键词
monitoring; cardiac output measurement; gold standard; Fick; thermodilution; pulse contour analysis; TEE; NICO;
D O I
10.1177/1089253210386386
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
As a principal determinant of oxygen delivery and of blood pressure, cardiac output (CO) represents an important hemodynamic variable. Its accurate measurement, therefore, is important to the clinician caring for critically ill patients in a variety of care environments. Though the first clinical measurement of CO occurred 70 years ago, it was the introduction of the pulmonary artery catheter (PAC) with thermodilution-based determination of CO in the 1970s that set the stage for practical and widespread clinical measurement of CO. Although the usefulness and accuracy of this technique have justified its consideration as a "practical" gold standard in CO measurement, its drawbacks have driven the search for newer, less invasive measurement techniques. The last decade has seen the introduction of several such devices into the clinical arena. This article will serve to give a brief review of the history of CO measurement, to provide a discussion of the measurement of accuracy as it relates to CO measurement, and to discuss some of the newer methods and devices for CO measurement and how they have fared against a "practical" gold standard.
引用
收藏
页码:274 / 282
页数:9
相关论文
共 91 条
  • [31] Cardiac output measurements in off-pump coronary surgery: comparison between NICO and the Swan-Ganz catheter
    Gueret, G.
    Rossignol, B.
    Kiss, G.
    Bezon, E.
    Wargnier, J. P.
    Miossec, A.
    Corre, O.
    Arvieux, C. C.
    [J]. EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2006, 23 (10) : 848 - 854
  • [32] Continuous cardiac output during off-pump coronary artery bypass surgery:: pulse-contour analyses vs pulmonary artery thermodilution
    Halvorsen, P. S.
    Sokolovl, A.
    Cvancarova, M.
    Hol, P. K.
    Lundblad, R.
    Tonnessen, T. I.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2007, 99 (04) : 484 - 492
  • [33] Agreement between PiCCO pulse-contour analysis, pulmonal artery thermodilution and transthoracic thermodilution during off-pump coronary artery by-pass surgery
    Halvorsen, P. S.
    Espinoza, A.
    Lundblad, R.
    Cvancarova, M.
    Hol, P. K.
    Fosse, E.
    Tonnessen, T. I.
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2006, 50 (09) : 1050 - 1057
  • [34] Hamilton TT, 2002, ANN THORAC SURG, V74, pS1408
  • [35] REPRODUCIBILITY OF QUANTITATIVE TWO-DIMENSIONAL ECHOCARDIOGRAPHY
    HIMELMAN, RB
    CASSIDY, MM
    LANDZBERG, JS
    SCHILLER, NB
    [J]. AMERICAN HEART JOURNAL, 1988, 115 (02) : 425 - 431
  • [36] Partial CO2 rebreathing cardiac output -: Operating principles of the NICO™ system
    Jaffe, MB
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (06) : 387 - 401
  • [37] Goal-directed Perioperative Fluid Management Why, When, and How?
    Kehlet, Henrik
    Bundgaard-Nielsen, Morten
    [J]. ANESTHESIOLOGY, 2009, 110 (03) : 453 - 455
  • [38] Evaluation of two methods for continuous cardiac output assessment during exercise in chronic heart failure patients
    Kemps, Hareld M. C.
    Thijssen, Eric J. M.
    Schep, Goof
    Sleutjes, Boudewijn T. H. M.
    De Vries, Wouter R.
    Hoogeveen, Adwin R.
    Wijn, Pieter F. F.
    Doevendans, Pieter A. F. M.
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 2008, 105 (06) : 1822 - 1829
  • [39] DIRECT FICK CARDIAC-OUTPUT - ARE ASSUMED VALUES OF OXYGEN-CONSUMPTION ACCEPTABLE
    KENDRICK, AH
    WEST, J
    PAPOUCHADO, M
    ROZKOVEC, A
    [J]. EUROPEAN HEART JOURNAL, 1988, 9 (03) : 337 - 342
  • [40] Arterial pulse wave analysis: An accurate means of determining cardiac output in children
    Kim, Jeffrey J.
    Dreyer, Jeffrey
    Chang, Anthony C.
    Breinholt, John P., III
    Grifka, Ronald G.
    [J]. PEDIATRIC CRITICAL CARE MEDICINE, 2006, 7 (06) : 532 - 535