X-RAY MONITOR ON INTEGRAL - ASTROPHYSICS IN THE 4-100 KEV BAND

被引:0
|
作者
UBERTINI, P
机构
来源
ASTRONOMY & ASTROPHYSICS SUPPLEMENT SERIES | 1993年 / 97卷 / 01期
关键词
ARTIFICIAL SATELLITES; INSTRUMENTATION; DETECTORS; GAMMA-RAYS; OBSERVATIONS; X-RAY; GENERAL;
D O I
暂无
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
The X-Ray Monitor on INTREGAL will provide images with arcminute angular resolution in the 4-100 keV band, simultaneously with the main gamma ray instruments. The limiting sensitivity for a typical 10(5) second observation will be better than one millicrab. The baseline photon detection system is a high pressure imaging proportional counter behind a coded mask (focal length 4 meters; FOV 6 degrees FWHM to match the other instruments). In addition to its support role on INTEGRAL (providing fine imaging and simultaneous X-Ray flux measurements) the spectral resolution and sensitivity are sufficient to make it a useful stand-alone instrument. In particular it will be able to monitor the iron lines seen in both Galactic and extra-Galactic sources, and relate these to the behavior of the hard continuum, seen in the other instruments. It will also enable the study of hard X-Ray continua of many Galactic and extra-Galactic sources: specifically the search for cyclotron lines in Galactic binaries, Compton 'humps', and other features in AGN spectra, perhaps evidence for pair processes. Because of its high sensitivity it will be used to scan the Galactic plane once every few days to detect the onset of transients (potential 'hard tail' objects), which can then be observed in detail by the Gamma ray instruments.
引用
收藏
页码:389 / 392
页数:4
相关论文
共 50 条
  • [31] Innovative X-ray optics for astrophysics
    Inneman, A
    Pina, L
    Hudec, R
    Ticha, H
    Brozek, V
    DESIGN AND MICROFABRICATION OF NOVEL X-RAY OPTICS, 2002, 4783 : 156 - 164
  • [32] Uncooled spectrometer for X-ray astrophysics
    Urban, Martin
    Nentvich, Ondrej
    Stehlikova, Veronika
    Sieger, Ladislav
    EUV AND X-RAY OPTICS: SYNERGY BETWEEN LABORATORY AND SPACE V, 2017, 10235
  • [33] ASTROPHYSICS Unexpected X-ray flares
    Campana, Sergio
    NATURE, 2016, 538 (7625) : 321 - 322
  • [34] X-ray Diffraction Gratings for Astrophysics
    Paerels, Frits
    SPACE SCIENCE REVIEWS, 2010, 157 (1-4) : 15 - 24
  • [35] Atomic data for x-ray astrophysics
    Kallman, T. R.
    Palmeri, P.
    REVIEWS OF MODERN PHYSICS, 2007, 79 (01) : 79 - 133
  • [36] In-flight calibration system for the INTEGRAL X-ray monitor JEM-X
    Costa, E
    Feroci, M
    Barbanera, L
    Frutti, M
    Rubini, A
    BudtzJorgensen, C
    Schnopper, HW
    GAMMA-RAY AND COSMIC-RAY DETECTORS, TECHNIQUES, AND MISSIONS, 1996, 2806 : 502 - 508
  • [37] Origins of the 1/4 keV soft X-ray background
    Bellm, EC
    Vaillancourt, JE
    ASTROPHYSICAL JOURNAL, 2005, 622 (02): : 959 - 964
  • [38] Limits to the 1/4 keV extragalactic X-ray background
    Cui, W
    Sanders, WT
    McCammon, D
    Snowden, SL
    Womble, DS
    ASTROPHYSICAL JOURNAL, 1996, 468 (01): : 117 - 120
  • [39] W/SiC x-ray multilayers optimized for use above 100 keV
    Windt, DL
    Donguy, S
    Hailey, CJ
    Koglin, J
    Honkimaki, V
    Ziegler, E
    Christensen, FE
    Chen, H
    Harrison, FA
    Craig, WW
    APPLIED OPTICS, 2003, 42 (13) : 2415 - 2421
  • [40] X-RAY SENSITIVITY OF NO-SCREEN FILM IN 1 TO 100 KEV REGION
    DOZIER, CM
    BROWN, DB
    BIRKS, LS
    LYONS, PB
    BENJAMIN, RF
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1976, 21 (04): : 596 - 597