Electrochemical sensors have seen extensive development in recent years, particularly with regard to their use in biological fluids. Their facility for near-reagentless assay, together with an ability to generate a continuous signal, has made them an ideal choice for in vivo monitoring. Both amperometric and potentiometric devices have been fabricated for practical monitoring. Ions, gases, and metabolites have been assayed, thereby providing useful biological and clinical insights. This view provides a description of the major types of electrochemical sensors used in vivo, together with some of the problems associated with their biological interfacing for both extracorporeal and invasive monitoring.
引用
收藏
页码:597 / 606
页数:10
相关论文
共 60 条
[51]  
TANG LX, 1989, MED BIOL ENG COMPUT, V28, pB18
[52]   CATHETER-TIP POTASSIUM-SELECTIVE ELECTRODE [J].
TREASURE, T ;
BAND, DM .
JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1977, 1 (05) :271-273
[53]  
VANDERKLEIJ AJ, 1983, SURGERY, V93, P518
[54]   USE OF AN ARTERIAL PH CATHETER IMMEDIATELY AFTER CORONARY-ARTERY BYPASS-GRAFTING [J].
VANDERSTARRE, PJA ;
HARINCKDEWEERD, JE ;
SCHEPEL, SJ ;
KOOTSTRA, GJ .
CRITICAL CARE MEDICINE, 1986, 14 (09) :812-814
[55]   INVITRO AND INVIVO STABILITY OF ELECTRODE-POTENTIALS IN NEEDLE-TYPE GLUCOSE SENSORS - INFLUENCE OF NEEDLE MATERIAL [J].
VELHO, G ;
FROGUEL, P ;
STERNBERG, R ;
THEVENOT, DR ;
REACH, G .
DIABETES, 1989, 38 (02) :164-171
[56]   LONG VOLTAMMETRIC MICROELECTRODE FOR INVIVO MONITORING OF ACETAMINOPHEN IN PRIMATE SPECIES [J].
WANG, J ;
HUTCHINS, LD ;
SELIM, S ;
CUMMINS, LB .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1984, 12 (3-4) :193-203
[57]   DETECTION OF DOPAMINE DYNAMICS IN THE BRAIN [J].
WIGHTMAN, RM ;
MAY, LJ ;
MICHAEL, AC .
ANALYTICAL CHEMISTRY, 1988, 60 (13) :A769-&
[58]   REAL-TIME CHARACTERIZATION OF DOPAMINE OVERFLOW AND UPTAKE IN THE RAT STRIATUM [J].
WIGHTMAN, RM ;
AMATORE, C ;
ENGSTROM, RC ;
HALE, PD ;
KRISTENSEN, EW ;
KUHR, WG ;
MAY, LJ .
NEUROSCIENCE, 1988, 25 (02) :513-523
[59]  
WILKINS ES, 1988, HORM METAB RES, V20, P50
[60]   HOW FIBROBLASTS AND GIANT-CELLS ENCAPSULATE IMPLANTS - CONSIDERATIONS IN DESIGN OF GLUCOSE SENSORS [J].
WOODWARD, SC .
DIABETES CARE, 1982, 5 (03) :278-281