Method Development and Validation for the Simultaneous Estimation of Rosuvastatin and Amlodipine in Bulk and its Formulation using Reverse-Phase High-Performance Liquid Chromatography

被引:0
|
作者
Boggula, Narender [1 ]
Mulagada, Gowri Manoja [1 ]
Priya, D. K. Shanthi [1 ]
Bakshi, Vasudha [1 ]
Peddapalli, Himabindu [1 ]
机构
[1] Anurag Grp Inst, Sch Pharm, Dept Pharmaceut Chem, Ghatkesar, Telangana, India
关键词
Amlodipine; precision; reverse-phase high-performance liquid chromatography; rosudapin; rosuvastatin; simultaneous estimation;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Background: High-performance liquid chromatography (HPLC) is basically a highly improved form of column liquid chromatography. Instead of a solvent being allowed to drip through a column under gravity, it is forced through under high pressures of up to 400 atmospheres which makes it much faster. All chromatographic separations including HPLC is based upon the resolution of the sample constituents as per the difference in their relative affinities towards stationary phase and mobile phase used. Aim: A simple, specific, accurate, and precise reverse-phase HPLC method was developed and validated for the estimation of rosuvastatin and amlodipine (Rosudapin) in pharmaceutical dosage form. Materials and Methods: An Aquasil column reversed phase C-18, 5 mu m column having 4.6 mm x 250 mm i. d. in gradient mode, with mobile phase containing HPLC grade acetonitrile: phosphate buffer (pH 3.8): methanol in proportion 30: 60: 10 v/v, was used. The flow rate was 1 ml/min and effluents were monitored at 251 nm using PDA detector. Linearity was observed over a range of 5-25 mu g/mL of rosuvastatin and 2.5-12.5 mu g/mL of amlodipine, respectively. Results and Discussion: The method was validated for linearity, accuracy, precision, limit of detection, limit of quantitation, robustness, and ruggedness. The limit of detection and estimation of analytes was found to be 3.1 mu g/ml and 2.98 mu g/ml, and the limit of quantification of analytes was found to be 102 mu g/ml and 9 mu g/ml, respectively, for rosuvastatin and amlodipine. Conclusion: The proposed method was successfully applied for the quantitative determination of rosuvastatin and amlodipine in pharmaceutical dosage form.
引用
收藏
页码:S1304 / S1309
页数:6
相关论文
共 50 条
  • [1] A New Reverse-Phase High Performance Liquid Chromatography Method for Simultaneous Estimation of Fimasartan, Rosuvastatin Calcium, and Amlodipine Besylate in Combination
    Rujuta Prashant Mistry
    Chainesh Shah
    Rakesh Jat
    Pharmaceutical Chemistry Journal, 2022, 56 : 416 - 420
  • [2] A New Reverse-Phase High Performance Liquid Chromatography Method for Simultaneous Estimation of Fimasartan, Rosuvastatin Calcium, and Amlodipine Besylate in Combination
    Mistry, Rujuta Prashant
    Shah, Chainesh
    Jat, Rakesh
    PHARMACEUTICAL CHEMISTRY JOURNAL, 2022, 56 (03) : 416 - 420
  • [3] Simultaneous estimation of atorvastatin and amlodipine by reverse phase high performance liquid chromatography
    Rajkondawar, V. V.
    ASIAN JOURNAL OF CHEMISTRY, 2006, 18 (04) : 3227 - 3229
  • [4] Simultaneous estimation of rosuvastatin and ezetimibe by reverse phase high performance liquid chromatography
    Rajkondawar, V. V.
    ASIAN JOURNAL OF CHEMISTRY, 2006, 18 (04) : 3230 - 3232
  • [5] Development and Validation of Analytical Method for Simultaneous Estimation of Tazarotene and Hydroquinone in their Gel Formulation by Reversed-phase High Performance Liquid Chromatography
    Yadav Yadav Rajkumar
    Yadav Divya
    Journal of Analytical Chemistry, 2019, 74 : 467 - 471
  • [6] Development and Validation of Analytical Method for Simultaneous Estimation of Tazarotene and Hydroquinone in their Gel Formulation by Reversed-phase High Performance Liquid Chromatography
    Rajkumar, Yadav
    Divya, Yadav
    Rakesh, Yadav
    JOURNAL OF ANALYTICAL CHEMISTRY, 2019, 74 (05) : 467 - 471
  • [7] Development and validation of simple simultaneous analysis for amlodipine and glibenclamide by nonderivatization high-performance liquid chromatography-fluorescence
    Saputri, Febrina Amelia
    Alawiyah, Anisahtul
    Firsty, Ayu Brilliany
    Megantara, Sandra
    Kusuma, Arif Satria Wira
    Rusdiana, Taofik
    Hasanah, Aliya Nur
    Mutakin, Mutakin
    Surono, Ingrid S.
    Abdulah, Rizky
    JOURNAL OF ADVANCED PHARMACEUTICAL TECHNOLOGY & RESEARCH, 2018, 9 (04) : 124 - 129
  • [8] Development and Validation of Reversed Phase High Performance Liquid Chromatographic Method for Determination of Amlodipine
    Alaama, Mohamed
    Uddin, A. B. M. Helal
    Mohamad, Huda Jamilah
    Amiruddin, Noor Syafawati
    Abbas, S. A.
    TROPICAL JOURNAL OF PHARMACEUTICAL RESEARCH, 2015, 14 (04) : 663 - 669
  • [9] METHOD DEVELOPMENT AND VALIDATION FOR SIMULTANEOUS ESTIMATION OF ALISKIREN AND ENALAPRIL IN BULK AND SYNTHETIC MIXTURE BY REVERSED PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHIC METHOD
    Sharma, Ishan R.
    Shah, Jignesh S.
    Maheswari, Dilip G.
    PHARMACOPHORE, 2014, 5 (02): : 239 - 245
  • [10] Development and Validation of Reversed Phase High Performance Liquid Chromatographic Method for Simultaneous Estimation of Paracetamol, Caffeine and Carisoprodol in Tablet Formulation
    Khanage, Shantaram G.
    Mohite, Popat B.
    Dharam, Prachi G.
    Deshmukh, Vinayak K.
    EURASIAN JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 10 (03): : 163 - 179