A MODEL FOR ELECTRON-BEAM APPLICATOR SCATTER

被引:29
作者
EBERT, MA [1 ]
HOBAN, PW [1 ]
机构
[1] ROYAL ADELAIDE HOSP,DEPT MED PHYS,ADELAIDE,SA 5000,AUSTRALIA
关键词
ELECTRON BEAMS; APPLICATORS; MONTE CARLO;
D O I
10.1118/1.597415
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Applicators (or cones), used in conjunction with patient specific cutouts in electron-beam radiotherapy, may interact with the primary electron beam to produce a secondary beam component (applicator scatter). This component affects machine output as well as the shape of resulting dose distributions. A model has been developed to simulate this scatter component for applicators consisting of trimming plates of arbitrary shape. This model involves sampling established kernels of scatter from edge elements of appropriate materials, obtained through Monte Carlo simulations. The result of the model is a phase space (position, direction, energy, charge, weighting) of applicator scattered particles which can be incorporated into a further Monte Carlo simulation, or as input into another advanced treatment planning algorithm. This model is evaluated by comparison of measured profiles and applicator scatter component depth dose curves with Monte Carlo simulations using simulated phase-space data as input. Results are very consistent and reveal information on the angular and spatial variation characteristics of this beam component. The results obtained verify the developed model as an accurate predictor of the characteristics of applicator scattered particles.
引用
收藏
页码:1419 / 1429
页数:11
相关论文
共 23 条
  • [1] [Anonymous], [No title captured]
  • [2] ELECTRON DOSIMETRY OF IRREGULAR FIELDS ON THE CLINAC-18
    BIGGS, PJ
    BOYER, AL
    DOPPKE, KP
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1979, 5 (03): : 433 - 440
  • [3] BJARNGARD B E, 1976, Medical Physics (Woodbury), V3, P153, DOI 10.1118/1.594281
  • [4] CALCULATION OF ELECTRON-BEAM DEPTH-DOSE CURVES AND OUTPUT FACTORS FOR ARBITRARY FIELD SHAPES
    BRUINVIS, IAD
    MATHOL, WAF
    [J]. RADIOTHERAPY AND ONCOLOGY, 1988, 11 (04) : 395 - 404
  • [5] Choi M C, 1979, Med Phys, V6, P137, DOI 10.1118/1.594545
  • [6] LEVELS OF LEAKAGE RADIATION FROM ELECTRON COLLIMATORS OF A LINEAR-ACCELERATOR
    DAS, KR
    CRAMB, JA
    MILLAR, RM
    KENNY, MB
    PATTERSON, WR
    ACKERLY, TL
    PERKINS, AE
    CHONGKITIVITYA, K
    [J]. MEDICAL PHYSICS, 1990, 17 (06) : 1058 - 1063
  • [7] A MONTE-CARLO INVESTIGATION OF ELECTRON-BEAM APPLICATOR SCATTER
    EBERT, MA
    HOBAN, PW
    [J]. MEDICAL PHYSICS, 1995, 22 (09) : 1431 - 1435
  • [8] ELECTRON-BEAM DOSE CALCULATIONS
    HOGSTROM, KR
    MILLS, MD
    ALMOND, PR
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1981, 26 (03) : 445 - 459
  • [9] NUMERICAL-CALCULATION OF ENERGY DEPOSITION BY HIGH-ENERGY ELECTRON-BEAMS .3. 3-DIMENSIONAL HETEROGENEOUS MEDIA
    JANSSEN, JJ
    RIEDEMAN, DEJ
    MORAWSKAKACZYNSKA, M
    STORCHI, PRM
    HUIZENGA, H
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (09) : 1351 - 1366
  • [10] INFLUENCE OF CONE DESIGN ON THE ELECTRON-BEAM CHARACTERISTICS ON CLINICAL ACCELERATORS
    KASSAEE, A
    ALTSCHULER, MD
    AYYALSOMAYAJULA, S
    BLOCH, P
    [J]. MEDICAL PHYSICS, 1994, 21 (11) : 1671 - 1676