Evaluation of an iterative model-based reconstruction algorithm for low-tube-voltage (80 kVp) computed tomography angiography

被引:21
作者
Noel, Peter B. [1 ]
Koehler, Thomas [2 ]
Fingerle, Alexander A. [1 ]
Brown, Kevin M. [3 ]
Zabic, Stanislav [3 ]
Muenzel, Daniela [1 ]
Haller, Bernhard [4 ]
Baum, Thomas [1 ]
Henninger, Martin [1 ]
Meier, Reinhard [1 ]
Rummeny, Ernst J. [1 ]
Dobritz, Martin [1 ]
机构
[1] Tech Univ Munich, Dept Radiol, D-81675 Munich, Germany
[2] Philips Res Labs, D-22335 Hamburg, Germany
[3] Philips Healthcare, Cleveland, OH 44143 USA
[4] Tech Univ Munich, Inst Med Stat & Epidemiol, D-81675 Munich, Germany
关键词
computed tomography; iterative reconstruction; low-tube-current; computed tomography angiography; dose reduction; low-tube-voltage;
D O I
10.1117/1.JMI.1.3.033501
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The objective of this study was to investigate the improvement in diagnostic quality of an iterative model-based reconstruction (IMBR) algorithm for low-tube-voltage (80-kVp) and low-tube-current in abdominal computed tomography angiography (CTA). A total of 11 patients were imaged on a 256-slice multidetector computed tomography for visualization of the aorta. For all patients, three different reconstructions from the low-tube-voltage data are generated: filtered backprojection (FBP), IMBR, and a mixture of both IMBR + FBP. To determine the diagnostic value of IMBR-based reconstructions, the image quality was assessed. With IMBRbased reconstructions, image noise could be significantly reduced, which was confirmed by a highly improved contrast-to-noise ratio. In the image quality assessment, radiologists were able to reliably detect more third-order and higher aortic branches in the IMBR reconstructions compared to FBP reconstructions. The effective dose level was, on average, 3.0 mSv for 80-kVp acquisitions. Low-tube-voltage CTAs significantly improve vascular contrast as presented by others; however, this effect in combination with IMBR enabled yet another substantial improvement of diagnostic quality. For IMBR, a significant improvement of image quality and a decreased radiation dose at low-tube-voltage can be reported. (C) The Authors. Published by SPIE under a Creative Commons Attribution 3.0 Unported License.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Dynamic Computed Tomography of Locally Advanced Pancreatic Cancer: Effect of Low Tube Voltage and a Hybrid Iterative Reconstruction Algorithm on Image Quality
    Yamamura, Sadahiro
    Oda, Seitaro
    Utsunomiya, Daisuke
    Funama, Yoshinori
    Imuta, Masanori
    Namimoto, Tomohiro
    Hirai, Toshinori
    Chikamoto, Akira
    Baba, Hideo
    Yamashita, Yasuyuki
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (05) : 790 - 796
  • [22] A comparative study of low voltage, low contrast cerebral computed tomography angiography with iterative reconstruction and conventional cerebral computed tomography angiography
    Mishra, Saurav
    Mishra, Sandeep
    Regmi, Sabina
    Gupta, Vivek
    NEURORADIOLOGY JOURNAL, 2024, 37 (02) : 221 - 228
  • [23] Submillisievert Computed Tomography of the Chest Using Model-Based Iterative Algorithm: Optimization of Tube Voltage With Regard to Patient Size
    Deak, Zsuzsanna
    Maertz, Friedrich
    Meurer, Felix
    Notohamiprodjo, Susan
    Mueck, Fabian
    Geyer, Lucas L.
    Reiser, Maximilian F.
    Wirth, Stefan
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2017, 41 (02) : 254 - 262
  • [24] Model-based Iterative Reconstruction: A Promising Algorithm for Today's Computed Tomography Imaging
    Liu, Lu
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2014, 45 (02) : 131 - 136
  • [25] Computed tomography depiction of small pediatric vessels with model-based iterative reconstruction
    Koc, Gonca
    Courtier, Jesse L.
    Phelps, Andrew
    Marcovici, Peter A.
    MacKenzie, John D.
    PEDIATRIC RADIOLOGY, 2014, 44 (07) : 787 - 794
  • [26] Application of 80-kVp tube voltage, low-concentration contrast agent and iterative reconstruction in coronary CT angiography: evaluation of image quality and radiation dose
    Wu, Qiyong
    Wang, Yong
    Kai, Huihua
    Wang, Tao
    Tang, Xiaoqiang
    Wang, Xiaoqin
    Pan, Changjie
    INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2016, 70 (9B) : B50 - B55
  • [27] Non-enhanced Low-tube-voltage High-pitch Dual-source Computed Tomography with Sinogram Affirmed Iterative Reconstruction Algorithm of the Abdomen and Pelvis
    Hao Sun
    Hua-dan Xue
    Zheng-yu Jin
    Xuan Wang
    Yu Chen
    Yong-lan He
    Da-ming Zhang
    Liang Zhu
    Chinese Medical Sciences Journal, 2014, 29 (04) : 214 - 220
  • [28] Low-tube-voltage (80 kVp) CT aortography using 320-row volume CT with adaptive iterative reconstruction: lower contrast medium and radiation dose
    Chen, Chien-Ming
    Chu, Sung-Yu
    Hsu, Ming-Yi
    Liao, Ying-Lan
    Tsai, Hui-Yu
    EUROPEAN RADIOLOGY, 2014, 24 (02) : 460 - 468
  • [29] Three-Dimensional Computed Tomographic Angiography of the Liver for Planning Hepatic Surgery: Effect of Low Tube Voltage and the Iterative Reconstruction Algorithm on Image Quality
    Honda, Keiichi
    Oda, Seitaro
    Katahira, Kazuhiro
    Kajihara, Hiroo
    Morishita, Shoji
    Honbori, Maki
    Kawata, Kenji
    Nasu, Jiro
    Utsunomiya, Daisuke
    Funama, Yoshinori
    Yamashita, Yasuyuki
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2014, 38 (01) : 131 - 136
  • [30] Diagnostic accuracy of low-radiation coronary computed tomography angiography with low tube voltage and knowledge-based model reconstruction
    Lee, Joohee
    Kim, Tae Hoon
    Lee, Byoung Kwon
    Yoon, Young Won
    Kwon, Hyuck Moon
    Hong, Bum Kee
    Min, Pil-Ki
    Choi, Eui-Young
    Oh, Chi Suk
    Park, Chul Hwan
    SCIENTIFIC REPORTS, 2019, 9 (1)