MASS-TRANSFER IN VARIOUS HOLLOW FIBER GEOMETRIES

被引:280
|
作者
WICKRAMASINGHE, SR [1 ]
SEMMENS, MJ [1 ]
CUSSLER, EL [1 ]
机构
[1] UNIV MINNESOTA,DEPT CHEM ENGN & MAT SCI,151 AMUNDSON HALL,421 WASHINGTON AVE SE,MINNEAPOLIS,MN 55455
基金
美国国家科学基金会;
关键词
MEMBRANE MODULES; MASS TRANSFER; BLOOD OXYGENATORS;
D O I
10.1016/0376-7388(92)80042-I
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Mass transfer coefficients in commercial modules, including blood oxygenators, agree with literature correlations at high flows but are smaller at low flows. The smaller values at low flows probably result from channelling in the hollow fiber bundle. For the special case of flow within the fibers, the slight polydispersity of the hollow fibers causing this channelling can be used to predict deviations from the Leveque limit. These deviations can not be predicted from extensions to the Leveque analysis, or the analysis by Graetz. For the special case of flow outside the fibers, the mass transfer coefficients in commercial modules of various geometries are surprisingly similar, and fall below those of carefully hand-made modules. These results can be used to develop still better membrane module designs.
引用
收藏
页码:235 / 250
页数:16
相关论文
共 50 条
  • [11] Modeling study on the mass transfer of hollow fiber renewal liquid membrane: Effect of the hollow fiber module scale
    Ren, Zhongqi
    Yang, Yanqiang
    Zhang, Weidong
    Liu, Junteng
    Wang, Houlin
    JOURNAL OF MEMBRANE SCIENCE, 2013, 439 : 28 - 35
  • [12] Mass-transfer in hollow-fiber modules for extraction and back-extraction of copper(II) with LIX64N carriers
    Lin, SH
    Juang, RS
    JOURNAL OF MEMBRANE SCIENCE, 2001, 188 (02) : 251 - 262
  • [13] MICROPOROUS HOLLOW-FIBER MEMBRANE MODULES AS GAS-LIQUID CONTACTORS .2. MASS-TRANSFER WITH CHEMICAL-REACTION
    KREULEN, H
    SMOLDERS, CA
    VERSTEEG, GF
    VANSWAAIJ, WPM
    JOURNAL OF MEMBRANE SCIENCE, 1993, 78 (03) : 217 - 238
  • [14] THE MONOD EQUATION AND MASS-TRANSFER
    MERCHUK, JC
    ASENJO, JA
    BIOTECHNOLOGY AND BIOENGINEERING, 1995, 45 (01) : 91 - 94
  • [15] Intensification of Mass Transfer in Hollow Fiber Modules by Adding Solid Particles
    Zhang, Weidong
    Chen, Geng
    Li, Jiang
    Liu, Junteng
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2009, 48 (18) : 8655 - 8662
  • [16] Mass transfer characteristics of cadmium(II) extraction in hollow fiber modules
    Wang, YJ
    Wang, Y
    Chen, F
    Luo, GS
    Dai, YY
    CHEMICAL ENGINEERING SCIENCE, 2003, 58 (14) : 3223 - 3231
  • [17] Mass transfer enhancement of hollow fiber membrane deoxygenation by Dean vortices
    Kong, Qing-ran
    Zhang, Yi-zhen
    Tian, Hua
    Fang, Li-feng
    Zhou, Ming-yong
    Zhu, Li-ping
    Zhu, Bao-ku
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE A, 2019, 20 (08): : 601 - 613
  • [18] Mass transfer of cadmium ions in a hollow-fiber module by pertraction
    Marchese, J
    Campderrós, M
    DESALINATION, 2004, 164 (02) : 141 - 149
  • [19] Mass transfer in hollow fiber module for reverse osmosis seawater desalination
    Iwahashi, H
    Kishi, M
    Miyatake, O
    KAGAKU KOGAKU RONBUNSHU, 2000, 26 (05) : 705 - 710
  • [20] A study of mass transfer in hollow-fiber membrane contactors - The effect of fiber packing fraction
    Asimakopoulou, A. G.
    Karabelas, A. J.
    JOURNAL OF MEMBRANE SCIENCE, 2006, 282 (1-2) : 430 - 441