X-RAY MONITOR ON INTEGRAL - ASTROPHYSICS IN THE 4-100 KEV BAND

被引:0
|
作者
UBERTINI, P
机构
来源
ASTRONOMY & ASTROPHYSICS SUPPLEMENT SERIES | 1993年 / 97卷 / 01期
关键词
ARTIFICIAL SATELLITES; INSTRUMENTATION; DETECTORS; GAMMA-RAYS; OBSERVATIONS; X-RAY; GENERAL;
D O I
暂无
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
The X-Ray Monitor on INTREGAL will provide images with arcminute angular resolution in the 4-100 keV band, simultaneously with the main gamma ray instruments. The limiting sensitivity for a typical 10(5) second observation will be better than one millicrab. The baseline photon detection system is a high pressure imaging proportional counter behind a coded mask (focal length 4 meters; FOV 6 degrees FWHM to match the other instruments). In addition to its support role on INTEGRAL (providing fine imaging and simultaneous X-Ray flux measurements) the spectral resolution and sensitivity are sufficient to make it a useful stand-alone instrument. In particular it will be able to monitor the iron lines seen in both Galactic and extra-Galactic sources, and relate these to the behavior of the hard continuum, seen in the other instruments. It will also enable the study of hard X-Ray continua of many Galactic and extra-Galactic sources: specifically the search for cyclotron lines in Galactic binaries, Compton 'humps', and other features in AGN spectra, perhaps evidence for pair processes. Because of its high sensitivity it will be used to scan the Galactic plane once every few days to detect the onset of transients (potential 'hard tail' objects), which can then be observed in detail by the Gamma ray instruments.
引用
收藏
页码:389 / 392
页数:4
相关论文
共 50 条
  • [21] 1/4 KEV X-RAY BACKGROUND - REPLY
    BROWN, RL
    NATURE-PHYSICAL SCIENCE, 1971, 229 (03): : 85 - &
  • [22] THE STANDARDIZATION OF X-RAY SOURCES BELOW 4 KEV
    KACPEREK, A
    DENECKE, B
    REHER, D
    BAMBYNEK, W
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 192 (01): : 109 - 115
  • [23] ASTRONOMY AND ASTROPHYSICS WITH THE ADVANCED X-RAY ASTROPHYSICS FACILITY
    WEISSKOPF, MC
    SPACE SCIENCE REVIEWS, 1988, 47 (1-2) : 47 - 93
  • [24] Preliminary background prediction for the INTEGRAL X-ray monitor JEM-X
    Feroci, M
    Costa, E
    BudtzJorgensen, C
    Schnopper, HW
    Westergaard, NJ
    Rapisarda, M
    GAMMA-RAY AND COSMIC-RAY DETECTORS, TECHNIQUES, AND MISSIONS, 1996, 2806 : 494 - 501
  • [25] Earth X-ray albedo for cosmic X-ray background radiation in the 1-1000 keV band
    Churazov, E.
    Sazonov, S.
    Sunyaev, R.
    Revnivtsev, M.
    MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, 2008, 385 (02) : 719 - 727
  • [26] X-ray multilayer coatings for use at energies above 100 keV
    Windt, DL
    Christensen, F
    Craig, W
    Hailey, C
    Harrison, F
    Jimenez-Garate, M
    Kalyanaraman, R
    Mao, P
    X-RAY OPTICS, INSTRUMENTS, AND MISSIONS III, 2000, 4012 : 442 - 447
  • [27] CdZnTe x-ray detector for 30 similar to 100 keV energy
    Yoo, SS
    Rodricks, B
    Shastri, SD
    Montano, PA
    HARD X-RAY/GAMMA-RAY AND NEUTRON OPTICS, SENSORS, AND APPLICATIONS, 1996, 2859 : 50 - 56
  • [28] X-ray Diffraction Gratings for Astrophysics
    Frits Paerels
    Space Science Reviews, 2010, 157 : 15 - 24
  • [29] Astrophysics of X-Ray Binary Spectra
    Leticia C.B.
    Defect and Diffusion Forum, 2023, 429 : 45 - 70
  • [30] THE ADVANCED X-RAY ASTROPHYSICS FACILITY
    TANANBAUM, H