THE VALUE OF PLASMA CALIBRANTS IN CORRECTING COAGULOMETER EFFECTS ON INTERNATIONAL NORMALIZED RATIOS - AN INTERNATIONAL MULTICENTER STUDY

被引:64
作者
POLLER, L
TRIPLETT, DA
HIRSH, J
CARROLL, J
CLARKE, K
机构
[1] BALL MEM HOSP,MUNCIE,IN 47303
[2] HAMILTON CIV HOSP,RES CTR,HAMILTON,ON,CANADA
[3] ORTHO DIAGNOST SYST INC,RARITAN,NJ
关键词
PROTHROMBIN TIME; COAGULATION TESTS; LABORATORY STANDARDIZATION; WARFARIN;
D O I
10.1093/ajcp/103.3.358
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
A study of lyophilized plasma calibrants in correcting for coagulometer effects on International Normalized Ratios (INR) has been conducted in an international survey. Prothrombin times were performed with the calibrants on 2 ''common'' thromboplastins and in-house thromboplastins in 3 brands of coagulometer at 37 centers. The International Sensitivity Indices (ISI) of 95 local systems with the calibrants were derived. The ''true'' INR of 10 test plasmas from warfarin-treated patients were established centrally using thromboplastin International Reference Preparations (IRP). International Normalized Ratios of these plasmas for each center were calculated using both the manufacturers' stated and the local ISI. The mean deviation of the 95 systems from the ''true'' INR of the, warfarin plasmas was +14.4% with the manufacturers' ISI, but reduced to +1.04% with the local ISI. Local ISI determination with the calibrants avoids many of the difficulties of conventional thromboplastin calibrations. Plasmas from patients on warfarin and parallel manual PT with thromboplastin IRP are not required.
引用
收藏
页码:358 / 365
页数:8
相关论文
共 12 条
  • [1] ASSESSMENT OF VALUE OF CALIBRATED LYOPHILIZED PLASMAS TO DETERMINE INTERNATIONAL SENSITIVITY INDEX FOR COAGULOMETERS
    CLARKE, K
    TABERNER, DA
    THOMSON, JM
    MORRIS, JA
    POLLER, L
    [J]. JOURNAL OF CLINICAL PATHOLOGY, 1992, 45 (01) : 58 - 60
  • [2] COMPARISON OF 2 AUTOMATED COAGULOMETERS AND THE MANUAL TILT-TUBE METHOD FOR THE DETERMINATION OF PROTHROMBIN TIME
    DANGELO, A
    SEVESO, MP
    DANGELO, SV
    GILARDONI, F
    MACAGNI, A
    MANOTTI, C
    BONINI, P
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1989, 92 (03) : 321 - 328
  • [3] HERMANS J, 1984, THROMBOPLASTIN CALIB, P41
  • [4] POGGIO M, 1988, THROMB HAEMOSTASIS, V62, P868
  • [5] EFFECT OF THE CHOICE OF WHO INTERNATIONAL REFERENCE PREPARATION FOR THROMBOPLASTIN ON INTERNATIONAL NORMALIZED RATIOS
    POLLER, L
    TABERNER, DA
    THOMSON, JM
    MORRIS, J
    MIBASHAN, RS
    SHINTON, NK
    [J]. JOURNAL OF CLINICAL PATHOLOGY, 1993, 46 (01) : 64 - 66
  • [6] EFFECT OF AUTOMATION ON PROTHROMBIN TIME TEST IN NEQAS SURVEYS
    POLLER, L
    THOMSON, JM
    TABERNER, DA
    [J]. JOURNAL OF CLINICAL PATHOLOGY, 1989, 42 (01) : 97 - 100
  • [7] THE CORRECTION OF COAGULOMETER EFFECTS ON INTERNATIONAL NORMALIZED RATIOS - A MULTICENTER EVALUATION
    POLLER, L
    THOMSON, JM
    TABERNER, DA
    CLARKE, DK
    [J]. BRITISH JOURNAL OF HAEMATOLOGY, 1994, 86 (01) : 112 - 117
  • [8] RAY MJ, 1990, THROMB HAEMOSTASIS, V63, P424
  • [9] Schmidt Nico A, 1989, CLIN CHEM, V355, P840
  • [10] AUTOMATION AND PROTHROMBIN TIME - A UNITED-KINGDOM FIELD-STUDY OF 2 WIDELY USED COAGULOMETERS
    THOMSON, JM
    TABERNER, DA
    POLLER, L
    [J]. JOURNAL OF CLINICAL PATHOLOGY, 1990, 43 (08) : 679 - 684