Evaluation of an iterative model-based reconstruction algorithm for low-tube-voltage (80 kVp) computed tomography angiography

被引:21
作者
Noel, Peter B. [1 ]
Koehler, Thomas [2 ]
Fingerle, Alexander A. [1 ]
Brown, Kevin M. [3 ]
Zabic, Stanislav [3 ]
Muenzel, Daniela [1 ]
Haller, Bernhard [4 ]
Baum, Thomas [1 ]
Henninger, Martin [1 ]
Meier, Reinhard [1 ]
Rummeny, Ernst J. [1 ]
Dobritz, Martin [1 ]
机构
[1] Tech Univ Munich, Dept Radiol, D-81675 Munich, Germany
[2] Philips Res Labs, D-22335 Hamburg, Germany
[3] Philips Healthcare, Cleveland, OH 44143 USA
[4] Tech Univ Munich, Inst Med Stat & Epidemiol, D-81675 Munich, Germany
关键词
computed tomography; iterative reconstruction; low-tube-current; computed tomography angiography; dose reduction; low-tube-voltage;
D O I
10.1117/1.JMI.1.3.033501
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The objective of this study was to investigate the improvement in diagnostic quality of an iterative model-based reconstruction (IMBR) algorithm for low-tube-voltage (80-kVp) and low-tube-current in abdominal computed tomography angiography (CTA). A total of 11 patients were imaged on a 256-slice multidetector computed tomography for visualization of the aorta. For all patients, three different reconstructions from the low-tube-voltage data are generated: filtered backprojection (FBP), IMBR, and a mixture of both IMBR + FBP. To determine the diagnostic value of IMBR-based reconstructions, the image quality was assessed. With IMBRbased reconstructions, image noise could be significantly reduced, which was confirmed by a highly improved contrast-to-noise ratio. In the image quality assessment, radiologists were able to reliably detect more third-order and higher aortic branches in the IMBR reconstructions compared to FBP reconstructions. The effective dose level was, on average, 3.0 mSv for 80-kVp acquisitions. Low-tube-voltage CTAs significantly improve vascular contrast as presented by others; however, this effect in combination with IMBR enabled yet another substantial improvement of diagnostic quality. For IMBR, a significant improvement of image quality and a decreased radiation dose at low-tube-voltage can be reported. (C) The Authors. Published by SPIE under a Creative Commons Attribution 3.0 Unported License.
引用
收藏
页数:7
相关论文
共 24 条
[21]   A three-dimensional statistical approach to improved image quality for multislice helical CT [J].
Thibault, Jean-Baptiste ;
Sauer, Ken D. ;
Bouman, Charles A. ;
Hsieh, Jiang .
MEDICAL PHYSICS, 2007, 34 (11) :4526-4544
[22]   Circle of Willis at CT angiography: Dose reduction and image quality - reducing tube voltage and increasing tube current settings [J].
Waaijer, Annet ;
Prokop, Mathias ;
Velthuis, Birgitta K. ;
Bakker, Chris J. G. ;
de Kort, Gerard A. P. ;
van Leeuwen, Maarten S. .
RADIOLOGY, 2007, 242 (03) :832-839
[23]   Raw data-based iterative reconstruction in body CTA: evaluation of radiation dose saving potential [J].
Winklehner, Anna ;
Karlo, Christoph ;
Puippe, Gilbert ;
Schmidt, Bernhard ;
Flohr, Thomas ;
Goetti, Robert ;
Pfammatter, Thomas ;
Frauenfelder, Thomas ;
Alkadhi, Hatem .
EUROPEAN RADIOLOGY, 2011, 21 (12) :2521-2526
[24]   Aorto-iliac multidetector-row CT angiography with low kV settings: improved vessel enhancement and simultaneous reduction of radiation dose [J].
Wintersperger, B ;
Jacobs, T ;
Herzog, P ;
Schaller, S ;
Nikolaou, K ;
Suess, C ;
Weber, C ;
Reiser, M ;
Becker, C .
EUROPEAN RADIOLOGY, 2005, 15 (02) :334-341